G2RL-1-H-DC12 Omron, G2RL-1-H-DC12 Datasheet - Page 2

General Purpose / Industrial Relays SPDT 12 VDC

G2RL-1-H-DC12

Manufacturer Part Number
G2RL-1-H-DC12
Description
General Purpose / Industrial Relays SPDT 12 VDC
Manufacturer
Omron
Series
G2RLr
Datasheet

Specifications of G2RL-1-H-DC12

Contact Form
SPST - NO
Coil Voltage
12 V
Contact Rating
16 A at 250 VAC
Mounting Style
Through Hole
Power Consumption
400 mW
Contact Material
Silver Alloy
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
G2RL-TP
Specifications
Note: The rated current and coil resistance are measured at a coil temperature of 23 ° C with a tolerance of 10%.
Note: P level: λ 60=0.1 x 10
Note: Values in the above table are the initial values.
UL508 (File No. E41643)/CSA C22.2 (No.14) (File No. LR31928)
VDE (EN61810-1): (License No. 119650)
2
Rated voltage
Rated current
Coil resistance
Must operate voltage
Must release voltage
Max. voltage
Power consumption
Contact material
Load
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Max. switching power
Contact resistance
Operate time
Release time
Max. operating frequency
Insulation resistance
Dielectric strength
Impulse withstand voltage
Vibration resistance
Shock resistance
Endurance
Ambient temperature
Ambient humidity
Weight
G2RL-1ATP7-E
G2RL-1ATP5-E
G2RL-1ATP7-E
G2RL-1ATP5-E
Coils Ratings
Contact Ratings
Characteristics
Approved Standards
Model
Model
-6
operations
SPST-NO (High capacity)
SPST-NO (High capacity)
Contact form
Contact form
Ag alloy (Cd free)
Resistive load (cos φ =1)
16 A at 250 VAC
16 A
440 VAC
16 A
4,000 VA
100 m Ω max.
15 ms max.
5 ms max.
Mechanical: 18,000 operations/hr
Electrical:
1,000 M Ω min. (at 500 VDC)
5,000 VAC, 1 min between coil and contacts
1,000 VAC, 1 min between contacts of same polarity
10 kV (1.2 × 50 µ s) between coil and contact
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Destruction: 1,000 m/s
Malfunction: Energized:100 m/s
Mechanical: 20,000,000 operations min. (at 18,000 operations/hr)
Electrical:
–40 to 105 ° C (with no icing)
5% to 85%
Approx. 12 g
12 VDC
33.3 mA
360 Ω
70% max. of the rated voltage
10% min. of the rated voltage
130% at 105 ° C of the rated voltage
Approx. 400 mW
900 operations/hr at rated load
Not energized:100 m/s
50,000 operations min. (at 900 operations/hr)
2
12 to 24 VDC
12, 24 VDC
Coil ratings
Coil ratings
2
2
24 VDC
16.7 mA
1,440 Ω
16 A at 250 VAC (General use)
16 A at 24 VDC (Resistive)
16 A at 250 VAC (Resistive), 105 ° C,
100,000 operations
16 A at 250 VAC (cos φ =1), 105 ° C,
100,000 operations
Contact ratings
Contact ratings
G2RL-TP