G6A-234P-ST-US-DC12 Omron, G6A-234P-ST-US-DC12 Datasheet - Page 2

Low Signal Relays - PCB STANDARD DPDT 12VDC

G6A-234P-ST-US-DC12

Manufacturer Part Number
G6A-234P-ST-US-DC12
Description
Low Signal Relays - PCB STANDARD DPDT 12VDC
Manufacturer
Omron
Series
G6A2r

Specifications of G6A-234P-ST-US-DC12

Coil Type
Non-Latching
Coil Current
16.7 mA
Contact Form
2 Form C
Coil Voltage
12 VDC
Power Consumption
200 mW
Termination Style
Solder Pin
Maximum Switching Current
2 A
Contact Rating
0.30 A at 125 VAC, 1 A at 30 VDC
Contact Configuration
DPDT
Contact Current Max
2A
Contact Voltage Ac Nom
125V
Contact Voltage Dc Nom
30V
Coil Voltage Vdc Nom
12V
Current, Rating
0.3⁄1 AAC⁄ADC
Diameter, Mounting
0.04 in.
Dielectric Rating
1,000 VAC, 50⁄60 Hz for 1 minute between coil and contacts, 1,000 VAC, 50⁄60 Hz for 1 minute between contacts of different poles, 1,000 VAC, 50⁄60 Hz for 1 minute between contacts of same pole, 250 VAC, 50⁄60 Hz for 1 minute between set and reset coils
Dimensions
0.80 in. (Max.) L x 0.40 in. (Max.) W x 0.33 in. (Max.) H
Function
Sensitive
Material, Contact
AgPd (Au Clad)
Mounting Type
PCB
Number Of Pins
8
Power, Rating
125⁄60 VA⁄W
Relay Type
Electro Mechanical
Standards
UL, CSA
Temperature, Operating, Maximum
70 °C
Temperature, Operating, Minimum
-40 °C
Termination
Solder
Voltage, Control
12 VDC
Voltage, Rating
125 VAC
Coil Resistance
720ohm
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G6A-234P-ST-US-DC12V
Manufacturer:
OMRON
Quantity:
12 000
Specifications
■ Contact Data
■ Coil Data
Standard Non-latching DPDT (G6A-234P-ST-US, G6A-274P-ST-US)
High-sensitivity Non-latching DPDT (G6A-234P-ST15-US, G6A-274P-ST15-US)
Note: The rated current and coil resistance are measured at a coil temperature of 23° C (73° F) with a tolerance of ±10%.
2
Type
Load
Rated load
Contact material
Carry current
Max. operating voltage
Max. operating current
Max. switching capacity
Min. permissible load
3
5
6
9
12
24
48
1.50
3
4.50
5
6
9
12
24
48
voltage
voltage
Rated
(VDC)
Rated
(VDC)
Low Signal Relay
66.70
40
33.30
22.20
16.70
8.30
4.90
100
50
33.30
30
25
16.70
12.50
6.30
3.20
current
current
Rated
Rated
(mA)
(mA)
0.30 A at 125 VAC,
1 A at 30 VDC
AgPd (Au clad)
3 A
250 VAC, 220 VDC
2 A
125 VA, 60 W
10 µA, 10 mVDC
Resistive load (p.f. = 1)
G6A-234P-ST(15,40)-US, G6A-434P-ST(20,40)-US
45
125
180
405
720
2,880
9,750
15
60
135
167
240
540
960
3,840
15,000
G6AK-234P-ST(40)-US, G6AK-434P-ST(40)-US
resistance
resistance
G6A
G6AU-234P-ST-US, G6AU-434P-ST-US
Coil
Coil
(Ω)
(Ω)
0.07
0.20
0.29
0.63
1.10
4.50
13.70
0.02
0.09
0.22
0.25
0.35
0.80
1.35
5.60
22.50
Armature
Armature
OFF
OFF
Coil inductance
Coil inductance
(ref. value) (H)
(ref. value) (H)
0.20 A at 125 VAC,
0.50 A at 30 VDC
AgPd (Au clad)
3 A
250 VAC, 220 VDC
1 A
62.50 VA, 30 W
10 µA, 10 mVDC
Inductive load (p.f. = 0.4)
0.07
0.18
0.26
0.57
1.06
4.10
12.50
0.02
0.08
0.20
0.21
0.31
0.70
1.25
5.10
20.00
(L/R = 7 ms)
Armature
Armature
ON
ON
70% max.
80% max.
Pick-up
voltage
Pick-up
voltage
0.50 A at 125 VAC,
2 A at 30 VDC
Ag (Au clad)
3 A
250 VAC, 220 VDC
2 A
125 VA, 60 W
10 µA, 10 mVDC
Resistive load (p.f. = 1)
G6A-274P-ST(15,40)-US, G6A-474P-ST(20,40)-US
G6AK-274P-ST(40)-US, G6AK-474P-ST(40)-US
% of rated voltage
% of rated voltage
G6AU-274P-ST-US, G6AU-474P-ST-US
10% min.
10% min.
Dropout
Dropout
voltage
voltage
200%
at 23°C
(73°F)
150%
at 70°C
(158°F)
200%
Maximum
Maximum
0.25 A at 125 VAC,
1 A at 30 VDC
Ag (Au clad)
3 A
250 VAC, 220 VDC
1 A
62.50 VA, 30 W
10 µA, 10 mVDC
voltage
voltage
Inductive load (p.f. = 0.4)
(L/R = 7 ms)
Approx. 200
Approx. 235
Approx. 150
consumption
consumption
Power
Power
(mW)
(mW)

Related parts for G6A-234P-ST-US-DC12