Low Signal Relays - PCB DPDT PCB 5VDC

G5V-2-H1-DC5

Manufacturer Part Number
G5V-2-H1-DC5
Description
Low Signal Relays - PCB DPDT PCB 5VDC
Manufacturer
Omron
Series
G5V2r
Datasheets

Specifications of G5V-2-H1-DC5

Contact Form
2 Form C
Coil Voltage
5 VDC
Coil Current
72 mA
Coil Type
Non-Latching
Power Consumption
150 mW
Termination Style
Solder Pin
Maximum Switching Current
2 A
Contact Rating
0.50 A at 125 VAC, 2 A at 30 VDC
Current, Rating
0.5⁄1 AAC⁄ADC
Diameter, Mounting
0.039 in. Dia. (Hole)
Dielectric Rating
1000 VAC @ 50⁄60 Hz for 1 minute between coil and contacts
Dimensions
0.807 in. L x 0.398 in. W x 0.453 in. H
Function
Sensitive
Material, Contact
Ag (Au clad)
Number Of Pins
8
Power, Rating
62.5⁄24 VA⁄W
Relay Type
Electro Mechanical
Standards
UL, CSA, FCC, RoHS
Temperature, Operating, Maximum
70 °C
Temperature, Operating, Minimum
-25 °C
Voltage, Control
5 VDC
Voltage, Rating
125 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G5V2H15DC OMRG5V2H15DC

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G5V-2-H1-DC5V
Manufacturer:
OMRON
Quantity:
12 000
Part Number:
G5V-2-H1-DC5V
Manufacturer:
OMRON
Quantity:
20 000
Part Number:
G5V-2-H1-DC5V
Manufacturer:
OMRON/欧姆龙
Quantity:
20 000
Company:
Part Number:
G5V-2-H1-DC5V
Quantity:
5 655
■ Characteristics
Note: Data shown are of initial value.
■ Characteristic Data
Contact resistance
Operate time
Release time
Bounce time
Operating frequency
Insulation resistance
Dielectric strength
Surge withstand voltage
Vibration
Shock
Ambient temperature
Humidity
Service life
Weight
Maximum Switching Capacity
Rated operating voltage (V)
Operate
Release
Mechanical
Electrical
Mechanical durability 10 to 55 Hz, 1.50 mm (0.59 in) double amplitude
Malfunction durability
Mechanical durability 1,000 m/s
Malfunction durability 200 m/s
Operating/storage
Mechanical
Electrical
Electrical Service Life
50 mΩ max. G5V-2, G5V-2-H, 100 mΩ max. G5V-2-H1
7 ms max. (mean value: approx. 3.5 ms)
3 ms max. (mean value: approx. 0.8 ms)
Mean value: approx. 0.5 ms
Mean value: approx. 3.5 ms
36,000 operations/hour
1,800 operations/hour (under rated load)
1,000 MΩ min (at 500 VDC)
1,000 VAC, 50/60 Hz for 1 minute between coil and contacts
1,000 VAC, 50/60 Hz for 1 minute between contacts of different poles
750 VAC, 50/60 Hz for 1 minute between contacts of same poles
(500 VAC, 50/60 Hz for 1 minute between contacts of same poles for ultra-sensitive type)
1,500 V 10 X 160 µs (conforms to part 68 of FCC rules)
-25° to 70°C (-13° to 158°F)
35% to 85% RH
15 million operations min. (at operating frequency of 36,000 operations/hour)
See “Characteristic Data”
6 g (0.21 oz)
Rated operating current (A)
2
(approx. 20 G), 100 m/s
2
(approx. 100 G)
2
(approx. 10 G) for ultra-sensitive type
Low Signal Relay
Ambient Temperature vs. Maximum Voltage
— 48 VDC coil voltage (standard type)
— All other types and voltages
Rated operating current (A)
G5V-2
3