J114D-26M TELEDYNE, J114D-26M Datasheet - Page 2

RF (Radio Frequency) Relays DPDT 26.5VDC 1560 ohm w/diode

J114D-26M

Manufacturer Part Number
J114D-26M
Description
RF (Radio Frequency) Relays DPDT 26.5VDC 1560 ohm w/diode
Manufacturer
TELEDYNE
Series
114r
Datasheet

Specifications of J114D-26M

Contact Form
2 Form C (DPDT)
Coil Voltage
26.5 VDC
Termination Style
PCB
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
114 Page 2
SERIES 114
GENERAL ELECTRICAL SPECIFICATIONS (–65°C to +125°C unless otherwise noted) (Notes 2 & 3)
DETAILED ELECTRICAL SPECIFICATIONS (–65°C to +125°C unless otherwise noted) (Note 3)
PERFORMANCE CURVES
(NOTE 2)
Contact Arrangement
Rated Duty
Contact Resistance
Contact Load Ratings (DC)
(See Fig. 2 for other DC
resistive voltage/current ratings)
Contact Load Ratings (AC)
Contact Life Ratings
Contact Overload Rating
Contact Carry Rating
Operate Time
Release Time
Contact Bounce
Intercontact Capacitance
Insulation Resistance
Dielectric Strength
Negative Coil Transient (Vdc)
Diode P.I.V. (Vdc)
Coil Voltage (Vdc)
Coil Resistance
(Ohms ±10% @25°C)
Coil Current (mAdc @25°C)
(114DD Series)
Pick-up Voltage (Vdc, Max.)
Drop-out Voltage (Vdc)
10
20
30
40
50
60
70
.1
.2
.3
.4
0
.01
TYPICAL RF PERFORMANCE
0.5
FREQUENCY (GHz)
(See Note 8 for full P/N example)
FIGURE 1
.1
114, 114D
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
114DD
2 Form C (DPDT)
Continuous
0.1 ohm max. before life; 0.2 ohm max. after life at 1A/28Vdc (measured 1/8" from header)
Resistive:
Inductive:
Lamp:
Low Level:
Resistive:
10,000,000 cycles (typical) at low level
2A/28Vdc Resistive (100 cycles min.)
Contact factory
2.0 msec max. at nominal rated coil voltage
114 Series: 1.5 msec max.
1.5 msec max.
0.4 pf typical
10,000 megohms min. between mutually isolated terminals
Atmospheric pressure: 500 Vrms/60Hz
1,000,000 cycles (typical) at 0.5A/28Vdc resistive
100,000 cycles min. at all other loads specified above
114D, 114DD
114D, 114DD
BASE PART
.5
114DD (Note 4)
NUMBERS
114, 114D
114, 114D
114DD
1.0
Nom.
Max.
1.92
1.22
1.07
1.02
1.01
1.00
1.00
1 Amp/28Vdc
200 mA/28Vdc (320 mH)
100 mA/28Vdc
10 to 50 μA/10 to 50mV
250 mA/115Vac, 60 and 400 Hz (Case not grounded)
100 mA/115Vac, 60 and 400 Hz (Case grounded)
Max.
Max.
Max.
Min.
Min.
Min.
www.teledynerelays.com
114D, 114DD Series: 4.0 msec max.
114DD-5
114D-5
114-5
128.2
93.2
0.14
5.0
5.8
3.5
4.0
2.3
0.6
2.8
50
39
300
250
200
150
100
50
0
114DD-6
114D-6
0.1
114-6
58.3
78.3
0.18
6.0
8.0
4.5
5.0
3.2
0.7
3.4
98
78
0.2
TYPICAL DC CONTACT RATING (RESISTIVE)
114DD-9
114D-9
0.3
114-9
12.0
33.0
42.9
0.35
220
220
9.0
6.8
7.8
4.9
0.8
5.3
LOAD CURRENT (AMPS DC)
70,000 ft.: 125 Vrms/60Hz
0.4
FIGURE 2
114DD-12
114D-12
0.5
114-12
12.0
16.0
25.6
32.8
10.0
0.41
390
390
9.0
6.5
0.9
6.5
0.6
©2006 TELEDYNE RELAYS
100 min.
1.0 max
114DD-18
114D-18
0.7
114-18
18.0
24.0
17.5
22.1
13.5
14.5
0.59
10.0
10.0
880
880
1.1
0.8
114DD-26
114D-26
114/0706/Q1
0.9
114-26
1560
1560
26.5
32.0
14.8
18.5
18.0
19.0
0.89
13.0
13.0
1.4
1.0

Related parts for J114D-26M