E2E-CR8C1

Manufacturer Part Number
E2E-CR8C1
Description
Proximity Sensors INDUCTIVE 4MM NPN
Manufacturer
Omron
Type
Inductive Proximity Sensorr
Series
E2Er
Datasheets

Specifications of E2E-CR8C1

Maximum Operating Temperature
+ 70 C
Supply Voltage
10 V to 30 V
Supply Current
17 mA
Operating Supply Voltage
10 V to 30 V
Mounting Style
Cable
Minimum Operating Temperature
- 25 C
Maximum Output Current
100 mA
Features
High visibility indicator
Sensing Distance
0.8 mm
Sensor Input
Inductive
Sensing Range
0.8mm
Supply Voltage Range Dc
10V To 30V
Mounting Type
Panel
Switch Terminals
Cable
Load Current Rms Max
100mA
Sensing Face Diameter
4mm
Supply Voltage Min
10VDC
Sensor Type
Inductive
Sensing Object
Metallic
Response Frequency
3kHz
Material - Body
Stainless Steel
Shielding
Shielded
Voltage - Supply
10 V ~ 30 V
Output Type
NPN-NO
Terminal Type
3-Wire
Package / Case
Cylinder
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
E2E 3-Wire DC
Precautions
J INSTALLATION
Power Reset Time
The Proximity Sensor is ready to operate within 100 ms after power
is supplied. If power supplies are connected to the Proximity Sensor
and load respectively, be sure to supply power to the Proximity Sen-
sor before supplying power to the load.
Power OFF
The Proximity Sensor may output a pulse signal when it is turned off.
You must turn off the load before turning off the Proximity Sensor.
Power Supply Transformer
When using a DC power supply, make sure that the DC power sup-
ply has an insulated transformer. Do not use a DC power supply with
an auto-transformer.
Sensing Object
Metal Coating
The sensing distances of the Proximity Sensor vary with the metal
coating on sensing objects.
J WIRING
High-tension Lines
Wiring through Metal Conduit
If there is a power or high-tension line near the cable of the Proximi-
ty Sensor, wire the cable through an independent metal conduit to
prevent against Proximity Sensor damage or malfunctioning.
Cable Tractive Force
Do not pull cable with the tractive forces exceeding the following.
J MOUNTING
The Proximity Sensor must not be subjected to excessive shock
with a hammer when it is installed, or the Proximity Sensor may be
damaged or lose its water-resistance.
J ENVIRONMENT
Water Resistance
Do not use the Proximity Sensor underwater, outdoors, or in the
rain.
Operating Environment
Be sure to use the Proximity Sensor within its operating ambient
temperature range and do not use the Proximity Sensor outdoors so
that its reliability and life expectancy can be maintained. Although
the Proximity Sensor is water resistant, a cover to protect the Prox-
imity Sensor from water or water-soluble machining oil is recom-
mended so that its reliability and life expectancy can be maintained.
Do not use the Proximity Sensor in an environment with chemical
gas (e.g., strong alkaline or acid gasses including nitric, chromic,
and concentrated sulfuric acid gases).
Diameter
4 mm dia. max.
4 mm dia. min.
16
Tractive force
30 N max.
50 N max.
E2E 3-Wire DC

Related parts for E2E-CR8C1