30080 Parallax Inc, 30080 Datasheet

Vibration & Tilt Sensors Say it Module

30080

Manufacturer Part Number
30080
Description
Vibration & Tilt Sensors Say it Module
Manufacturer
Parallax Inc
Series
-r
Datasheet

Specifications of 30080

Mounting Style
Vertical
Main Purpose
Audio, Voice Recognition
Embedded
-
Utilized Ic / Part
-
Primary Attributes
23 Pre-Programmed Speaker Independent (SI) Commands
Secondary Attributes
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
30080
Manufacturer:
NS
Quantity:
5 510
Part Number:
30080
Manufacturer:
NEC
Quantity:
5 510
Part Number:
300800
Quantity:
8
Part Number:
3008002
Quantity:
52
Part Number:
300800202
Quantity:
7
Parallax Say It Module (#30080)
The Parallax Say It Modules provides voice recognition functions for built-in Speaker Independent (SI)
pre-programmed commands and up to 32 user-defined Speaker Dependent (SD) keywords (triggers,
commands, or passwords).
When you speak into this module, it will match the spoken word to a set of keywords that it has been
programmed to recognize. Once the module has determined if there is a match, it will take a defined
action, either listening for the next keyword in another “wordset” or executing the commands associated
with the word that was said. You can create up to 32 user-definable keywords.
The Say It GUI software for the BASIC Stamp 2 provides an easy interface for training the module and
producing template code. Or, the simple and robust serial protocol provided can be used to access the
Say It module functions from other Parallax microcontrollers. The 10-pin SIP header makes the module
breadboard friendly, and is designed to fit in one row of the AppMod header found on the Board of
Education and Boe-Bot Robot.
Features
Key Specifications
Application Ideas
Precaution
Copyright © Parallax Inc.
23 Pre-programmed commands
Up to 32 user-definable commands
SIP for breadboard friendly projects (0.1” spacing)
GUI provides training and template code for BASIC Stamp 2
modules
On-board LED and microphone
Voice controlled Boe-Bot examples
Power requirements: 3.3 to 5.5 VDC
Communication: Adjustable Asynchonous Serial (9600 (default),
19200, 38700, 57600, 115200)
Operating temperature: 32 to 158 °F (0 to 70 °C)
Dimensions: 1.02 x 2.47 x .38 in (26 x 62.93 x 9.70 mm)
Voice-controlled entry systems
Automated house applications
Voice-activated robotics
Do not solely rely on the Say It module to recognize a command for a safety stop if your project
requires one; take all appropriate precautions when implementing this module to maintain a safe
project.
Parallax Say It Module (#30080)
Web Site: www.parallax.com
Forums: forums.parallax.com
Sales: sales@parallax.com
Technical: support@parallax.com
v1.0 4/14/2010 Page 1 of 19
Office: (916) 624-8333
Fax: (916) 624-8003
Sales: (888) 512-1024
Tech Support: (888) 997-8267

Related parts for 30080

30080 Summary of contents

Page 1

... Copyright © Parallax Inc. Web Site: www.parallax.com Forums: forums.parallax.com Sales: sales@parallax.com Technical: support@parallax.com Parallax Say It Module (#30080) Office: (916) 624-8333 Fax: (916) 624-8003 Sales: (888) 512-1024 Tech Support: (888) 997-8267 v1.0 4/14/2010 Page ...

Page 2

... Vdd at bottom P0 and LED to P4). 2. Download and install the Say It GUI software from the 30080 product page at www.parallax.com. Use the default installation path. For Windows Vista users, install as administrator. 3. Start the Say It GUI software, and then connect the Board of Education to your PC and turn the power switch on (position 1) ...

Page 3

... A PBASIC “bridge” program will automatically be downloaded to the BASIC Stamp 2. This bridge program allows the user to work with the set of SI commands the Say It module provides, as well as defining new commands. Copyright © Parallax Inc. Serial port to use Connect Icon Figure 2 Figure 3 Parallax Say It Module (#30080) v1.0 4/14/2010 Page ...

Page 4

... Copyright © Parallax Inc. Wordset 1 Wordset 2 0 action 0 left 1 move 1 right 2 turn run 3 down 4 look 4 forward 5 attack 5 backward 6 stop 7 hello Figure 4 Parallax Say It Module (#30080) Wordset 3 0 zero 1 one 2 two 3 three 4 four 5 five 6 six 7 seven 8 eight 9 nine 10 ten v1.0 4/14/2010 Page ...

Page 5

... Group – Groups of user-definable SD commands. You may add commands total (31 if you also define a trigger word).  Password – A special group for “vocal passwords,” may be defined.  Wordset – Built-in groups of Speaker Independent (SI) commands (Figure 3) Copyright © Parallax Inc. Test Group Figure 5 Parallax Say It Module (#30080) v1.0 4/14/2010 Page ...

Page 6

... Adding a SD command can be completed by doing the following while the Say It “bridge” program is running. 1. Select a group that you would like to add the word(s) to (Figure 6). Copyright © Parallax Inc. Figure 6 Parallax Say It Module (#30080) v1.0 4/14/2010 Page ...

Page 7

... Click “Add Command” from the tool bar or menu (Figure 7), and provide a label. In this example, the label “CREATE_LABEL_HERE” has been created; however it is suggested that you use a label that you can later review and know what the word is. Copyright © Parallax Inc. Add Command Figure 7 Parallax Say It Module (#30080) v1.0 4/14/2010 Page ...

Page 8

... If you are unhappy with the training, select erase training, and start the training process over from step 3 until satisfied. Copyright © Parallax Inc. Train Command Figure 8 Parallax Say It Module (#30080) v1.0 4/14/2010 Page ...

Page 9

... Once finished you will see a number next to the group you trained; indicating how many words belong to that group (Figure 9). Copyright © Parallax Inc. Figure 9 Figure 10 Parallax Say It Module (#30080) v1.0 4/14/2010 Page ...

Page 10

... Select the “Generate Code…” icon on the toolbar or from the menu (Figure 11) 2. You will be prompted to save the file to then edit within the BASIC Stamp Editor (Figure 12). Copyright © Parallax Inc. Generate Code Figure 11 Parallax Say It Module (#30080) v1.0 4/14/2010 Page ...

Page 11

... Vdd at bottom P0 and LED to P4). 2. Open the sample code labeled “SayIt_Demo.BS2” in the BASIC Stamp Editor. Copyright © Parallax Inc. Figure 12 Parallax Say It Module (#30080) ® Robot v1.0 4/14/2010 Page ...

Page 12

... Parallax Say It Module (#30080) v1.0 4/14/2010 Page ...

Page 13

... Copyright © Parallax Inc. Quantity Minimum 3.3 Function Ground Receive I/O Pin (TTL & CMOS compatible) Transmit I/O Pin (TTL & CMOS compatible) Red LED indicator No Connection No Connection Parallax Say It Module (#30080) Say It module back connection Typical Maximum 5.0 5.5 v1.0 4/14/2010 Page Units V ...

Page 14

... This is the back view of the module, the connection pins are indicated on the silkscreen. 5 VDC (Pin 10) no connect x no connect x no connect x no connect x no connect x Indicator LED Transmit pin Receive pin Ground (Pin 1) Module Dimensions 13.20 mm Copyright © Parallax Inc. No Connection No Connection No Connection 5 V regulated DC Parallax Say It Module (#30080) 63.22 mm v1.0 4/14/2010 Page ...

Page 15

... Knob level (0-4) Expected replies: STS_SUCCESS CMD_LEVEL “v” Sets Speaker Dependent (custom programmed commands) to specific level [1] Threshold (1-5) Expected replies: STS_SUCCESS CMD_LANGUAGE “l” Set Speaker Independent (pre-programmed commands) language Copyright © Parallax Inc. Parallax Say It Module (#30080) 26.21 mm v1.0 4/14/2010 Page ...

Page 16

... Remove Speaker Dependent (custom command) or Password recognition [1] Command position (0-31) Expected replies: STS_SUCCESS CMD_NAME_SD Give a label for a Speaker Dependent (custom programmed commands) or Password “n” command [1] Group index (0 = trigger, 1-15 = generic password [2] Command position (0-31) Copyright © Parallax Inc. Parallax Say It Module (#30080) v1.0 4/14/2010 Page ...

Page 17

... Expected replies: STS_SUCCESS Status Details STS_MASK “k” Mask of non-empty groups [1-8] 4-bit value that form a 32-bit mask, LSB first In replay to: CMD_MASK_SD STS_COUNT “c” Count of commands [1] Integer (0-31) In replay to: CMD_COUNT_SD Copyright © Parallax Inc. Parallax Say It Module (#30080) v1.0 4/14/2010 Page ...

Page 18

... Recognized Speaker Independent (pre-programmed commands) work or training a similar “s” Speaker Independent (pre-programmed commands) command [1] Wordset indext (0-31) In replay to: CMD_RECOG_SD, CMD_TRAIN_SD,CMD_RECOG_SI STS_OUT_OF_MEM “m” Memory Full Error In replay to: CMD_GROUP_SD STS_ID “x” Provide firmware ID Copyright © Parallax Inc. Parallax Say It Module (#30080) v1.0 4/14/2010 Page ...

Page 19

... Version ID (0) In replay to: CMD_ID Argument Mapping ARG_MIN “@” Minimum argument value (-1) ARG_MAX “ ‘ “ Maximum argument value (-1) ARG_ZERO “A” Zero argument value Copyright © Parallax Inc. Parallax Say It Module (#30080) v1.0 4/14/2010 Page ...

Related keywords