UVQ-48/2.5-D48N-C Murata Power Solutions Inc, UVQ-48/2.5-D48N-C Datasheet

DC/DC Converters & Regulators 120W 48 Vin/out 2.5A NEGATIVE POLARITY

UVQ-48/2.5-D48N-C

Manufacturer Part Number
UVQ-48/2.5-D48N-C
Description
DC/DC Converters & Regulators 120W 48 Vin/out 2.5A NEGATIVE POLARITY
Manufacturer
Murata Power Solutions Inc
Datasheet

Specifications of UVQ-48/2.5-D48N-C

Output Power
120 W
Input Voltage Range
36 V to 75 V
Number Of Outputs
1
Output Voltage (channel 1)
48 V
Output Current (channel 1)
2.5 A
Isolation Voltage
2.25 KV
Product
Isolated
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
UVQ-48/2.5-D48N-C

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UVQ-48/2.5-D48N-C
Manufacturer:
MURATA/村田
Quantity:
20 000
FEATURES
www.murata-ps.com
Typical unit
www.murata-ps.com/rohs
 
CONTROL*
Baseplate
REMOTE
Optional
ON/OFF
(9)
(2)
+V
–V
(3)
(1)
IN
IN
INPUT UNDERVOLTAGE, INPUT
OVERVOLTAGE, AND OUTPUT
OVERVOLTAGE COMPARATORS
PRODUCT OVERVIEW
www.murata-ps.com
CONTROLLER
Contents
Figure 1. Simplifi ed Schematic
PWM
Typical confi guration — some models use a different topology
* Can be ordered with positive (standard) or negative (optional) polarity.
ISOLATION
CONTROL
SWITCH
OPTO
22 Feb 2011 MDC_UVQ Models.B18
REFERENCE &
ERROR AMP
email: sales@murata-ps.com
UVQ Series
Page
+SENSE
+V
–V
–SENSE
TRIM
V
(8)
(4)
(7)
OUT
(6)
OUT
(5)
OUT

Related parts for UVQ-48/2.5-D48N-C

UVQ-48/2.5-D48N-C Summary of contents

Page 1

... Typical confi guration — some models use a different topology Figure 1. Simplifi ed Schematic www.murata-ps.com UVQ Series Page SWITCH CONTROL OPTO REFERENCE & ISOLATION ERROR AMP * Can be ordered with positive (standard) or negative (optional) polarity. email: sales@murata-ps.com 22 Feb 2011 MDC_UVQ Models.B18 +SENSE (7) +V OUT (8) –V OUT (4) –SENSE (5) V OUT ...

Page 2

... UVQ-1.5/40-D24P-C UVQ-2.5/35-D24P-C UVQ-2.5/40-D48N-C ➁ UVQ-3.3/30-D24P-C ➁ UVQ-3.3/35-D48N-C UVQ-5/20-D24P-C UVQ-5/20-D48N-C UVQ-12/8-D24P-C UVQ-12/10-D48N-C UVQ-15/7-D24P-C UVQ-15/7-D48N-C UVQ-18/5.6-D24P-C UVQ-18/6-D48N-C UVQ-24/4.5-D24P-C UVQ-24/4.5-D48N-C UVQ-48/2.5-D24P-C UVQ-48/2.5-D48N Model UVQ-31128-C UVQ Pin 9 Baseplate Connection ➀ Output ➂ R/N (mVp-p) Regulation (Max.) V Nom. IN Typ. Max. Line Load (Volts) f www.murata-ps.com ...

Page 3

... Baseplate installed, optional special order Remote On/Off Control Polarity: www.murata-ps.com UVQ Series RoHS-6 hazardous substance compliant ( (special quantity order) Blank = Standard pin length L1 = 0.110 (2.79mm 0.145 (3.68mm) * Note: Some model number combinations may not be available. Contact Murata Power Solutions. email: sales@murata-ps.com 22 Feb 2011 MDC_UVQ Models.B18 ) ...

Page 4

... UVQ Series 1.860 (47.2) A 1.030 (26.2) BASEPLATE 0.50 (12.7) 0.188 (4.8) 2.30 (58.4) A 2.00 (50.8) A 0.15 (3.81 0.600 (15.24) Optional pin 9 connects 6 to baseplate. Electrically @ 0.150 (3.81) isolated from converter BOTTOM VIEW email: sales@murata-ps.com 22 Feb 2011 MDC_UVQ Models.B18 1.45 (36.8) 4 EQ. SP. ...

Page 5

... Performance/Functional Specifi cations 24V Models Input Input Current 5 Remote On/Off Control www.murata-ps.com UVQ Series email: sales@murata-ps.com 22 Feb 2011 MDC_UVQ Models.B18 ...

Page 6

... Performance/Functional Specifi cations 24V Models Output Isolation Characteristics www.murata-ps.com UVQ Series email: sales@murata-ps.com 22 Feb 2011 MDC_UVQ Models.B18 ...

Page 7

... Performance/Functional Specifi cations 24V Models Dynamic characteristics Environmental Physical www.murata-ps.com UVQ Series email: sales@murata-ps.com 22 Feb 2011 MDC_UVQ Models.B18 ...

Page 8

... Performance/Functional Specifi cations 48V Models Input Input Current 5 Remote On/Off Control www.murata-ps.com UVQ Series email: sales@murata-ps.com 22 Feb 2011 MDC_UVQ Models.B18 ...

Page 9

... Performance/Functional Specifi cations 48V Models Output Isolation Characteristics www.murata-ps.com UVQ Series email: sales@murata-ps.com 22 Feb 2011 MDC_UVQ Models.B18 ...

Page 10

... Performance/Functional Specifi cations 48V Models Dynamic characteristics Environmental Physical www.murata-ps.com UVQ Series email: sales@murata-ps.com 22 Feb 2011 MDC_UVQ Models.B18 ...

Page 11

... ABSOLUTE MAXIMUM RATINGS ° MECHANICAL SPECIFICATIONS Removal of Soldered UVQ's from Printed Circuit Boards Input Source Impedance I/O Filtering, Input Ripple Current, and Output Noise TO OSCILLOSCOPE + BUS – 33μF, ESR < 700mΩ @ 100kHz 220μF, ESR < 100mΩ @ 100kHz BUS L = 12μH BUS Figure 2 ...

Page 12

... Start-Up Threshold and Undervoltage Shutdown Start-Up Time r On/Off Control R SCOPE C2 LOAD Current Limiting Short Circuit Condition www.murata-ps.com UVQ Series EQUIVALENT CIRCUIT FOR + +Vcc 3 POSITIVE AND NEGATIVE LOGIC MODELS CONTROL REF 1 – COMMON Figure 4. Driving the Remote On/Off Control Pin email: sales@murata-ps.com 22 Feb 2011 MDC_UVQ Models.B18 ...

Page 13

... Wave Solder Operations for through-hole mounted products (THMT) For Sn/Ag/Cu based solders: LOAD R TRIM UP For Sn/Pb based solders: www.murata-ps.com UVQ Series 8 1 +OUTPUT –INPUT 7 +SENSE 2 6 ON/OFF TRIM CONTROL R TRIM DOWN 5 –SENSE 3 4 +INPUT –OUTPUT d email: sales@murata-ps.com 22 Feb 2011 MDC_UVQ Models.B18 LOAD ...

Page 14

... IR drops 8 +OUTPUT –INPUT I OUT 7 +SENSE Sense Current ON/OFF TRIM 6 CONTROL Sense Return 5 –SENSE I Return OUT 4 +INPUT –OUTPUT Contact and PCB resistance losses due to IR drops Figure 8. Remote Sense Circuit Confi guration × ≤ email: sales@murata-ps.com 22 Feb 2011 MDC_UVQ Models.B18 LOAD ...

Page 15

... UVQ Series Aluminum Heatsink Figure 7. Model UVQ Heatsink Assembly Diagram Thermal Performance Power Dissipation [Pd] = Power In – Power Out [1] Power Out / Power In = Effi ciency [ 100 [2] Power Dissipation [Pd] = Power –Effi ciency%/100) [3] Power Dissipation [Pd] = Power Out (Effi ciency%/100 [4] R4 [at airfl ow [natural convection (Airfl LFM) x [Airfl ...

Page 16

... Heat Sink Example 4 4 Heatsink height (see drawing) 0.140 DIA. (3.56) (4 PLACES) MATERIAL: BLACK ANODIZED ALUMINUM 0.10 (2.54) * UVQ SERIES HEATSINKS ARE AVAILABLE IN 3 HEIGHTS: 0.25 (6.35), 0.50 (12.70) AND 1.00 (25.4) www.murata-ps.com UVQ Series 4 4 2.28 (57.91) 1.860 (47.24) 1 ...

Page 17

... Ambient Temperature ( C) UVQ-1.5/40-D24N: Maximum Current Temperature Derating (With baseplate UVQ-2.5/40-D48 Power Dissipation vs. Load Current @ 25° 36V UVQ-3.3/30-D24N: Maximum Current Temperature Derating (With baseplate 400 lfm www.murata-ps.com UVQ Series = 24V, transverse air flow) IN Natural convection 100 lfm 400 lfm Ambient Temperature ( C) ...

Page 18

... UVQ-5/20-D24 Power Dissipation vs. Load Current @ +25° 18V 24V 30V 36V 15.5 17 18.5 20 www.murata-ps.com UVQ Series = 24V, transverse air flow Ambient Temperature ( 18V 24V 30V 36V IN 6.5 8 9.5 11 12.5 14 15.5 Load Current (Amps) email: sales@murata-ps.com 22 Feb 2011 MDC_UVQ Models.B18 18.5 20 ...

Page 19

... Ambient Temperature ( C) UVQ-5/20-D48P: Maximum Current Temperature Derating (No baseplate 36V www.murata-ps.com UVQ Series = 48V, transverse air flow at sea level) IN 100 lfm 200 lfm 300 lfm 400 lfm Natural convection Ambient Temperature ( C) email: sales@murata-ps.com 22 Feb 2011 MDC_UVQ Models.B18 ...

Page 20

... 48V 60V 75V Load Current (Amps) UVQ-12/8-D24P Efficiency vs. Line Voltage and Load Current @ +25° 0.8 UVQ-12/10-D48N: Maximum Current Temperature Derating (With baseplate, V 10.0 9.5 9.0 8.5 8.0 7.5 7.0 6.5 6 UVQ-12/10-D48N Power Dissipation vs. Load Current @ +25° www.murata-ps.com UVQ Series V = 18V ...

Page 21

... UVQ-15/7-D24N Power Dissipation vs. Load Current @ +25° 0.7 4.9 5.6 6.3 7 www.murata-ps.com UVQ Series = 24V, transverse air flow Ambient Temperature ( 36V 30V 24V 18V IN 1.4 2.1 2.8 3.5 4.2 4.9 5.6 Load Current (Amps) email: sales@murata-ps.com 22 Feb 2011 MDC_UVQ Models.B18 6.3 7 ...

Page 22

... UVQ-15/7-D48N Power Dissipation vs. Load Current @ +25° 0.7 4.9 5.6 6.3 7 www.murata-ps.com UVQ Series = 48V, transverse air flow Ambient Temperature ( 75V 60V 48V 36V IN 1.4 2.1 2.8 3.5 4.2 4.9 5.6 Load Current (Amps) email: sales@murata-ps.com 22 Feb 2011 MDC_UVQ Models.B18 6.3 7 ...

Page 23

... Power Dissipation vs. Load Current @ 25° 4.8 5.4 6 0.6 www.murata-ps.com UVQ Series = 24V, transverse air flow) IN 100 lfm 200 lfm 300 lfm 400 lfm Ambient Temperature ( 75V 48V 36V IN 1.2 1.8 2.4 3 3.6 4.2 4.8 Load Current (Amps) email: sales@murata-ps.com 22 Feb 2011 MDC_UVQ Models.B18 5.4 6 ...

Page 24

... V 6.5 6 5.5 5 4.5 500 lfm 4 3 3.45 3.80 4.15 4.50 UVQ-24/4.5-D48N: Maximum Current Temperature Derating (No baseplate, V 4.5 4.3 4.0 3.8 3.5 3.3 3.0 20 3.45 3.80 4.15 4.50 www.murata-ps.com UVQ Series = 48V, transverse air flow) IN 100 lfm 200 lfm 300 lfm ...

Page 25

... UVQ-48/2.5-D48N: Maximum Current Temperature Derating (With baseplate, V 2.6 2.5 2.4 2.3 2.2 2.1 2 2.25 2.5 www.murata-ps.com/locations UVQ Series = 48V, transverse air flow) IN Natural convection 100 lfm 200 lfm Ambient Temperature ( C) © 2011 Murata Power Solutions, Inc. email: sales@murata-ps.com 22 Feb 2011 MDC_UVQ Models.B18 ...

Related keywords