UCQ-3.3/30-D48N-C Murata Power Solutions Inc, UCQ-3.3/30-D48N-C Datasheet
UCQ-3.3/30-D48N-C
Specifications of UCQ-3.3/30-D48N-C
Related parts for UCQ-3.3/30-D48N-C
UCQ-3.3/30-D48N-C Summary of contents
Page 1
... A single-board optimized open-frame design contributes to impressive thermal opera- tion. UCQ’s will operate up to +70°C and 100 LFM airflow with no derating. PWM CONTROLLER INPUT UNDERVOLTAGE, INPUT ...
Page 2
... UCQ-1.5/25-D48N-C 1.5 40 UCQ-1.5/40-D48N-C UCQ-1.8/30-D48N-C 1.8 30 UCQ-2.5/40-D24P-C 2.5 40 100 2.5 30 UCQ-2.5/30-D48N-C 3.3 35 115.5 UCQ-3.3/35-D24P-C UCQ-3.3/20-D48N-C 3.3 20 UCQ-3.3/30-D48N-C 3 100 UCQ-5/20-D24P 100 UCQ-5/20-D48N-C UCQ-5/25-D48N 125 8 12 UCQ-8/12-D24P-C 12 8.3 99.6 UCQ-12/8.3-D48N-C 15 6.7 100.5 UCQ-15/6.7-D24P-C ➀ Please refer to the part number structure for additional ordering part numbers and options. ...
Page 3
... PINS 4, 8: (4.6) 0.060Ø ±0.001 (1.524 ±0.025) I/O Connections Pin Function P32 Pin Function P32 1 −Input 5 2 Remote On/Off 6 3 +Input 7 4 −Output 8 Technical enquiries email: sales@murata-ps.com, tel: MDC_UCQ Models.B06 Page −Sense Output Trim +Sense +Output +1 508 339 3000 ...
Page 4
... Performance Specifications and Ordering Guide ➀ UCQ-1.2/30-D48 UCQ-1.5/25-D48 UCQ-1.5/40-D48 UCQ-1.8/30-D48 UCQ-2.5/40-D24 UCQ-2.5/30-D48 UCQ-3.3/35-D24 Input Input voltage range Start-up threshold, Volts 34 Undervoltage 33 shutdown, V Overvoltage shutdown Reflected (back) ripple current, mA pk-pk Input Current Full load conditions Inrush transient sec Output short circuit load, mA Low line (V = min ...
Page 5
... V range per °C. out No minimum loading. +10% See ordering guide. See ordering guide. See ordering guide. 10,000 10,000 10,000 Technical enquiries email: sales@murata-ps.com, tel: Isolated DC/DC Converters UCQ-12/8.3-D48 35 34 3.04 L-C 10,000 +1 508 339 3000 MDC_UCQ Models.B06 Page ...
Page 6
... Performance Specifications and Ordering Guide ➀ UCQ-1.2/30-D48 UCQ-1.5/25-D48 UCQ-1.5/40-D48 UCQ-1.8/30-D48 UCQ-2.5/40-D24 UCQ-2.5/30-D48 UCQ-3.3/35-D24 Isolation Voltage Input to Output, Volts min. Input to baseplate, Volts min. Baseplate to output, Volts min. Isolation resistance, MΩ Isolation capacitance, pF Isolation safety rating Miscellaneous Current limit inception (98 after 35 out ...
Page 7
... TBD −40 to +85, with derating −40 to +110 −55 to +125 110-125, model dependent To +85°C/85%, non-condensing Technical enquiries email: sales@murata-ps.com, tel: Isolated DC/DC Converters UCQ-12/8.3-D48 10 TBD 14.4 200 µSec to ±1% of final value 50 50 330 ± 508 339 3000 MDC_UCQ Models.B06 Page ...
Page 8
... Performance Specifications and Ordering Guide ➀ UCQ-1.2/30-D48 UCQ-1.5/25-D48 UCQ-1.5/40-D48 UCQ-1.8/30-D48 UCQ-2.5/40-D24 UCQ-2.5/30-D48 UCQ-3.3/35-D24 Physical Outline dimensions Pin material Pin diameter Pin finish Weight, ounces 1.06 Weight, grams 30 Electromagnetic interference Safety Physical Outline dimensions Pin material Pin diameter Pin finish Weight, ounces ...
Page 9
... The UCQ Series implements a soft start circuit to limit the duty cycle of its PWM controller at power up, thereby limiting the input inrush current. ...
Page 10
... See Performance/Functional Specifications. Output Over-Voltage Protection The UCQ output voltage is monitored for an over-voltage condition using a com- parator. The signal is optically coupled to the primary side and if the output volt- age rises to a level which could be damaging to the load, the sensing circuitry will power down the PWM controller causing the output voltage to decrease ...
Page 11
... OUT OUT Trimming Output Voltage UCQ converters have a trim capability (pin 6) that enables users to adjust the output voltage (refer to the trim equations and trim graphs that follow). Adjust- ments to the output voltage can be accomplished via a trim pot (Figure single fixed resistor as shown in Figures 6 and 7. A single fixed resistor can increase or decrease the output voltage depending on its connection. Resistors should be located close to the converter and have TCR’ ...
Page 12
... Applying an external voltage to pin 2 when no input power is applied to the converter can cause permanent damage to the converter. can be added to out www.murata-ps.com Single Output UCQ Models Low-Profile, Quarter Brick, 8.3-40 Amp Isolated DC/DC Converters Typical Performance Curves Technical enquiries email: sales@murata-ps.com, tel: MDC_UCQ Models.B06 Page 508 339 3000 ...
Page 13
... UCQ-1.2/30-D48 Efficiency vs Line Voltage and Load Current @25˚ 48V 75V Load Current (Amps) UCQ-1.5/25-D48 Efficiency vs Line Voltage and Load Current @25˚ 75V 48V 36V Load Current (Amps) UCQ-1.8/30-D48 Efficiency vs Line Voltage and Load Current @25˚ 36V 48V 75V Load Current (Amps) Typical Performance Curves UCQ-1 ...
Page 14
... UCQ-2.5/30-D48 Efficiency vs Line Voltage and Load Current @25˚ 75V 48V 36V Load Current (Amps) UCQ-2.5/40-D24 Efficiency vs Line Voltage and Load Current @25˚ 24V 35V Load Current (Amps) UCQ-3.3/30-D48 Efficiency vs Line Voltage and Load Current @25° 50V 75V Load Current (Amps) Typical Performance Curves UCQ-2 ...
Page 15
... UCQ-3.3/30-D48 Maximum Current Temperature Derating With baseplate 48V (at sea level 100 lfm 15 200 lfm 10 300 lfm 5 400 lfm 0 Ambient Temperature (°C) UCQ-3.3/35-D24 Efficiency vs Line Voltage and Load Current @25˚ 36V 24V 18V Load Current (Amps) UCQ-5/20-D48 Efficiency vs Line Voltage and Load Current @25°C ...
Page 16
... UCQ-12/8.3-D48 Efficiency vs Line Voltage and Load Current @25˚ 75V 48V 36V 0.8 1.6 2.4 3.2 4 Load Current (Amps) Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356 www.murata-ps.com email: sales@murata-ps.com Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights ...