SD-100D-24 Mean Well, SD-100D-24 Datasheet

DC/DC Converters & Regulators 100.8W 24V 4.2A 72-144VDCor85-132VAC

SD-100D-24

Manufacturer Part Number
SD-100D-24
Description
DC/DC Converters & Regulators 100.8W 24V 4.2A 72-144VDCor85-132VAC
Manufacturer
Mean Well
Series
SD-100r
Datasheet

Specifications of SD-100D-24

Product
Isolated
Output Power
100.8 W
Input Voltage Range
72 V to 144 V
Input Voltage (nominal)
96 V
Number Of Outputs
1
Output Voltage (channel 1)
24 V
Output Current (channel 1)
4.2 A
Isolation Voltage
1.5 KV
Package / Case Size
199 mm x 98 mm x 38 mm
Output Type
Single
Output Voltage
24 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SD-100D-24
Manufacturer:
FCI
Quantity:
101
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
(Note 4)
OTHERS
NOTE
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
EFFICIENCY (Typ.)
DC CURRENT (Typ.)
OVERLOAD
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
EMS IMMUNITY
MTBF
DIMENSION
PACKING
100W Single Output DC-DC Converter
Note.3
Note.2
SD-100B-5
5V
20A
0 ~ 20A
100W
100mVp-p
4.5 ~ 5.5VDC
2s, 50ms(only D mode) at full load
20ms(only D mode) at full load
B:19 ~ 36VDC
105 ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.75 ~ 6.75V/10% load
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-10 ~ +60
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
IEC60950-1 CB approved by TUV (for D type only)
I/P-O/P:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to
356.7K hrs min.(SD-100B)
199*98*38mm (L*W*H)
0.65Kg; 20pcs/13.8Kg/0.8CUFT
74%
4.8A/24V
D:18A/96VDC
<0.75mA/120VAC(SD-100D)
2.0%
0.5%
0.5%
0.03%/
(0 ~ 50
(Refer to output load derating curve)
SD-100C-5
75%
2.4A/48V
EN61000-4-2,3,4,6,8; ENV50204, l
C:36 ~ 72VDC
I/P-FG:1.5KVAC
SD-100D-5
76%
1.8A/96V
355.5K hrs min.(SD-100C)
O/P-FG:0.5KVAC
D:72 ~ 144VDC or 85 ~ 132VAC
SD-100B-12
8.5A
12V
0 ~ 8.5A
102W
120mVp-p
11 ~ 16VDC
75%
16.8 ~ 20V/10% load
4.8A/24V
1.0%
0.3%
0.3%
ight
industry level, criteria A
SD-100C-12 SD-100D-12
77%
2.4A/48V
341.9K Hrs min.(SD-100D)
80%
1.8A/96V
S D - 1 0 0
SD-100B-24
4.2A
24V
0 ~ 4.2A
100.8W
150mVp-p
23 ~ 30VDC
31.5 ~ 37.5V/10% load
78%
4.8A/24V
1.0%
0.2%
0.2%
MIL-HDBK-217F (25 )
File Name:SD-100-SPEC 2010-10-18
SD-100C-24 SD-100D-24
81%
2.4A/48V
s e r i e s
83%
1.8A/96V

Related parts for SD-100D-24

SD-100D-24 Summary of contents

Page 1

... EN61000-4-2,3,4,6,8; ENV50204, l 355.5K hrs min.(SD-100C SD-100C-12 SD-100D-12 SD-100B-24 24V 4. 4.2A 100.8W 150mVp 30VDC 1.0% 0.2% 0.2% 77% 80% 78% 2.4A/48V 1.8A/96V 4.8A/24V 31.5 ~ 37.5V/10% load ight industry level, criteria A 341.9K Hrs min.(SD-100D) MIL-HDBK-217F ( SD-100C-24 SD-100D-24 81% 83% 2.4A/48V 1.8A/96V File Name:SD-100-SPEC 2010-10-18 ...

Page 2

... Derating Curve 100 80 SD-100B-5,12,24 SD-100C,D-5, - -10 0 AMBIENT TEMPERATURE ( ) 197 120 199 190 157 RECTIFIERS POWER & SWITCHING FILTER PWM O.L.P. CONTROL Static Characteristics(SD-100D-24V) SD-100C,D- (VERTICAL (HORIZONTAL Case No. 902 Terminal Pin No. Assignment Pin No. Assignment Pin No. 1,2 INPUT 4,5 3 6,7 FG SD-100B,C Pin No. Assignment ...

Related keywords