SCP-50-24 Mean Well, SCP-50-24 Datasheet

Linear & Switching Power Supplies 49.7W 27.6V 1.8A BattCharge/SecDevice

SCP-50-24

Manufacturer Part Number
SCP-50-24
Description
Linear & Switching Power Supplies 49.7W 27.6V 1.8A BattCharge/SecDevice
Manufacturer
Mean Well
Series
SCP-50r
Datasheet

Specifications of SCP-50-24

Product
Switching
Commercial/medical
Commercial
Output Power Rating
49.7 W
Input Voltage
85 VAC to 264 VAC, 120 VDC to 370 VDC
Number Of Outputs
1
Output Voltage (channel 1)
27.6 VDC
Output Current (channel 1)
2.2 A
Mounting Style
Chassis
Output Type
DC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
SPECIFICATION
MODEL
OUTPUT
INPUT
FUNCTION
PROTECTION
ENVIRONMENT
SAFETY &
EMC
(Note 7)
OTHERS
NOTE
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
TEMP. COMPENSATION
OUTPUT VOLTAGE SENSOR
OVERLOAD
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
PEAK 5S
RATED POWER
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
AC CURRENT (Typ.)
EMI CONDUCTION & RADIATION
50W Single Output Switching Power Supply
Note.6
Note.4
Note.5
Note.3
Note.2
4.3A
SCP-50-12
13.8V
3.6A
0 ~ 3.6A
49.7W
120mVp-p
500ms, 30ms/230VAC
50ms/230VAC
85 ~ 264VAC
47 ~ 63Hz
+15,-5%
0.45Kg; 30pcs/14.5Kg/0.95CUFT
4.3 ~ 5.8A rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
16.6 ~ 19.3V
Protection type : Shut down o/p voltage, re-power on to recover
-20 ~ +60
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, CB(IEC60950-1) approved
I/P-O/P:3KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2, 3, 4, 5, 6, 8,11, ENV50204, EN55024, EN61000-6-1, light industry level, criteria A
495.7K hrs min.
129*98*38mm (L*W*H)
81%
1.1A/115VAC
COLD START 45A
<2mA / 240VAC
By NTC (not provide with the power supply)
L=output voltage
2.0%
1.0%
2.0%
0.03%/
(0 ~ 45 )
(Refer to output load derating curve)
+0.7
-0
120 ~ 370VDC
I/P-FG:1.5KVAC
MIL-HDBK-217F (25 )
0.65A/230VAC
16ms/115VAC at full load
V
1200ms, 30ms/115VAC at full load
O/P-FG:0.5KVAC
27.6V
1.8A
0 ~ 1.8A
2.2A
49.7W
200mVp-p
SCP-50-24
+15,-5%
85%
2.2 ~ 2.9A rated output power
33.1 ~ 38.5V
1.0%
1.0%
1.0%
S C P - 5 0
File Name:SCP-50-SPEC 2010-01-27
s e r i e s

Related parts for SCP-50-24

SCP-50-24 Summary of contents

Page 1

... V -0 (Refer to output load derating curve) 0.03 I/P-FG:1.5KVAC O/P-FG:0.5KVAC MIL-HDBK-217F ( SCP-50-24 27.6V 1. 1.8A 2.2A 49.7W 200mVp-p +15,-5% 1.0% 1.0% 1.0% 85% 2.2 ~ 2.9A rated output power 33.1 ~ 38.5V File Name:SCP-50-SPEC 2010-01- ...

Page 2

... FILTER CONTROL O.L.P. Output Derating VS Input Voltage 100 (HORIZONTAL Case No. 903 122.5 129 120 77 RECTIFIERS & FILTER DETECTION CIRCUIT O.V.P. 95 100 115 120 140 160 180 200 220 INPUT VOLTAGE (VAC) 60Hz File Name:SCP-50-SPEC 2010-01- Unit:mm fosc : 60KHz Ta=25 240 264 ...

Page 3

... If the sensor is not used, the charger still works normally. Reference example: Connect 100K Thermistor(THINKING) on NTC. Adjust VR to cause the output voltage is normally voltage. The output voltage will change along with the temperature change 14.4 0.2V SCP-50-12 29.3 0.4V SCP-50-24 V 29.3 27.6 26.4 14.4 13.8 13.2 0 ...

Related keywords