ESS150-24 ETA-USA, ESS150-24 Datasheet
ESS150-24
Specifications of ESS150-24
Related parts for ESS150-24
ESS150-24 Summary of contents
Page 1
... ESS150 SERIES Application Broad needs Input Input Voltage: AC100~240V Input Voltage Range: AC85~264V (DC110~350V) 50/60Hz Input Frequency: 47~440Hz Frequency Range: Single Phase: 14A at 100V; 28A at 200V Inrush Current: *1 ETA USA 16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037 Phone: 1-800-ETA-POWR, (408) 778-2793 Fax: (408) 779-2753 ...
Page 2
... At AC100V 81%-86. 200V 83%-89% 0.89-0.99 OUTPUT HOUSING -MOLEX 0009-50-1063-(5196-06) ESS150-15 ESS150-24 ESS150- 6.5 4.3 13.5~16.5 21.6~26.4 32.4~39.6 150 150 250 30 typ. 30 max 144 120 150 240 150 240 360 180 290 ...
Page 3
... Operate at 105% min of rated current, automatic return Input reentry at shutdown Available Applicable by Option(External signal input is required) Available Not Available (N+1 Operation is Applicable by Diode-OR) Power Source on LED indication; Green 37.5W × 164.5L × 81.5H 600 Visit us at: www.eta-usa.com email at: sales@eta-usa.com 100MΩ(minimum ,30 minute Approved Approved Declared ...
Page 4
... ETA USA 16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037 Phone: 1-800-ETA-POWR, (408) 778-2793 Fax: (408) 779-2753 Derating Curves Visit us at: www.eta-usa.com email at: sales@eta-usa.com ...
Page 5
... Mechanical Drawings ETA USA 16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037 Phone: 1-800-ETA-POWR, (408) 778-2793 Fax: (408) 779-2753 Efficiency Curves Visit us at: www.eta-usa.com email at: sales@eta-usa.com ...
Page 6
... Mechanical Drawing with “–J” connector ETA USA 16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037 Phone: 1-800-ETA-POWR, (408) 778-2793 Fax: (408) 779-2753 Visit us at: www.eta-usa.com email at: sales@eta-usa.com ...