T-40B Mean Well, T-40B Datasheet

Linear & Switching Power Supplies 45W 5V/3A 12V/2A -12V/0.5A

T-40B

Manufacturer Part Number
T-40B
Description
Linear & Switching Power Supplies 45W 5V/3A 12V/2A -12V/0.5A
Manufacturer
Mean Well
Datasheet

Specifications of T-40B

Product
Switching
Commercial/medical
Commercial
Output Power Rating
15 W
Input Voltage
85 VAC to 264 VAC, 120 VDC to 370 VDC
Number Of Outputs
3
Output Voltage (channel 1)
5 V
Output Current (channel 1)
3 A
Output Voltage (channel 2)
12 V
Output Current (channel 2)
2 A
Output Voltage (channel 3)
- 12 V
Output Current (channel 3)
0.5 A
Mounting Style
Chassis
Output Type
DC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
(Note 4)
OTHERS
NOTE
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
OUTPUT NUMBER
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
EMI CONDUCTION & RADIATION
40W Triple Output Switching Power Supply
Note.3
Note.2
T-40A
CH1
5V
3A
0.6 ~ 5A
41.5W
100mVp-p
CH1 : 4.75 ~ 5.5V
800ms, 50ms/230VAC
70ms/230VAC
85 ~ 264VAC
47 ~ 63Hz
305.6K hrs min.
105 ~ 150%/115VAC rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-10 ~ +60
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
CSA 60950-1, (UL60950-1, IEC60950-1, TUV EN60950-1) approved
I/P-O/P:3KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
129*98*38mm (L*W*H)
72%/115VAC
1.2A/115VAC
COLD START 20A/115VAC
<3.5mA / 240VAC
CH1: 5.75 ~ 6.75V
0.44Kg; 30pcs/14.7Kg/0.86CUFT
2.0%
0.5%
0.5%
0.03%/
(0 ~ 50 )on +5V output
(Refer to output load derating curve)
CH2
12V
2A
0.2 ~ 3A
120mVp-p
6.0%
1.0%
4.0%
I/P-FG:1.5KVAC
120 ~ 370VDC
MIL-HDBK-217F (25 )
0.7A/230VAC
16ms/115VAC at full load
1600ms, 50ms/115VAC at full load
CH3
-5V
0.5A
0.1 ~ 1A
100mVp-p
8.0%
1.0%
6.0%
40A/230VAC
O/P-FG:0.5KVAC
T-40B
CH1
45W
CH1 : 4.75 ~ 5.5V
5V
3A
0.6 ~ 5A
100mVp-p
72%/115VAC
2.0%
0.5%
0.5%
CH2
12V
2A
0.2 ~ 3A
120mVp-p
6.0%
1.0%
4.0%
CH3
-12V
0.5A
0.1 ~ 1A
120mVp-p
8.0%
1.0%
6.0%
T-40C
CH1 : 4.75 ~ 5.5V
CH1
45W
5V
3A
0.6 ~ 5A
100mVp-p
72%/115VAC
2.0%
0.5%
0.5%
T- 4 0
File Name:T-40-SPEC 2010-10-18
CH2
15V
1.5A
0.2 ~ 2A
120mVp-p
6.0%
1.0%
4.0%
s e r i e s
CH3
-15V
0.5A
0.1 ~ 1A
120mVp-p
6.0%
1.0%
4.0%

Related parts for T-40B

T-40B Summary of contents

Page 1

... Compliance to EN55022 (CISPR22) Class B (Note 4) HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A MTBF 305.6K hrs min. OTHERS DIMENSION 129*98*38mm (L*W*H) 0.44Kg; 30pcs/14.7Kg/0.86CUFT PACKING NOTE T-40B CH2 CH3 CH1 12V - 0. 45W 120mVp-p ...

Page 2

... Triple Output Switching Power Supply Mechanical Specification 122.5 4 73.5 4.5 129 6.5 120 32 77 Block Diagram EMI I/P FILTER FG Derating Curve 100 - AMBIENT TEMPERATURE ( ) RECTIFIERS POWER & SWITCHING FILTER PWM O.L.P. CONTROL Static Characteristics (B) 13 5.2 12 5.0 11 4.8 10 4 ...

Related keywords