VPL36-700 Triad Magnetics, VPL36-700 Datasheet

Transformers 36V@0.7A 18V@1.4A 25VA

VPL36-700

Manufacturer Part Number
VPL36-700
Description
Transformers 36V@0.7A 18V@1.4A 25VA
Manufacturer
Triad Magnetics
Type
Powerr
Datasheets

Specifications of VPL36-700

Power Rating
25 VA
Primary Voltage Rating
230 V
Secondary Voltage Rating
36 V
Mounting Style
Chassis
Dimensions
82.55 mm L x 79.37 mm W x 49.19 mm H
Product
Power Transformers
Height
49.19 mm
Length
82.55 mm
Width
79.37 mm
Brand/series
World Series™/VPL Series
Configuration
Bobbin
Current, Secondary
1.4/0.7 A
Frequency
50/60 Hz
Length, Lead
8 "
Mounting Hole Centers
2.812 "
Mounting Type
Panel/Chassis
Number Of Outlets
2
Phase
1
Power, Rating
25 VA
Standards
UL
Termination
Leadwires
Voltage, Primary
115/230 VAC
Voltage, Secondary
18/36 VAC
Weight
1.3 lbs.
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
VPL36-700
Electrical Specifications (@25C)
1. Maximum Power: 25.0VA
2. Input Voltage – Series: 230VAC @ 50/60Hz
3. Output Voltage – Series: 36.0V CT@ 0.700A
4. Voltage Regulation: 20% TYP @ full load to no load
Construction:
Dual bobbin construction with an insulated shroud, both made of a high
temperature material that exceeds UL flammability requirements. Shrouds are
provided over the connections of the leads to the windings on both primary and
secondary coils. Devices are designed with a minimum of 6mm creepage distance
between the primary and secondary.
Safety:
These units are designed with 3500VAC isolation between the primary and
secondary, and also, between each winding and the core. Since the dual bobbin
construction effectively reduces capacitance, electrostatic shielding is not required.
International Series Transformers are designed and manufactured to meet most
International Safety agency standards.
Devices are manufactured with a Class B (130º C) insulation system.
Dimensions:
1.937
Weight: 1.3 lbs.
D. Mounting Holes: x 2
Schematic:
Input:
Output: Series – RED to GRY, Jumper YEL to VIO
Primary and secondary windings are designed to be connected in series or parallel. Windings are
not intended to be used independently.
RoHS Compliance:
requirements of 2002/95/EC, known as the RoHS initiative.
A
3.250
Parallel – BLK to WHT, Jumper BLK to BRN and WHT to BLU
Parallel – RED to VIO, Jumper RED to VIO and YEL to GRY
Series – BLK to BLU, Jumper WHT to BRN
B
3.125
C
Parallel: 115VAC@ 50/60Hz
As of manufacturing date February 2005, all standard products meet the
Parallel: 18.0V @ 1.40A
2.812
D
Units: In inches
8.00
E
WHT
BRN
BLU
BLK
.187
F
RED
YEL
GRY
VIO
P
Chassis Mount : International Series
O W E R
T
R A N S F O R M E R
F
A
B
D
C
E

Related parts for VPL36-700

VPL36-700 Summary of contents

Page 1

... VPL36-700 Electrical Specifications (@25C) 1. Maximum Power: 25.0VA 2. Input Voltage – Series: 230VAC @ 50/60Hz Parallel: 115VAC@ 50/60Hz 3. Output Voltage – Series: 36.0V CT@ 0.700A Parallel: 18.0V @ 1.40A 4. Voltage Regulation: 20% TYP @ full load to no load Construction: Dual bobbin construction with an insulated shroud, both made of a high temperature material that exceeds UL flammability requirements ...

Page 2

... VPL24-1100 VPL25-1000 25 25.2 0.990 12.60 25 26.8 0.930 13.40 VPL26-930 VPL28-900 25 28.0 0.890 14.00 25 36.0 0.700 18.00 VPL36-700 VPL10-5000 50 10.0 5.000 5.00 50 12.6 3.970 6.30 VPL12-4000 VPL16-3100 50 16.0 3.125 8.00 VPL20-2500 50 20.0 2.500 10.00 D VPL24-2000 50 24.0 2.083 12 ...

Page 3

Primary and secondary windings are designed ...