291 Staco Energy Products Company, 291 Datasheet - Page 2

Transformers TRANS VAR 0-120V 3A

291

Manufacturer Part Number
291
Description
Transformers TRANS VAR 0-120V 3A
Manufacturer
Staco Energy Products Company
Type
Variable Transformersr
Datasheet

Specifications of 291

Dimensions
2.31 in L x 2.93 in W x 3.28 in H
Product
Variable Transformers
Height
3.28 in
Length
2.31 in
Width
2.93 in
Input Voltage
120V
Output Current
3A
Knob Rotation
CW / CCW
Transformer Mounting
Panel
Secondary Current Nom
3A
No. Of Phases
Single
Primary Voltages
120V
Mounting Type
Panel
Power Rating
0.36kVA
Constant Current Load
3A
Rohs Compliant
Yes
Current Rating
3A
Leaded Process Compatible
No
Output Voltage
120V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
291-H36AB
Manufacturer:
WAK
Quantity:
4 909
Part Number:
291000256811+
Quantity:
22
Part Number:
29102C
Manufacturer:
MURATA/村田
Quantity:
20 000
Part Number:
29103C
Manufacturer:
MURATA/村田
Quantity:
20 000
Part Number:
29104
Manufacturer:
ST
0
Part Number:
29104C
Manufacturer:
MURATA/村田
Quantity:
20 000
Part Number:
29105C
Manufacturer:
MURATA/村田
Quantity:
20 000
Part Number:
2911-0033
Manufacturer:
MOLEX
Quantity:
930
Part Number:
2911-0042
Manufacturer:
N/A
Quantity:
42 425
Part Number:
2911-0042
Manufacturer:
SMD
Quantity:
35 000
Company:
Part Number:
2911-05-321
Quantity:
129
100/200 Series
These manually operated panel mounted units are available in
single and three phase models from 0.8 to 3.0 amperes. The
171, 201, 221-B and 291 units operate from 120 volt input,
while the 252 unit operates from a 240 volt input. STACO’s coil
tapping arrangement permits an output voltage from 0 to line
3PN221B
PART NO.
221-B-2
221-B-3
221-B
171-2
171-3
201-2
201-3
252-2
252-3
171
201
252
WIRING
Delta π
Delta π
Delta π
Delta π
Single
Phase
Single
Phase
Series
Phase
Phase
Wye π
Single
Phase
Single
Phase
Series
Phase
Phase
Wye π
Single
Phase
Single
Phase
Series
Phase
Phase
Wye π
Single
Phase
Single
Phase
Single
Phase
Series
Phase
Phase
Wye π
Three
Three
Three
Three
Three
Three
Three
Three
Open
Open
Open
Open
VOLTS
120++
240++
120++
240++
120++
240++
240++
480++
120
240
120
240
120
240
120
240
480
INPUT
HERTZ
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
VOLTS
0-120
0-132
0-240
0-264
0-120
0-132
0-240
0-120
0-132
0-240
0-264
0-120
0-132
0-240
0-120
0-132
0-240
0-264
0-120
0-132
0-240
0-132
0-240
0-264
0-480
0-528
0-240
0-264
0-480
0-528
AMPS
MAX
1.75
1.75
1.75
1.75
1.75
1.75
1.75
2.50
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.5
2.5
2.5
2.5
2.5
2.5
2.5
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
CONSTANT
CURRENT
LOAD
OUTPUT
MAX
KVA
0.21
0.23
0.42
0.46
0.36
0.40
0.73
0.24
0.26
0.48
0.53
0.42
0.46
0.83
0.30
0.33
0.60
0.66
0.52
0.57
1.04
0.33
0.19
0.21
0.38
0.42
0.33
0.37
0.67
0.73
AMPS
MAX
2.2
2.2
2.2
2.2
2.5
2.5
2.5
2.5
3.2
3.2
3.2
3.2
1.0
1.0
1.0
1.0
IMPEDANCE
CONSTANT
voltage in either the clockwise or counterclockwise direction
and from 0 to 10% above line voltage in the clockwise direc-
tion. Two and three ganged, manually operated units are avail-
able for increased single phase voltage ratings and for three
phase applications.
LOAD
MAX
0.26
0.53
0.46
0.92
0.30
0.60
0.52
1.04
0.38
0.77
0.67
1.33
0.24
0.48
0.42
0.83
KVA
INCREASE
ROTATION
VOLTAGE
SHAFT
CCW
CCW
CCW
CCW
CCW
CCW
CCW
CCW
CCW
CCW
CCW
CCW
CCW
CCW
CCW
CCW
FOR
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
LINE CORD & RECEPTACLE
2-1-2
1-2-1
4-1-4
2-2-2
1-1-1
2-1-2
1-2-1
4-1-4
2-2-2
1-1-1
2-1-2
1-2-1
4-1-4
2-2-2
1-1-1
2-1-2
1-2-1
4-1-4
2-2-2
1-1-1
4-4-4
TERMINAL CONNECTIONS
Input
1-2
1-2
1-4
2-2
1-1
4-4
1-2
1-2
1-4
2-2
1-1
4-4
1-2
1-2
1-4
2-2
1-1
4-4
1-2
1-2
1-4
2-2
1-1
4-4
As Viewed from Base End
(For increasing Voltage)
Jumper• Output
1-1-1
2-2-2
1-1-1
2-2-2
1-1-1
2-2-2
1-1-1
2-2-2
1-1-1
1-1
2-2
1-1
1-1
2-2
1-1
1-1
2-2
1-1
1-1
2-2
1-1
1-1
2-2
1-1
1-1
2-2
1-1
1-1
2-2
1-1
1-1
2-2
1-1
3-1-3
3-2-3
3-1-3
3-3-3
3-3-3
3-1-3
3-2-3
3-1-3
3-3-3
3-3-3
3-1-3
3-2-3
3-1-3
3-3-3
3-3-3
3-1-3
3-2-3
3-1-3
3-3-3
3-3-3
3-3-3
1-3
2-3
1-3
3-3
3-3
3-3
1-3
2-3
1-3
3-3
3-3
3-3
1-3
2-3
1-3
3-3
3-3
3-3
1-3
2-3
1-3
3-3
3-3
3-3
(Pg 8 & 9)
SCHE-
MATIC
1 & 5
1 & 6
1 & 4
1 & 5
1 & 6
1 & 4
1 & 5
1 & 6
1 & 4
1 & 5
1 & 6
1&4
1
1
1
3
1
LBS.
4 1/4
4 1/4
6 1/2
4 1/4
4 1/4
6 1/2
2 1/2
5 1/2
5 1/2
8 1/4
2 1/2
5 1/2
5 1/2
8 1/4
NET
WT.
2
2
3

Related parts for 291