ACDC-100 Amprobe, ACDC-100 Datasheet - Page 3

Clamp Multimeters & Accessories AC/DC CLAMP-ON

ACDC-100

Manufacturer Part Number
ACDC-100
Description
Clamp Multimeters & Accessories AC/DC CLAMP-ON
Manufacturer
Amprobe
Datasheet

Specifications of ACDC-100

Accuracy
+/- 1.5 %
Frequency
40 Hz to 100 Hz
Maximum Ac Current
1000 A
True Rms
No
Voltage
600 V
Ranging
Auto, Manual
Display Count
4000
Features
Carrying case, test leads, batteries and user manual included
Dmm Type
Clamp
Voltage Measuring Range Dc
400mV To 600V
Voltage Measuring Range Ac
400mV To 600V
Current Measuring Range Dc
0A To 1000A
Current Measuring Range Ac
400A To 800A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
na, Lead free / RoHS Compliant
Other names
2740452
1000A ACDC-100 AC/DC Clamp-On Multimeter
General Specifications
Function
AC Current (Clamp-on)
1)
2)
Display:
Update Rate:
Polarity:
Low Battery:
Operating Temperature:
Relative Humidity:
Altitude:
Storage Temperature:
Temperature Coefficient:
Sensing:
Safety:
Transient protection:
Pollution degree:
E.M.C.:
Overload Protections:
Power Supply:
Power Consumption:
APO Timing:
APO Consumption:
Dimension:
Weight:
Jaw opening & Conductor diameter:
Induced error from adjacent current-carrying conductor: < 0.01A/A
Accuracy is specified at <50A in this frequency bandwidth due to limited calibrator output capability for testing
In an RF field of 3V/m:
Clamp-on jaws: DC 1000A or AC 800A rms continuous + & COM terminals (all functions) : 600VDC/VAC rms
400.0A
800A
Capacitance function is not specified Other function ranges: Total Accuracy = Specified Accuracy + 45 digits
Performance above 3V/m is not specified
15Hz ~ 40Hz
40Hz ~ 200Hz
200Hz ~ 400Hz @ <50A
400Hz ~ 1kHz @ <50A
15Hz ~ 40Hz @ 400A ~ 600A
40Hz ~ 100Hz @ 400A ~ 600A
15Hz ~ 60Hz @ 600A ~ 800A
3-3/4 digits 4000 counts LCD display
3 per second nominal
Automatic
Below approx. 2.4V
0℃ to 40℃
Maximum relative humidity 80% for temperature up to 31℃ decreasing linearly to 50% relative
humidity at 40℃
Operating below 2000m
-20℃ to 60℃, < 80% R.H. (with battery removed)
nominal 0.15 x (specified accuracy)/ ℃ @(0℃ -18℃ or 28℃ -40℃), or otherwise specified
Average sensing
Meets EN61010-1:2001; IEC61010-2-032(2002), EN61010-2-032(2002), UL61010B-2-032(2003)
Category III 600 Volts AC & DC.
6.5kV (1.2/50μs surge) for all models
2
Meets EN61326-1
standard 1.5V AAA Size (NEDA 24G or IEC R03) battery X 2; or 1.5V
AAA Size (NEDA 24A or IEC LR03) alkaline battery X 2
typical 11mA for ACA/DCA and 2.9mA for other functions
Idle for 30 minutes
typical 10μA
L227mm X W78mm X H40mm
290 gm approx
50mm max
Range
2)
2)
2.0% + 5d
1.5% + 5d
1.5% + 5d
2.0% + 5d
2.0% + 5d
1.5% + 4d
5.0% + 30d
Accuracy
1)
1)
1)
1)
1)
1)
1)
www.Amprobe.com
Data Sheet