AC68C Amprobe, AC68C Datasheet - Page 2

Clamp Multimeters & Accessories AC/DC CLAMP-ON DMM TRMS 600A

AC68C

Manufacturer Part Number
AC68C
Description
Clamp Multimeters & Accessories AC/DC CLAMP-ON DMM TRMS 600A
Manufacturer
Amprobe
Type
Current Clampr
Datasheet

Specifications of AC68C

Frequency
4 KHz, 20 KHz
Maximum Ac Current
400 A, 600 A
True Rms
No
Voltage
600 V
Ranging
Auto
Display Count
4000
Features
Carrying case included
Dmm Type
Clamp
Voltage Measuring Range Dc
600V
Voltage Measuring Range Ac
400V / 600V
Current Measuring Range Dc
400A / 600A
Current Measuring Range Ac
400A / 600A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
na, Lead free / RoHS Compliant
Other names
2727919
AC68C Clamp Type Digital Multimeter
Specifications
DC Voltage
AC Voltage (40-450 Hz)
DC Current
AC Current (40-450 Hz)
Frequency (Hz), Current and Voltage
Resistance
Diode Test
Continuity
Peak Hold Measurement AC Voltage (40-450 Hz)
Peak Hold Measurement AC Current (40-450 Hz)
Overload Protection
Amprobe® Test Tools
website: www.Amprobe.com
email: info@amprobe.com
Everett, WA 98203
Tel: 877-AMPROBE
Amprobe® Test Tools
Function
Ranges
Resolution
Input Impedance
Range
Resolution
Input Impedance
Ranges
Resolution
Ranges
Resolution
Ranges
Resolution
Sensitivity
Range
Resolution
Open Circuit Volts
Max Short Circuit Current
Resolution
Open Circuit Volts
Max Short Circuit Current
Range Threshold
Open Circuit Volts
Max Short Circuit Current
Range
Resolution
Input Impedance
Range
Resolution
Voltage
Current
Resistance
Diode
(23°C ± 5 °C; < 80 % R.H. non-condensing)
Amprobe® Test Tools Europe
In den Engematten 14
79286 Glottertal, Germany
Tel.: +49 (0) 7684 8009 - 0
Range
600 V
1 V in 600 V range
10 MW
400 V, 600 V
0.1 V in 400 V range
10 MW
400 A, 600 A
0.1 A in 400 A range
400 A, 600 A
0.1 A in 400 A range
4 kHz, 20 kHz
1 Hz in 4 kHz range
5 A/1 V in 4 kHz range
5 A/5 V in 20 kHz range
4 kW
1 W in 4 kW range
0.5 V DC
0.8 mA
0.001 V
3.2 V DC
0.8 mA
Tone at 40 W ± 15 W
3.2 V DC
0.8 mA
400 V, 600 V
0.1 V in 400 V range
10 MW
400 A, 600 A
0.1 A in 400 A range
1000 V DC/750 V AC
800 Amps
660 V RMS
660 V RMS
Accuracy
± (0.75 % rdg + 2 dgts)
± (1.2 % rdg + 5 dgts)
± (2 % rdg + 5 dgts)
± (2 % rdg + 5 dgts)
± (0.5 % rdg + 5 dgts)
± ( 1.0 % rdg + 5 dgts)
± (1.5 % rdg + 10 dgts)
± (2.0 % rdg + 10 dgts)
± (1.0 % rdg + 2 dgts)
©2007 Amprobe Test Tools. All rights reserved.
9/2007 1646618 D-US-N Rev C
www.Amprobe.com