33XR-A Amprobe, 33XR-A Datasheet - Page 2

Digital Multimeters PROF DMM W/TEMP AND CAPACITANCE

33XR-A

Manufacturer Part Number
33XR-A
Description
Digital Multimeters PROF DMM W/TEMP AND CAPACITANCE
Manufacturer
Amprobe
Datasheet

Specifications of 33XR-A

Accuracy
+/- 0.7 %
True Rms
No
Min / Max Hold
Yes
Peak Hold
Yes
Data Hold
Yes
Resistance Range
400 Ohms to 4 M Ohms
Capacitance Range
4 uF to 4000 uF
Frequency
40 MHz
Equipment Type
Digital Multimeter with Temperature and Capacitance
Display Count
3999
Ranging
Manual
Dmm Type
Hand Held
Voltage Measuring Range Dc
400mV To 1000V
Voltage Measuring Range Ac
400mV To 750V
Current Measuring Range Dc
400µA To 10A
Current Measuring Range Ac
400µA To 10A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
na, Lead free / RoHS Compliant
Other names
2727788
33XR-A Digital Multimeter
General Specifications
Specifications
DC Voltage
AC Voltage (45 Hz to 500 Hz)
DC Current
AC Current (45 Hz to 500 Hz)
Resistance
Amprobe® Test Tools
Manual Ranging
Display:
Display Update Rate:
Power Battery:
Battery Life:
Operating Temperature:
Storage Temperature:
Dimensions:
Weight:
Function
Ranges
Resolution
Input Impedance
Ranges
Accuracy
Resolution
Input Impedance
Ranges
Accuracy
Resolution
Voltage Burden
Ranges
Accuracy
Resolution
Voltage Burden
Ranges
Accuracy
Resolution
Open Circuit Voltage
(23 °C ± 5 °C, <75 % R.H. non-condensing)
3-3/4 digit LCD, 3999 counts with 41-segment analog bar graph
2/sec, nominal
9 V NEDA 1604, JIS 006P, IEC 6F22
300 hrs typical (alkaline)
0 °C to 45 °C at < 70 % R.H.
-20 °C to 60 °C, 0 to 80 % R.H. with battery removed from meter
196 x 92 x 60 mm (7.7” x 3.5” x 2.3” )
400 gr (0.9 lb) without holster, including battery
Range
400 mV, 4 V, 40 V, 400 V, 1000 V
100 μV
10 MW
400 mV, 4 V, 40 V, 400 V, 750 V
4 V Range: 200 Hz to 500 Hz
All other ranges
100 μV
10 MW
400 μA to 300 mA ranges
10 A range
0.1 μA
400 μA range: 1 mV/μA
4 mA range: 100 mV/1 mA
40 mA range: 12 mV/1 mA
300 mA range: 4 mV/1 mA
10 A range: 100 mV/1 A
400 μA, 4 mA, 40 mA, 300 mA, 10 A
400 μA to 300 mA ranges
10 A range
0.1 μA
See DC Current
400 W and 40 kW ranges
4 MW range
100 mW
400 W range: 3.0 V DC
All other ranges: 0.5 V DC typical
400 μA, 4 mA, 40 mA, 300 mA, 10 A
400 W, 40 kW, 4 MW
Accuracy
± (0.7 % rdg + 1 dgt)
± (2.0 % rdg + 4 dgts)
± (1.5 % rdg + 4 dgts)
± (1.0 % rdg + 1 dgt)
± (2.0 % rdg + 3 dgts)
± (1.5 % rdg + 4 dgts)
± (2.5 % rdg + 4 dgts)
± (1.0 % rdg + 4 dgts)
± (1.2 % rdg + 4 dgts)
www.Amprobe.com