35XP-A Amprobe, 35XP-A Datasheet - Page 3

Digital Multimeters COMPACT DMM W/TEMP FREQ AND CAPACITANCE

35XP-A

Manufacturer Part Number
35XP-A
Description
Digital Multimeters COMPACT DMM W/TEMP FREQ AND CAPACITANCE
Manufacturer
Amprobe
Datasheet

Specifications of 35XP-A

Accuracy
+/- 0.5 %
True Rms
No
Min / Max Hold
No
Peak Hold
No
Data Hold
Yes
Resistance Range
400 Ohms to 40 M Ohms
Capacitance Range
4 nF to 4 mF
Frequency
4 KHz to 1 MHz
Equipment Type
Digital Multimeter
Display Count
3999
Dmm Type
Handheld
Voltage Measuring Range Dc
400mV To 1000V
Voltage Measuring Range Ac
400mV To 750V
Current Measuring Range Dc
400µA To 2A
Current Measuring Range Ac
400µA To 400mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
na, Lead free / RoHS Compliant
Other names
2727849
35XP-A Digital Multimeter
Specifications, cont.
Capacitance
Temperature
Frequency
Continuity
Diode Test
Non-Contact Voltage Indicator
Sense voltage 70 V to 600 V AC beeper chirps and big bright red LED comes on, works on all ranges
Function
Resolution
Test Voltage
Test Frequency
Input Protection
Resolution
Overload Protection
Resolution
Sensitivity
Minimum Pulse Width
Duty Cycle Limits
Overload Protection
Audible Indication
Response Time
Overload Protection
Test Current
Resolution
Open Circuit Voltage
Overload Protection
Range
4 nF, 40 nF, 400 nF, 4 μF
40 uF, 400 uF
4 mF
1 pF
< 1 V
1.3 Hz on 4 nF to 40 μF ranges, 0.7 Hz on 400 μF, 4 mF ranges
2 A/1000 V fast blow ceramic fuse 6.3 mm x 32 mm on A input
400 °C, 1000 °C, 400 °F, 1832 °F
-20 °C to 10 °C
10 °C to 200 °C
200 °C to 1000 °C
-4 °F to 50 °F
50 °F to 400 °F
400 °F to 1832 °F
0.1 °C, 0.1 °F
1000 V DC or 750 V AC RMS
1000 V 600 V 300 V
4 k, 40 k, 400 k, 1 M
1 Hz
10 Hz to 1 MHz: >2.5 V rms
> 25 ns
> 30 % and < 70 %
1000 V DC or 750 V AC RMS
Less than 25 W
100 ms
1000 VDC or 750 VAC rms
1.2 mA (approximate)
1 mV
3.0 DC typical
1000 V DC or 750 V AC RMS
± (5.0 % rdg + 30 dgts)
± (5.0 % rdg + 5 dgts)
± (5.0 % rdg + 15 dgts)
± (2.0 % rdg + 4 °C)
± (1.0 % rdg + 3 °C)
± (3.0 % rdg + 2 °C)
± (2.0 % rdg + 8 °F)
± (1.0 % rdg + 6 °F)
± (3.0 % rdg + 4 °F)
± (0.1 % rdg + 3 dgts)
± (1.5 % rdg + 3 dgts)
www.Amprobe.com
Accuracy
Data Sheet