Digital Multimeters PROF DMM TRUE RMS W/ OPTICAL PC INTERFACE

38XR-A

Manufacturer Part Number
38XR-A
Description
Digital Multimeters PROF DMM TRUE RMS W/ OPTICAL PC INTERFACE
Manufacturer
Amprobe
Datasheet

Specifications of 38XR-A

Accuracy
+/- 0.25 %
True Rms
Yes
Min / Max Hold
Yes
Peak Hold
Yes
Data Hold
Yes
Resistance Range
1 K Ohms to 40 M Ohms
Capacitance Range
40 nF to 400 uF
Frequency
100 Hz to 10 MHz
Equipment Type
Digital Multimeter with Optical PC Interface
Display Count
10000
Ranging
Auto
Dmm Type
Hand Held
Voltage Measuring Range Dc
1000mV To 1000V
Voltage Measuring Range Ac
1000mV To 750V
Current Measuring Range Dc
100µA To 10A
Current Measuring Range Ac
100µA To 10A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
na, Lead free / RoHS Compliant
Other names
2727824
38XR-A Digital Multimeter
General Specifications
Specifications
DC Voltage
AC Voltage (45 Hz to 2 kHz) True RMS
AC coupled True RMS specified from 5% to 100 % of range
AC + DC Voltage (45 Hz to 2 kHz)
DC coupled True RMS specified from 5 % to 100 % of range
DC Current
AC Current (True RMS) ( AC + DC) (45 Hz – 1kHz)
AC coupled True RMS specified from 5 % to 100 % of range
AC + DC Accuracy
AC + DC: AC coupled True RMS specified from 10 % to 100 % of range
Resistance
Amprobe® Test Tools
Autoranging
Display:
Display Update Rate:
Power Battery:
Battery Life:
Storage Temperature:
Temperature Coefficient:
Altitude:
Dimensions:
Weight:
Function
Ranges
Resolution
Ranges
Accuracy
Ranges
Accuracy
Resolution
Ranges
Resolution
Ranges
Accuracy
Resolution
Ranges
Accuracy
Resolution
(23 °C ± 5 °C, <75 % R.H. non-condensing)
4-3/4 digit LCD, 10,000 counts with 41-segment analog bar graph
2/sec, nominal
9 V NEDA 1604, JIS 006P, IEC 6F22
150 hrs typical (alkaline) frequent use of backlight will decrease battery life; Operating Temperature: 0
°C to 45 °C at < 70% R.H.
-20 °C to 60 °C, 0 to 80 % R.H. with battery removed from meter
0.1 x (specified accuracy) per °C (0 °C to 18 °C , 28 °C to 45 °C)
2000 m (6562 ft)
196mm x 96mm x 60 mm (7.8” x 3.55” x 2.4”)
400 gr (1 lb) without holster, including battery
Range
1000 mV, 10 V, 100 V, 1000 V
100 μV
1000 mV, 10 V, 100 V, 750 V
750 V range:
All other ranges, 45 to 500 Hz:
All other ranges, 500 to 2 kHz:
1000 mV, 10 V, 100 V, 750 V
750 V range: 45 to 1 kHz:
All other ranges, 45 to 500 Hz:
All other ranges, 500 to 2 kHz:
100 μV
100 μA, 1000 uA, 10 mA, 100 mA, 400 mA, 10 A
Accuracy 100 μA range:
1000 uA to 400 mA ranges:
10 A range:
0.01 μA
100 μA, 1000 μA, 10 mA, 100 mA, 400 mA, 10 A
100 μA to 100 mA ranges:
400 mA range:
10 A range:
0.01 μA
100 μA to 400 mA ranges:
10 A range:
1000 W, 10 kW, 100 kW, 1000 kW, 10 MW, 40 MW
1000 W to 1000 kW ranges:
10 MW range:
40 MW range:
100 mW
± (0.25 % rdg + 5 dgt)
45 to 1 kHz: ± (2.0 % rdg + 10 dgts)
± (1.2 % rdg + 10 dgts)
± (2.0 % rdg + 10 dgts)
± (2.5 % rdg + 10 dgts)
± (1.5 % rdg + 10 dgts)
± (2.5 % rdg + 10 dgts)
± (0.5 % rdg + 10 dgt)
± (0.5 % rdg + 5 dgts)
±(1.5 % rdg + 10 dgt)
± (1.5 % rdg + 20 dgts)
± (2.0 % rdg + 10 dgts)
± (2.5 % rdg + 20 dgts)
± (2.0 % rdg + 20 dgts)
± (3.0 % rdg + 20 dgts)
± (0.5 % rdg + 8 dgts)
± (1.0 % rdg + 10 dgts)
± (2.0 % rdg + 10 dgts)
Accuracy
www.Amprobe.com
Data Sheet