37XR-A Amprobe, 37XR-A Datasheet - Page 2

Digital Multimeters PROF DMM TRUE RMS W/COMP LOGIC TEST

37XR-A

Manufacturer Part Number
37XR-A
Description
Digital Multimeters PROF DMM TRUE RMS W/COMP LOGIC TEST
Manufacturer
Amprobe
Datasheet

Specifications of 37XR-A

Accuracy
+/- 0.1 %
True Rms
Yes
Min / Max Hold
No
Peak Hold
Yes
Data Hold
Yes
Resistance Range
1 K Ohms to 40 M Ohms
Capacitance Range
40 nF to 400 uF
Frequency
10 Hz to 40 MHz
Equipment Type
Digital Multimeter
Display Count
10000
Ranging
Auto
Dmm Type
Hand Held
Voltage Measuring Range Dc
1000mV To 1000V
Voltage Measuring Range Ac
1000mV To 750V
Current Measuring Range Dc
100µA To 10A
Current Measuring Range Ac
100µA To 10A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
na, Lead free / RoHS Compliant
Other names
2727808
37XR-A Digital Multimeter
General Specifications
Specifications
Amprobe® Test Tools
Autoranging;
Display:
Display Update Rate:
Battery Life:
Operating Temperature:
Storage Temperature:
Temperature Coefficient:
Altitude:
Dimensions:
Weight:
Function
DC Voltage
AC Voltage (45 Hz to 2 kHz) True RMS
DC Current
AC Current (45 Hz to 1 kHz) True RMS
Resistance
Capacitance
Ranges
Resolution
Ranges
Resolution
AC coupled True RMS specified from 5 % to 100 % of range
Ranges
Resolution
Ranges
Resolution
AC coupled True RMS specified from 5 % to 100 % of range
Ranges
Ranges
Resolution
(23 °C ± 5 °C, <75 % R.H. non-condensing)
4-3/4 digit LCD, 10,000 counts with 41-segment analog bar graph
2/sec, nominal; Power Battery: 9 V NEDA 1604, JIS 006P, IEC 6F22
150 hrs typical (alkaline) frequent use of backlight will decrease battery life
0 °C to 45 °C at < 70 % R.H.
-20 °C to 60 °C, 0 to 80 % R.H. with battery removed from meter;
0.1 x (specified accuracy) per °C ( 0 °C to 18 °C , 28 °C to 45 °C)
2000 m (6562 ft)
195 x 92 x 60 mm (7.75” x 3.55” x 2.4”)
400 gr (1 lb) without holster, including battery
1000 mV, 10 V, 100 V, 1000 V
100 μV
1000 mV, 10 V, 100 V, 750 V
750 V range: 45 to 1 kHz:
All other ranges, 45 to 500 Hz:
All other ranges, 500 to 2 kHz:
100 μV
100 μA, 1000 μA, 10 mA, 100 mA, 400 mA, 10 A
100 μA range:
1000 uA to 400 mA ranges:
10 A range:
0.01 μA
100 μA, 1000 μA, 10 mA, 100 mA, 400 mA, 10 A
100 μA to 100 mA ranges:
400 mA range:
10 A range:
0.01 μA
1000 W, 10 kW, 100 kW, 1000 kW, 10 MW, 40 MW
1000 W to 1000 kW ranges:
10 MW range:
40 MW range:
40 nF, 400 nF, 4 μF, 40 μF, 400 μF
40 nF, 400 μF ranges:
400 nF to 40 μF ranges:
0.01 nF
Range
± (0.1 % rdg + 5 dgt)
± (2.0 % rdg + 10 dgts)
± (1.2 % rdg + 10 dgts)
± (2.0 % rdg + 10 dgts)
± (0.5 % rdg + 10 dgt)
± (0.5 % rdg + 5 dgts)
± (1.5 % rdg + 10 dgt)
± (1.5 % rdg + 10 dgts)
± (2.0 % rdg + 10 dgts)
± (2.5 % rdg + 10 dgts)
± (0.5 % rdg + 8 dgts)
± (1.0 % rdg + 10 dgts)
± (2.0 % rdg + 10 dgts)
± (3.0 % rdg + 10 dgts)
± (3.0 % rdg + 5 dgts)
Accuracy
www.Amprobe.com
Data Sheet