08890 Simpson, 08890 Datasheet

no-image

08890

Manufacturer Part Number
08890
Description
Analog Panel Meters 125 0-10 DCV 2.5'
Manufacturer
Simpson
Type
Voltager
Datasheet

Specifications of 08890

Equipment Type
DC Voltage Meter
Range
0 - 10
Size
2.50 in
Accuracy
± 2% F.S.
Application
For industrial or commercial
Connection Type
Stud
Dimensions
1.39"H×2.18"Dia. in.
Display Type
Analog
Function
Voltage
Impedance
1000 Ohms⁄V
Length, Scale
1.8 in.
Material, Casing
Plastic
Movement
Annular, Self-Shielding
Primary Type
Electromechanical
Range, Measurement
0 to 10 VDC
Repeatability
2%
Resistance
± 15%
Response Time
1.5 Sec. (Max.)
Standards
UL Recognized
Temperature, Operating
-20 to +65 °C
Voltage, Range
0 to 10 V
Weight
7 Oz.
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Specifications
Accuracy:
Frequency models:
Wattmeters:
Movement:
Tracking:
Shielding:
Response Time:
Overload (1 sec.):
Overload
(Continuous):
Repeatability:
Dial:
Case:
Resistance:
Operating Temp:
Pointer:
Scale Length:
Net Weight:
• Glass window for optimum viewing
• Rugged black plastic case
• Black spade-type pointer for easy distant
reading
±2% F.S. (Iron-Vane), ±3% F.S. (Rectifier)
45-55Hz ±0.3Hz (120V-240V)
55-65Hz ±0.3Hz (120V-240V)
380-420Hz ±1.2Hz (120V-240V)
+2% F.S.; Compensated Meters: +3% F.S.
Models 55, 155: Iron-vane, magnetically damped
Models 45, 145: Annular, rectifier type
Models 85 & 185: small core magnet, self-shielding
Models 25, 27, 29, 125: Annular, self-shielding
±3%
Calibration is unaffected by magnetic panel mounting.
1.5 seconds maximum
10 times F. S.
1.5 times F. S.
2%
Sharp clear scale. Each dial arc is calibrated to track
the specific type of movement used.
High density black plastic
±15%
-4°F to +149°F (-20°C to +65°C)
Models 85 & 185: knife edge, black finish
All others: spade pointer with black matte finish
Model 155 & 185: 1.6” (40.6mm)
Models 125 & 145: 1.8” (45.7mm)
Model 55: 2.3” (58.4mm)
Models 25, 27, 45 & 85: 2.5” (63.5m)
Model 29: 3.80” (96.5mm)
Models 55, 155 & 185: 5oz (0.14kg)
Models 85, 125, 145 & 45: 7oz (0.20kg)
Models 25 & 27: 8oz (.23kg)
Model 29: 11oz. (.31kg)
* Rectified Models
AC Milliammeters,
0-100
<> Available on special order.
* These meters require use of an external current transformer from page C4-C6
Range
AC Microammeters Rectifier Type,
Ordering Information
Range
Range
0-1
0-5
0-10
0-15
0-100
0-150
0-250
0-500
AC Ammeters,
4-2 2 0mA Process Meters,
0-1
0-1.5
0-2
0-3
0-5
0-10
0-15
0-25
0-30
0-50
0-75
0-75
0-100
0-150
0-200
0-250
0-300
0-500
Range
4-20
(ohms) @ 60 Hz
Impedance
Impedance
Approx.
(ohms)
Approx. Impedance
Approx.
3400
(ohms) @ 60 Hz
887.0
717.2
80.0
8.76
600
200
3.1
.9
Impedance
Approx.
Iron Vane Movement
(Ohms)
.0025
.0015
.0002
.213
.105
.065
.028
.008
.004
.002
.001
.008
.008
.008
.008
.008
.008
.008
5.0
Iron Vane & Rectified Movement
Model 155
06080
2-1/2"
Dial indicates 0-100 Percent
<>
<>
<>
<>
<>
<>
<>
Model/Size and Catalog Number
Model/Size and Catalog Number
Model/Size and Catalog Number
Model 155
02200*
02210*
02220*
02240*
02260*
Model/Size and Catalog number
02100
02120
02130
02140
02150
02160
02170
02180
02190
2-1/2"
<>
<>
<>
<>
3-1/2” Model 45
Self Shielding Movement
Model 55
04080
3-1/2” Model 25
05380
05400
05410
35069
05420
05430
3-1/2"
<>
<>
35022
Model 55
01060*
01070*
01080*
01090*
01100*
01110*
00950
00960
00970
00980
00990
01001
01010
01020
01030
01040
03432
3-1/2"
<>
Model 45
more >>
06820*
06840*
4-1/2”
<>
<>
<>
<>
<>
<>

08890 Summary of contents

Page 1

Glass window for optimum viewing • Rugged black plastic case • Black spade-type pointer for easy distant reading Specifications Accuracy: ±2% F.S. (Iron-Vane), ±3% F.S. (Rectifier) 45-55Hz ±0.3Hz (120V-240V) Frequency models: 55-65Hz ±0.3Hz (120V-240V) 380-420Hz ±1.2Hz (120V-240V) +2% F.S.; ...

Page 2

... Model 125 (ohms 10.0 06970 20.0 <> Self Shielding Movement Approx. Model/Size and Catalog Number Impedance 2-1/2” (Ohms Model 125 08850 <> 08870 08890 1000 08900 Ohms 08910 Per 08920 Volt 08930 08940 08950 08960 08970 <> <> 2000 <> ...

Page 3

Panel Meter Cut-out Dimensions NOTE: “T” model suffix used for Taut-Band movement 2-1/2"-Models 125, 125T, 145, 155, & 185 3-1/2"-Models 25 & 25T, 45, 55, 75, 85 & Model 25 Process Meter 3-1/2"-Model 75 .16 DIA. DRILL THRU. ...