06715 Simpson, 06715 Datasheet - Page 11

Analog Panel Meters SHUNT 200 AMP 50 MV

06715

Manufacturer Part Number
06715
Description
Analog Panel Meters SHUNT 200 AMP 50 MV
Manufacturer
Simpson
Type
Current Shuntsr
Datasheets

Specifications of 06715

Equipment Type
Portable Shunt
Range
0 - 200
Accuracy
±1%
Current, Rating
200 A
Dimensions
6.00 in. L x 1.25 in. W x 1.60 in. D
Includes
5 ft. Leads
Resistance
0.065 Ohms
Screw Size
10-32
Voltage, Output
50 mV
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
• 1/8 DIN Indicator
• 3-1/2 or 4-1/2 digit bright red LED display
• Front panel pops off for easy decimal
• Only 3.12” (79mm) required behind panel
• Optional excitation output
• NEMA 4X enclosure optional
• Din Rail Adapter available
Mounting Requirements
The Falcon series 1/8 DIN indicators require a panel cutout of
1.77" (45mm) high by 3.62" (92mm) wide. To install the Falcon
into a panel cutout, remove the clips from the side of the meter.
Slide the meter through your panel cutout, then slide the mount-
ing clips back on the meter. Press evenly to ensure a proper fit.
Tighten screws.
point setting and display scaling
(page C1)
Dimensions
Specifications
DISPLAY
Type
Height
Decimal Point
Overrange indication
Polarity
POWER REQUIREMENTS
AC Voltages
DC Voltages
Power Consumption
ACCURACY @25°C
ENVIRONMENTAL
Operating Temperature
Storage Temperature
Relative Humidity
Temperature Coefficient
Warm-up Time
Response Time
NOISE REJECTION
NMRR
CMRR
A TO D CONVERSION
Technique
Rate
MECHANICAL
Bezel
Depth
Panel Cutout
Case Material
Weight
F45 DC Process/Voltage
F35 DC Process/Voltage
F45 DC Current
F35 DC Current
F45 AC Voltage/Current
F35 AC Voltage/Current
4.04”
3.59”
3.75
1.88
7-segment, red LED
0.56" (14.2mm)
3 or 4 position user-programmable,
internally or on the terminal block
most significant digit = "1"; other digits
blank
Automatic, with "-" indication,
"+" indication implied
120 or 220VAC, ±10% 50/60Hz
9-32DCV, ±1%
F35: 3VA, F45: 2VA
±0.02% of reading ± 1 count
750 ± 2 count
±0.1% of reading ± 1 count
750 ± 2 count
±0.05% of reading ±1 count
2A ± 5 counts
±0.1% of reading ± 1 count
2A ± 5 counts (45Hz-1KHz)
±0.5% of reading ± 35 counts (45Hz-1KHz)
±1% of reading ± 5 counts (45Hz-1KHz)
0 to 55°C
-10 to 60°C
0 to 85% non-condensing
(±0.1% of input ± 0.5 count)/°C
Less than 15 minutes
Less than 3 seconds
50dB, 50/60Hz
(w/1K unbalanced @ 60Hz) 90dB min.
Dual slope integration
3 samples per second, nominal
3.75" x 1.88" x .51"
2.94"
3.62" X 1.77"
94V-1, UL rated Noryl®
9.0oz (255.1g)
.51
2.94
5A ± 5 counts
92 mm
1.75
more >>
2.26