01300 Simpson, 01300 Datasheet - Page 12

Analog Panel Meters CUR XFMR DONUT 300/5

01300

Manufacturer Part Number
01300
Description
Analog Panel Meters CUR XFMR DONUT 300/5
Manufacturer
Simpson
Type
Inductiver
Datasheets

Specifications of 01300

Dimensions
27.94 mm W
Number Of Outputs
1
Primary Voltage Rating
300 V
Secondary Voltage Rating
5 V
Termination Style
Round Crimp Terminals
Accuracy
0.6 %
Current, Primary
300 A
Current, Ratio
300:5
Current, Secondary
5 A
Diameter, Inside
2.06 in.
Diameter, Outside
3.56 in.
Frequency Response
50 to 400 Hz
Function
Current
Material, Stud
Brass
Primary Type
Current
Range, Measurement
300 A
Standards
UL and CSA Approved
Technology
Inductive
Thickness
1.1 in.
Transformer Type
Donut
Turns Ratio
60:1
Input Current
300A
Transformer Mounting
Panel
Current Ratio
300
Leaded Process Compatible
No
Mounting Type
Donut
Output Current
5A
Peak Reflow Compatible (260 C)
No
Power Rating
2VA
Rohs Compliant
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
The primary wire passing through the core, or by wrapping the secondary wires leading to the meter
DC Process
Range Resolution Voltage
4-20mA
Range Resolution
1-5 DCV
0-10 DCV
Specifications for F35 Frequency Meters
DISPLAY
Type
Height
Overrange indication
POWER REQUIREMENTS
AC Voltages
Power Consumption
ACCURACY @25°C
INPUT LEVEL
Resolution:
ENVIRONMENTAL
Operating Temperature
Storage Temperature
Relative Humidity
Temperature Coefficient
Warm-up Time
Response Time
CONVERSION
Technique
Rate
ACCURACY @ 25°C
F35 ACA
F45 ACA
F35 ACV
F45 ACV
F35 DCA & DC Process
F45 DCA
F35 DCV
F45 DCV & DC Process
F35 Frequency
Inputs
200 Hz:
2 KHz:
1 uA
10mV
10mV
Impedance
10 M
10 M
Drop
0.2V
Input
(Unfused)
Maximum
Max Input
100 V
100 V
100mA
Input
7-segment, red LED
0.56" (14.2mm)
Most significant digit = "1"; other digits
blank
120 or 220VAC, ±10% 50/60Hz
2.5VA min./4VA max.
±0.2% of input ±0.2 Hz
±0.2% of input ± 2Hz
500mV to 750V RMS at 1.0MW imped-
ance OR 5V to 24V Square Wave (DC
offset 2V maximum)
200Hz = 0.1Hz
2kHz =1Hz
0 to 55°C
-10 to 60°C
0 to 85% non-condensing @ 40°C
(±0.05% of input ± 0.5 count)/°C
Less than 15 minutes
Less than 3 seconds
Frequency-to-voltage
3 samples per second, nominal
±1% of reading ± 5 counts (45Hz - 1 kHz)
±0.5% of reading ± 35 counts (45Hz - 1kHz)
±0.1% of reading ± 5 counts (45Hz - 1kHz)
±0.5% of reading ± 35 counts (45Hz - 1kHz)
±0.1% of reading ± 1 count
2A ± 5 counts (45Hz - 1 kHz)
±0.05% of reading ± 1 count
2A ± 5 counts 5A ± 5 counts
±0.1% of reading ± 1 count 750 ± 2 counts
±0.02% of reading ± 1 count 750 ± 2 counts
200 Hz: ±0.2% of input ± 0.2Hz
2kHz: ±0.2% of input ± 2Hz
DC Current
Input
Range
200 uA
2 mA
20 mA
200 mA
2 A
Resolution Voltage
100nA
100uA
10nA
10uA
1uA
Drop
200mV
200mV
200mV
200mV
200mV
Maximum
Overload
100mA
500mA
2.2A
DC Voltage
Input
Range Resolution Impedance Overload
200 mV
2 V
20 V
200 V
750 V
20mA
20mA
100uA
100mV
10uA
10mV
1mV
>100M
Specifications for F45 Temperature Meters
Input
10M
10M
10M
DISPLAY
Type
Height
Decimal Point
Overrange indication
Polarity
POWER REQUIREMENTS
AC Voltages
DC Voltages
Power Consumption
ENVIRONMENTAL
Operating Temperature
Storage Temperature
Relative Humidity
Warm-up Time
INPUTS
Thermocouple
RTD
Millivolt
Cold Junction Compensation
Error
Input Impedance
Lead Resistance Effect
Conversion Rate
Open Thermocouple Detection
AC/AC TRMS Voltage
Input
Range Resolution Impedance Overload
200 mV
2 V
20 V
200 V
750 V
1M
100mV
Maximum
100uV
10mV
10uV
100V
100V
250V
750V
1mV
50V
>100M
10M
10M
10M
Input
1M
Maximum
100V
100V
250V
750V
50V
7-segment, red LED
0.56" (14.2mm)
Jumper-selectable 2-position (correspon-
ding to resolution desired)
Most significant digit = "1"; other digits blank
Automatic, with "-" indication,
"+" indication implied
120 or 220 ACV, ±10% 50/60Hz
9-32 DCV, ±1%
3VA
0 to 55°C
-10 to 60°C
0 to 85% non-condensing
Less than 20 minutes
0.1°C/°C
10MW(typical)
4.0µV/100W
2-1/2 times per second
-1 on display, -40nA bias on thermocouple
J, K, E, T, R, and S
Platinum 100 (.00385 alpha), 2, 3 or 4 wire
±84mV reading of uncompensated mV
AC/AC TRMS Current
Input
Range
200 uA
2 mA
20 mA
200 mA
2 A
5 A
Resolution
100nA
100uA
10nA
10uA
1uA
1mA
Voltage
200mV
200mV
200mV
200mV
200mV
200mV
Drop
Maximum
Overload
20mA
20mA
100mA
500mA
2.2A
2.2A