M245-1-0-13-0 Simpson, M245-1-0-13-0 Datasheet - Page 3

no-image

M245-1-0-13-0

Manufacturer Part Number
M245-1-0-13-0
Description
Digital Panel Meters DCV 20mV 4.5 BL
Manufacturer
Simpson
Type
DC Voltmeterr
Datasheets

Specifications of M245-1-0-13-0

Equipment Type
DC Voltmeter
Input
20 V
Display Type
7 - Segment LCD
Accuracy
±0.04% %
Common Mode Rejection Ratio
90 dB (Min.) with 1 Kiloohms Unbalanced @ 60 Hz
Connection Type
Screw
Cut Out, Panel
0.88×2.68 "
Dimensions
2.84"L×2.36"D×0.95"H
Display Digit Height
0.5 "
Display Range
Limited
Display Resolution
1 mV
Function
Voltage
Input Impedance
10 Megohms
Material, Casing
Thermoplastic
Meter Type
Digital
Number Of Digits
4-1/2
Power Consumption
2.5⁄4.5 VA (Max.)
Primary Type
Electronic
Range, Measurement
20 VDC
Standards
UL Listed
Temperature, Operating
0 to +55 °C
Voltage, Input
750 V (Max.)
Voltage, Supply
85 to 250 VAC
Weight
3.5 Oz.
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
The Mini Max Voltage Indicator can be configured by making an entry for each box
Basic Unit
A company needs to monitor the power supply
voltage and load current of a 12 VDC motor.
Voltage: A Mini-Max DC Volt meter, configured
for the 20 volt range, is installed in parallel with
the power source. The IN HI is connected to
the positive lead of the power supply. The IN
LO is connected to the negative lead of the
power supply.
Current: A second Mini-Max DC Volt meter,
configured for the 200 millivolt range, is used
with a 100A/50mV shunt (sold separately) to
measure the load current.
The meter is first scaled to read 100.00 at
50mV, by applying a 50mV input to the meter
and adjusting R9 and R12 until the display
reads 100.00. The meter is connected to the
shunt, and the shunt is installed in series on the
negative leg of the power supply. The positive
NOTE: Display hold feature is configured at the factory only. Must specify at time of order.
Portable
Switchboard
NOTE: Special scaling is availbel fromt he factory at the time of ordering.
M245
Application Example
Ordering Information
Accessories
4-1/2 Digit Indicator
Display
0
1
Non Backlight
Negative Image Red
DPM Power Supply
0
2
External shunts enable digital panel
meters to indicate higher currents than
can be provided with self-contained
internal shunt meters.
installed in series with the load and
source. The shunts produce a DCmV
drop which is sent to the display unit.
The Mini-Max can be scaled to display
the actual current between the load and
the source.
portable and switchboard shunts.
Each portable shunt includes 5’ leads.
85-250VAC
9-32VDC
lead of the shunt is connected to the IN HI ter-
minal, and the negative lead connected to the
IN LO terminal.
IN HI
IN LO
200 mV DC UNIT
100 AMP SHUNT
Range
Simpson manufactures
11
12
13
14
200mV
2V
20V
200V
The shunt is
Excitation Output
25 DCmA max
0
1
2
output
None
12VDC
24VDC
POWER SUPPLY
DC MOTOR
-
The Mini-Max units will indicate the power sup-
ply voltage and load current of the motor.
+
Safety Symbols
Ordering Information
IN HI
Switchboard Shunts 50mV
Amps
Amps
100
150
200
100
150
200
250
300
400
500
Portable Shunts 50mV
IN LO
10
15
25
30
50
75
1
5
The WARNING sign denotes
a hazard. It calls attention to
a procedure, practice, or the
like, which, if not correctly
performed or adhered to,
could result in personal injury.
The CAUTION sign denotes a
hazard. It calls attention to an
operating procedure, prac-
tice, or the like, which, if not
correctly adhered to, could
result in damage to or
destruction of part or all of the
instrument.