2505-N Techspray, 2505-N Datasheet - Page 4

Chemicals CONDUCTIVE PEN

2505-N

Manufacturer Part Number
2505-N
Description
Chemicals CONDUCTIVE PEN
Manufacturer
Techspray
Type
Conductiver
Datasheet

Specifications of 2505-N

Product
Adhesives
Size
4.89 mL
Container
Pen
Chemical Component
Butyl Ethanoate/Propietary Polymer/Silver
Dispensing Method
Pen
Primary Type
Coating
Special Features
Repair
Temperature, Rating
-55 to +150 °C
Weight
4.89 ml
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
6. ACCIDENTAL RELEASE MEASURES
7. HANDLING AND STORAGE
Trace Technologies Conductive Pen
FLASHPOINT AND METHOD: > 22°C TAG CC
FLAMMABLE LIMITS: 1.7 to 7.6
AUTOIGNITION TEMPERATURE: > 425°C
GENERAL HAZARD: Vapors can travel to a source of ignition and flash back.
EXTINGUISHING MEDIA: Use alcohol foam, carbon dioxide, or water spray when fighting fires involving this
material.
HAZARDOUS COMBUSTION PRODUCTS: Smoke, fumes and oxides of carbon.
FIRE FIGHTING PROCEDURES: Evacuate area and fight fire from a safe distance.
FIRE FIGHTING EQUIPMENT: As in any fire, wear self-contained breathing apparatus pressure-demand,
(MSHA/NIOSH approved or equivalent) and full protective gear.
SMALL SPILL: Contain spill with dike to prevent entry into sewers.
LARGE SPILL: Clean up spills immediately, observing precautions in Protective Equipment section.
GENERAL PROCEDURES: Dike area to contain spill. Take precautions as necessary to prevent contamination
of ground and surface waters. Recover spilled material on adsorbent, such as sawdust or vermiculite, and sweep into
closed containers for disposal. After all visible traces, including vapors, have been removed thoroughly wet vacuum
the area. Do not flush to sewer. If area of spill is porous, remove as much contaminated earth, gravel, etc. as
necessary and place in closed containers for disposal.
SPECIAL PROTECTIVE EQUIPMENT: Only personnel equipped with proper respiratory and skin/eye
protection should be permitted in area. See Section 8 for details.
GENERAL PROCEDURES: Wash thoroughly after handling. Use only in a well ventilated area. Store in a cool
dry place.
HANDLING: Use with sufficient ventilation to keep employee exposure below recommended limits. Provide
adequate ventilation for storage, handling and use, especially for enclosed or low spaces. Avoid contact of liquid
with eyes and prolonged skin exposure. Do not allow product to contact open flame or electrical heating elements
because dangerous decomposition products may form.
STORAGE: Store away from heat.
STORAGE PRESSURE: Store at local atomspheric pressure.
STORAGE TEMPERATURE: Store in a cool place below ( 120 ) F (49 ) C.