Specifications
AC Input
Input Current
Inrush Current
Input Fuse
Efficiency
Output Voltage
Output Power
Ripple and Noise
Line/Load Regulation
Transient Response
Minimum Load
Case Material
Case Dimensions
Conducted Emissions
Radiated Emissions
Voltage Fluctuations
Static Discharge Immunity
Radiated RF Immunity
EFT/Burst Immunity
Line Surge Immunity
Conducted RF Immunity
Power Frequency Magnetic Field Immunity
Voltage Dip Immunity
Line Frequency Harmonics
CENB1090
Universal Input 90 Watt Series
ITE Switch-Mode Power Supply
•
•
•
•
•
•
•
•
•
100-240VAC Universal Input
Meets EISA2007, CEC Efficiency Level V,
Desktop Style
12V to 48V Single Output Models, up to 90W
Modified and Custom Designs Available
Regulated Output with Low Ripple
Impact-Resistant Polycarbonate Enclosure
No Load Power Consumption <0.5W
Meets UL/EN/IEC60950-1, 2
EU (EC) No 278/2009 Phase II
SL Power Electronics Corp
______________________________________________________________________________________________________________________________
3.15A, 250V Internal Primary Current Fuse is provided
•
6050 King Drive Ventura, CA 93003
129 x 77 x 40mm. See outline drawing
Meets International Efficiency Level V
RoHS
100-240VAC, +/-10%, 47-63 Hz, 1∅
nd
500µs max., 50% load step, typical
Edition
1% pk-pk max., 20MHz BW
Black 94V0 Polycarbonate
Line: +/- 1%, Load: +/-5%
60A peak @ 264Vac
100Vac: 2.0A
EMI/EMC Compliance
All Specifications are typical at nominal input, full load at 25
Not required
See chart
See chart
•
Phone 805.486.4565 • Fax 858.712.2040
MTBF
Hold-up Time
Overload Protection
Short Circuit Protection
Topology
Safety and EMC Approvals
Dielectric Withstand
Operating Temperature
Storage Temperature
Relative Humidity
Altitude
Output Connections
Weight
FCC Part 15, Class B, EN55022 Class B, EN55024
FCC Part 15, Class B, EN55022 Class B, EN55024
EN61000-3-3, Line Flicker
EN61000-4-2, 6kV Contact Discharge, 8kV air discharge
EN61000-4-3, 3V/m.
EN61000-4-4, 2kV/5kHz..
EN61000-4-5, 1kV differential, 2kV common-mode
EN61000-4-6, 3Vrms
EN61000-4-8, 3A/m
EN61000-4-11 crit. A, 100Vac 60Hz, 40%/5 cycles with 70% full load.
EN61000-3-2, Class A
Connector: Ault #3, 2.5mm barrel or #51, 6-pin Molex. See drawings.
3
Year Warranty
•
18 ms min. @ 115Vac, 60 ms min. @ 230 Vac
Email: info@slpower.com
Input-GND: 1,500 Vac, Output-GND: 500Vdc
Cable: 18AWG, 1,500mm, 4 conductor
Switching – Fixed Frequency Flyback
EN/IEC/CSA/UL60950-1, 2
°
C unless otherwise stated.
5% to 95%, non-condensing
>100,000 hours (calculated)
0° to 40°C, no derating
Input-Output: 4,242Vdc
•
www.slpower.com
EMC: See chart
0 to 10,000 ft
Hiccup Mode
-30 to +85°C
Hiccup Mode
nd
Edition
600g
1 of 2