1863220 Phoenix Contact, 1863220 Datasheet - Page 2

PLUG TERM BLOCK 9POS 3.5MM

1863220

Manufacturer Part Number
1863220
Description
PLUG TERM BLOCK 9POS 3.5MM
Manufacturer
Phoenix Contact
Series
COMBICON MCVRr
Type
Wire to Wirer
Datasheets

Specifications of 1863220

Wire Gauge
14-30 AWG
Current
8A
Terminal Block Type
Plug, Female Sockets
Positions Per Level
9
Pitch
0.138" (3.50mm)
Number Of Levels
1
Plug Wire Entry
180°
Termination
Screw
Voltage
300V
Mounting Type
Free Hanging (In-Line)
Color
Green
Product
Pluggable Terminal Blocks
Number Of Positions / Contacts
9
Wire Gauge Range
28-16
Current Rating
8 A
Voltage Rating
160 V
Mounting Style
Through Hole
Mounting Angle
90 Deg
Termination Style
Screw
Flammability Rating
UL 94 V-0
Height
12.5 mm
Wire Gauge Max (awg)
16
Wire Gauge Min (awg)
28
Agency Approvals
UL, cULus, VDE
Brand/series
Combicon
Cross-section Area
1.5 mm²
Current, Rating
8 A
Dimensions
32.3 mm L x 10.4 mm W x 19.1 mm H
Length, Stripping
7 mm
Level
Single Level
Material, Insulation
PA
Number Of Poles
9 Poles
Phoenix Part Number
MCVR 1.5/ 9-ST-3.5
Pin Spacing
3.5 mm
Primary Type
PCB
Screw Thread
M2
Torque, Tightening
0.22 Nm (Min.)
Voltage, Rating
300 V
Voltage, Surge
2.5 kV
Wire Entry
Front
Wire, Awg
30-14
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Header Orientation
-
Features
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
MCVR 1.5/ 9-ST-3.5
MCVR 1,5/ 9-ST-3,5
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1863220
PHOENIX CONTACT Inc., USA
http://www.phoenixcon.com
Screw thread
Tightening torque, min
Tightening torque max
Technical data
Range of articles
Insulating material group
Rated surge voltage (III/3)
Rated surge voltage (III/2)
Rated surge voltage (II/2)
Rated voltage (III/2)
Rated voltage (II/2)
Connection in acc. with standard
Nominal current I
Nominal voltage U
Nominal cross section
Maximum load current
Insulating material
Inflammability class acc. to UL 94
Internal cylindrical gage
Stripping length
Nominal voltage, UL/CUL Use Group B
Nominal current, UL/CUL Use Group B
Nominal voltage, UL/CUL Use Group D
Nominal current, UL/CUL Use Group D
Connection data
Conductor cross section solid min.
Conductor cross section solid max.
Conductor cross section stranded min.
Conductor cross section stranded max.
Conductor cross section stranded, with ferrule
without plastic sleeve min.
Conductor cross section stranded, with ferrule
without plastic sleeve max.
Conductor cross section stranded, with ferrule
with plastic sleeve min.
N
N
Order No.: 1863220
M2
0.22 Nm
0.25 Nm
MCVR 1,5/..-ST
I
2.5 kV
2.5 kV
2.5 kV
160 V
320 V
EN-VDE
8 A
160 V
1.5 mm²
8 A (with 1.5 mm
PA
V0
A1
7 mm
300 V
8 A
300 V
8 A
0.14 mm²
1.5 mm²
0.14 mm²
1.5 mm²
0.25 mm²
1.5 mm²
0.25 mm²
2
conductor cross section)
Jun 12, 2011
Page 2 / 5

Related parts for 1863220