141-0403-012 Emerson Network Power, 141-0403-012 Datasheet

CONN PLUG SMA STR CRIMP RG-316

141-0403-012

Manufacturer Part Number
141-0403-012
Description
CONN PLUG SMA STR CRIMP RG-316
Manufacturer
Emerson Network Power
Series
SMAr
Datasheet

Specifications of 141-0403-012

Connector Style
SMA
Connector Type
Plug, Male Pins
Contact Termination
Crimp and Solder
Impedance
50 Ohm
Mounting Type
Free Hanging (In-Line)
Fastening Type
Threaded
Cable Group
RG-161, 174, 188, 316, LMR-100
Frequency - Max
12.4GHz
Frequency-max
12.4GHz
Body Style
Straight
Cable Type
RG 161/U, RG 174, RG 188, RG 316, LMR 100, HPF 100, RF 100
Features
Stainless Steel connector
Frequency Range
0 GHz to 26.5 GHz
Housing Material
Stainless Steel
Mounting Angle
Straight
Rf Series
SMA
Product
Various Connectors
Gender
Male
Contact Plating
Gold
Shell Plating
Passivated Stainless Steel
Termination Style
Crimp
Maximum Frequency
26.5 GHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Color
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
J875
Stainless Steel SMA Connectors
Product Catalog
Connectivity....for
Business-Critical Continuity

Related parts for 141-0403-012

141-0403-012 Summary of contents

Page 1

Stainless Steel SMA Connectors Product Catalog Connectivity....for Business-Critical Continuity ...

Page 2

Stainless Steel SMA Connectors Johnson ® Stainless Steel SMA Connectors meet or exceed the performance requirements of MIL-PRF-39012. All designs are based on 50 ohm system impedance per MIL-STD-348, and operate at frequencies up to 26.5 GHz. Applications • Antennas ...

Page 3

... Working Voltage: (Vrms maximum) RG-316, LMR-100, 195 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250 RG-58, RG-142, .086 Semi-Rigid, Uncabled receptacles, .141 Semi-Rigid w/o contact 335 .141 Semi-Rigid with contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500 Dielectric Withstanding Voltage: (Vrms minimum at sea level) Connectors for RG-316, LMR-100, 195 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

Page 4

... RF High Potential Withstanding Voltage: (Vrms minimum, tested at 4 and 7 MHz) Connectors for RG-316, LMR-100, 195 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connectors for RG-58, RG-142, .086 Semi-Rigid, .141 Semi-Rigid cable w/o contact, Uncabled receptacles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connectors for .141 Semi-Rigid with contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000 Insulation Resistance: 5000 Megohms minimum Contact Resistance: (milliohms maximum) Center contact (straight cabled connectors and Uncabled receptacles) ...

Page 5

... Cable Retention: (minimum*) Connectors for RG-316, LMR-100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Connectors for RG- Connectors for RG-142 Cabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Connectors for .086 Semi-Rigid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Connectors for .141 Semi-rigid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Connectors for LMR-195 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . cable breaking strength, whichever is less ENVIRONMENTAL SPECIFICATIONS (Meets or Exceeds the Applicable Paragraph of MIL-PRF-39012) Temperature Range: -65°C to +165°C Thermal Shock: MIL-STD-202, Method 107, Condition B (except +85° ...

Page 6

Stainless Steel SMA Connectors MATING ENGAGEMENT FOR STAINLESS STEEL SMA SERIES PER MIL-STD-348A 6 MOUNTING HOLES Fig 1 Connectivity....for Business-Critical Continuity Fig 2 Inches (Millimeter) ...

Page 7

... Cable Tpe RG-405, .086 Semi-Rigid RG-402, .141 Semi-Rigid Assembly instructions page 16 Straight Solder Type Plug - without Contact, Thread-on Nut Connector Interface for .141 Cable Cable Type RG-402, .141 Semi-Rigid Assembly instructions page 15 Straight Solder Type Plug with Captivated Solderless Contact, Captive Nut and Thick Wall Interface Cable Type RG-405, ...

Page 8

... Stainless Steel SMA Connectors Straight Solder Type Jack Cable Type RG-405, .086 Semi-Rigid RG-402, .141 Semi-Rigid Assembly instructions page 16 Straight Solder Type Bulkhead Jack with O-Ring Cable Type RG-405, .086 Semi-Rigid RG-402, .141 Semi-Rigid Assembly instructions page 16 Straight Solder Type Bulkhead Jack with Captivated ...

Page 9

... RG-55/U, 142, 223, 400 Assembly instructions page 14 Inches (Millimeter) Stainless Steel SMA Connectors VSWR & Freq. Range Passivated 1.15+.02f (0-12.4 GHz) 141-0403-012 1.15+.02f (0-12.4 GHz) 141-0404-012 1.15+.01f (0-12.4 GHz) 141-0407-012 1.15+.01f (0-12.4 GHz) 141-0408-012 VSWR & Freq. Range Passivated 1 ...

Page 10

... Straight PC Mount Jack Receptacle Freq. Range 0-18 GHz Mounting hole layout Figure 2 on page 6 Rear Mount Bulkhead Jack Receptacle Freq. Range 0-18 GHz Mounting hole layout Figure 1 on page 6 10 Gold Plated 141-0701-301 Gold Plated 141-0701-201 Passivated 141-0701-402 Connectivity....for Business-Critical Continuity Inches (Millimeter) ...

Page 11

... Connectivity....for Business-Critical Continuity 2-Hole Flange Mount Jack Receptacle - Flush Dielectric Freq. Range 0-18 GHz 4-Hole Flange Mount Jack Receptacle - Flush Dielectric Freq. Range 0-18 GHz Inches (Millimeter) Stainless Steel SMA Connectors Passivated 141-0701-602 Passivated 141-0701-612 11 ...

Page 12

... Stainless Steel SMA Connectors 2-Hole Flange Mount Jack Receptacle - Extended Dielectric VSWR & Freq. Range 1.15+.02f (0-18 GHz) 4-Hole Flange Mount Jack Receptacle - Extended Dielectric VSWR & Freq. Range 1.15+.02f (0-18 GHz) 12 Passivated 141-0701-622 Passivated 141-0701-632 Connectivity....for Business-Critical Continuity Inches (Millimeter) ...

Page 13

... Semi-Rigid Cable Clamp Inserts for .141" OD Cable Soldering Mating Fixture for SMA Jack Connectors Complete Center Conductor Pointing Tool for .086" OD Cable Complete Center Conductor Pointing Tool for .141" OD Cable Bushing for .086" OD Cable Conductor Pointing Tool Bushing for .141" OD Cable Conductor Pointing Tool ...

Page 14

... Part No. RG-316/U, 161, 174, 188; LMR-100 141-0303-412 RG-316 DS, 188 DS 141-0304-412 RG-58/U, 141, 303 141-0307-412 RG-55/U, 142, 223, 400 141-0308-412 RG-316/U, 161, 174, 188; LMR-100 141-0403-012 RG-316 DS, 188 DS 141-0404-012 RG-58/U, 141, 303 141-0407-012 RG-55/U, 142, 223, 400 141-0408-012 14 Crimp Hex .128 (3.25) ...

Page 15

... Solder body to cable. Use a minimum amount of heat to minimize cable insulation movement. Trim expanded insulation flush with front of body or fixture body and cable during soldering to prevent cable insulation expansion. 4. Thread coupling nut over body. Cable Type Part No. RG-402/U (.141 Semi-Rigid) 141-0694-012 Inches (Millimeter) Stainless Steel SMA Connectors 15 ...

Page 16

... Solder body to cable. Use a minimum amount of heat to minimize cable insulation movement. Cable Type Part No. RG-405/U (.086 Semi-Rigid) 141-0593-001 141-0593-401 141-0693-002 RG-402/U (.141 Semi-Rigid) 141-0594-001 141-0594-401 141-0694-002 16 “A” .070 (1.78) .070 (1.78) .070 (1.78) .085 (2.16) ...

Page 17

... Allow the assembly to cool before removing the connector from the fixture Cable Type Part No. RG-405/U (.086 Semi-Rigid) 141-0593-421 141-0693-062 RG-402/U (.141 Semi-Rigid) 141-0594-421 141-0694-062 Inches (Millimeter) Stainless Steel SMA Connectors 17 ...

Page 18

... Shrink heat shrink tubing over crimp sleeve if applicable. Cable Type Part No. RG-316/U, 161, 174, 188; LMR-100 141-0403-102 RG-316 DS, 188 DS 141-0404-112 RG-58/U, 141, 303 141-0407-102 RG-55/U, 142, 223, 400 141-0408-102 18 Crimp Hex .128 (3.25) .151 (3.83) ...

Page 19

... Connectivity....for Business-Critical Continuity COMPETITOR CROSS REFERENCE JOHNSON HUBER SUHNER 141-0403-012 11SMA-50-2-55C 141-0404-012 11SMA-50-2-56C 141-0407-012 11SMA-50-3-55C 141-0408-012 11SMA-50-3-56C 141-0403-102 16SMA-50-2-55C 141-0404-102 16SMA-50-2-56C 141-0407-102 16SMA-50-3-55C 141-0408-102 16SMA-50-3-56C 141-0693-002 11SMA-50-2-65 141-0694-002 11SMA-50-3-65 141-0694-012 11SMA-50-3-64 141-0693-062 11SMA-50-2-65 141-0694-062 11SMA-50-3-65 141-0303-412 141-0304-412 141-0307-412 141-0308-412 141-0593-001 ...

Page 20

... Connectivity Inbound Power DC Power Systems Integrated Cabinet Solutions Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2006 Emerson Electric Co JC0606-SS About Emerson Network Power Connectivity Solutions Emerson Network Power Connectivity Solutions, an Emerson business, serves the needs of ...

Related keywords