DA-EU Emerson Network Power, DA-EU Datasheet - Page 2

PLUG AC EUROPE 2 PRONG

DA-EU

Manufacturer Part Number
DA-EU
Description
PLUG AC EUROPE 2 PRONG
Manufacturer
Emerson Network Power
Series
DA12-M, DA18-Mr
Datasheet

Specifications of DA-EU

Accessory Type
European Blade
Mounting Style
Wall, Interchangeable Plug
Input Voltage (nominal)
90 VAC to 264 VAC
Number Of Outputs
1
Output Power Rating
18 W
Output Voltage (channel 1)
15 V
Output Current (channel 1)
1.2 A
Ac Plug Included/required
Required
Commercial/medical
Commercial/Medical
For Use With
454-1405 - PLUG AC INTERCHANGE ALL COUNTRY454-1396 - ADAPTER WALLMOUNT 18W 15V OUT454-1393 - ADAPTER WALLMOUNT 12W 12V OUT454-1390 - ADAPTER WALLMOUNT 10W 5V OUT454-1389 - ADAPTER WALLMOUNT 10W 5V OUT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
DA12-M, DA18-M Series
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
454-1408
Environmental Specifications
AC Plug Configuration
for Fixed Plug
Operating temperature: 0 ° to +40 °C ambient
Storage temperature:
Electromagnetic
susceptibility:
Humidity:
Vibration:
U.S. 2-prong
Europe 2-prong
United Kingdom 3-prong
Australia 2-prong
Ordering Information - DA12 Adapter
* Interchangeable version - AC Plugs must be purchased separately to be used with DA12-120MP-M and DA12-050MP-M
** 2.1 mm x 5.5 mm barrel plug
Ordering Information - DA12 Interchangeable Plug
Model Number
DA-US
DA-EU
DA-UK
DA-AU
DA-C8
DA-All Includes all of the above except for C8
1. Peak current lasting < 30 seconds with a maximum 10% duty cycle.
2 . At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3 . Peak-to-peak with 20 mHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
4 . Power supplies will operate with no-load.
DA12-050MP-M2.1**
DA12-120MP-M*
DA12-050MP-M*
Model Number
DA12-120UK-M
DA12-120AU-M
DA12-050UK-M
DA12-050AU-M
DA12-120US-M
DA12-120EU-M
DA12-050US-M
DA12-050EU-M
-40 °C to +85 °C
Designed to meet EN55024
Operating; non-condensing 5% to 95% RH
Frequency/PSD: 5 - 350 Hz
Acceleration:
Duration:
Maximum Power
US
EU
UK
AU
12 W
12 W
12 W
12 W
12 W
10 W
10 W
10 W
10 W
10 W
10 W
350 - 500 Hz - 6dB/Oct.
500 Hz
0.21 gRMS
20 min per second
Voltage
Output
12.0 V
12.0 V
12.0 V
12.0 V
12.0 V
5.0 V
5.0 V
5.0 V
5.0 V
5.0 V
5.0 V
0.0001 g
0.00005g
Minimum Load Maximum Load
2
/Hz
2
/Hz
0.2 A
0.2 A
0.2 A
0.2 A
0.2 A
0.2 A
0.2 A
0.2 A
0.2 A
0.2 A
0.2 A
AC Plug Configuration
for Interchangeable Plug
U.S. 2-prong
Europe 2-prong
United Kingdom 3-prong
Australia 2-prong
C8 - 2 receptacle
1.0
1.0
1.0
1.0
1.0
2.0
2.0
2.0
2.0
2.0
2.0
DA-US
DA-EU
DA-UK
DA-AU
DA-C8
Embedded Power for
Business-Critical Continuity
Regulation
± 5%
± 5%
± 5%
± 5%
± 5%
± 5%
± 5%
± 5%
± 5%
± 5%
± 5%
2
P/P (PARD)
120 mV
120 mV
120 mV
120 mV
120 mV
Ripple
50 mV
50 mV
50 mV
50 mV
50 mV
50 mV
Rev.04.11.11_105
DA12-M Series
3
2 of 5