2866514 Phoenix Contact, 2866514 Datasheet
2866514
Specifications of 2866514
Related parts for 2866514
2866514 Summary of contents
Page 1
... The floating signal contact and LED immediately indicate the loss of redundancy. Make sure you always use the latest documentation. It can be downloaded from the product at www.phoenixcontact.net/catalog. © PHOENIX CONTACT 2010-04-23 Features – 100% decoupling of power supply units connected in parallel – ...
Page 2
... Table of contents 2 Table of Contents 1 Description .................................................................................................................................. Features.....................................................................................................................................................................1 2 Table of contents......................................................................................................................... 3 Ordering data .............................................................................................................................. 4 Technical data............................................................................................................................. 5 Structure...................................................................................................................................... 6 Block diagram ............................................................................................................................. 7 Safety and warning notes ............................................................................................................ 8 Installation ................................................................................................................................... 9 Installation position...................................................................................................................... 10 Mounting on DIN rails .................................................................................................................. Assembly ...................................................................................................................................................................8 Removing...................................................................................................................................................................8 11 Input ............................................................................................................................................ 12 Output ......................................................................................................................................... 13 Function ...................................................................................................................................... Input/output ................................................................................................................................................................9 Signaling ..................................................................................................................................................................10 Thermal behavior .....................................................................................................................................................10 104278_en_00 TRIO-DIODE/12-24DC/2X10/1X20 PHOENIX CONTACT ...
Page 3
... Max. permissible relative humidity (operation) Vibration (operation) Shock Pollution degree in acc. with EN 50178 Climatic class 104278_en_00 TRIO-DIODE/12-24DC/2X10/1X20 Type Order No. TRIO-DIODE/12-24DC/2X10/1X20 2866514 ... ... Approx. 0 (-25°C to +55° (-25°C to +55° (-25°C to +40° (-25°C to +40°C) From +55°C to 70°C: 2.5% per Kelvin > Varistor Yes, with integrated diode, < ...
Page 4
... Conductor to conductor) Comments Criterion B EN 61000-4-6 Input/output Level 3 Frequency range 150 kHz ... 80 MHz Voltage 10 V Comments Criterion A EN 55011 (EN 55022) Class B, area of application: Industry and residential EN 55011 (EN 55022) Class B, area of application: Industry and residential TRIO-DIODE/12-24DC/2X10/1X20 PHOENIX CONTACT 4 ...
Page 5
... DC output approximately 0.5 V < DC input 6 Universal snap-on foot for EN DIN rails 6 solid Input 0.2 - 2.5 0.2 - 2.5 Output 0 Signal 0.2 - 2.5 0 ... ... Screw connection 9 mm 0.5 V < DC input Screw connection [mm ] AWG [Nm] stranded Torque 0.4 - 0.5 0 0 0.4 - 0.5 5 PHOENIX CONTACT ...
Page 6
... Before startup please ensure: The connection must be carried out by a competent person and protection against electric shock guaranteed. All input and output lines are dimensioned according to the maximum output current of the device or separately protected. Sufficient convection must be guaranteed. 104278_en_00 TRIO-DIODE/12-24DC/2X10/1X20 + + PHOENIX CONTACT ...
Page 7
... To ensure sufficient convection, we recommend the following minimum spacing be used between modules for vertical installation and 0 cm for horizontal installation. The redundancy module can be snapped onto all DIN rails in accordance with EN 60715 and must be mounted horizontally (connecting terminal blocks on top and bottom). PHOENIX CONTACT 7 ...
Page 8
... You can fasten the connection cables to the housing using cable binders. Make sure that the connecting cables and cable binders used are designed for the surface temperatures on the housing. When tightening the cable binders, the insulation of the connecting cables must not be damaged. PHOENIX CONTACT 8 ...
Page 9
... This is necessary because the maximum current carrying capacity per input must not be exceeded. For connecting the redundancy module to the power supply unit, OUT+ we recommend using two identical connecting cables (cable length/cable cross sections). TRIO-DIODE/12-24DC/2X10/1X20 PHOENIX CONTACT 9 ...
Page 10
... PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany • Phone: +49-(0) 5235-3-00 104278_en_00 PHOENIX CONTACT • P.O.Box 4100 • Harrisburg • PA 17111-0100 • USA • Phone: +717-944-1300 Signaling A floating relay contact and "Redundancy OK" LED are available for monitoring redundancy. In normal operation where input voltage > ...