USB2502-HT SMSC, USB2502-HT Datasheet - Page 18

CONTROLLER, HUB, USB2.0, 2PORT, 36QFN

USB2502-HT

Manufacturer Part Number
USB2502-HT
Description
CONTROLLER, HUB, USB2.0, 2PORT, 36QFN
Manufacturer
SMSC
Datasheet

Specifications of USB2502-HT

Supply Voltage Range
1.62V To 1.98V, 3V To 3.6V
Digital Ic Case Style
TQFP
No. Of Pins
48
Operating Temperature Range
0°C To +70°C
Supply Voltage Max
3.6V
Supply
RoHS Compliant
Package / Case
TQFP
Data Rate Max
480Mbps
Rohs Compliant
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
USB2502-HT
Manufacturer:
Standard
Quantity:
590
Part Number:
USB2502-HT
Manufacturer:
SMSC
Quantity:
20 000
Revision 2.3 (08-27-07)
5.1.1.13
5.1.1.14
5.1.1.15
5.1.1.16
5.1.1.17
5.1.1.18
5.1.1.19
5.1.2
When Dynamic Power switching is enabled, the Hub detects the availability of a local power source
by monitoring the external SELF_PWR pin. If the Hub detects a change in power source availability,
the Hub immediately disconnects and removes power from all downstream devices and disconnects
the upstream port. The Hub will then re-attach to the upstream port as either a Bus-Powered Hub (if
local-power in unavailable) or a Self-Powered Hub (if local power is available).
This field is set by the OEM using either the SMBus or EEPROM interface options.
Over-Current Timer
The time delay (in 2ms increments) for an over-current condition to persist before it is reported to the
Host.
This field is set by the OEM using either the SMBus or EEPROM interface options.
Self-Powered Max Power
When in Self-Powered configuration, Sets value in 2mA increments.
This field is set by the OEM using either the SMBus or EEPROM interface options.
Bus-Powered Max Power
When in Bus-Powered configuration, Sets value in 2mA increments.
This field is set by the OEM using either the SMBus or EEPROM interface options.
Self-powered Hub Controller Current
When in Self-Powered configuration, Maximum current requirements of the Hub Controller in 2mA
increments.
This field is set by the OEM using either the SMBus or EEPROM interface options.
Bus-Powered Hub Controller Current
When in Bus-Powered configuration, Maximum current requirements of the Hub Controller in 2mA
increments.
This field is set by the OEM using either the SMBus or EEPROM interface options.
Power-On Timer
Time (in 2ms intervals) from the time power-on sequence begins on a port until power is good on that
port. System software uses this value to determine how long to wait before accessing a powered-on
port.
This field is set by the OEM using either the SMBus or EEPROM interface options.
Power Switching Polarity
The selection of active state “polarity” for the PRTPWR2 pin is made by a strapping option only.
VBus Detect
According to Section 7.2.1 of the USB 2.0 Specification, a downstream port can never provide power
to its D+ or D- pull-up resistors unless the upstream port’s VBUS is in the asserted (powered) state.
The VBUS_DET pin on the Hub monitors the state of the upstream VBUS signal and will not pull-up
the D+ or D- resistor if VBUS is not active. If VBUS goes from an active to an inactive state (Not
Powered), Hub will remove power from the D+ or D- pull-up resistor within 10 seconds.
DATASHEET
18
2-Port USB 2.0 Hub Controller
SMSC USB2502
Datasheet

Related parts for USB2502-HT