A9-30-10-230V-50HZ ABB, A9-30-10-230V-50HZ Datasheet - Page 26

CONTACTOR, 3PST-NO, 230VAC, 7A, PANEL

A9-30-10-230V-50HZ

Manufacturer Part Number
A9-30-10-230V-50HZ
Description
CONTACTOR, 3PST-NO, 230VAC, 7A, PANEL
Manufacturer
ABB
Datasheet

Specifications of A9-30-10-230V-50HZ

No. Of Poles
3
Contact Configuration
3PST-NO
Relay Mounting
Panel
Coil Voltage Vac Nom
230V
Length/height, External
74mm
Width
44mm
Nom Operating Power
4kW
External Width
44mm
Operating Voltage
690VAC
Switching Power Ac1
4kW
Switching Power Ac3
4kW
Switching Current Ac1
25A
Switching Current Ac3
9A
Load Current Inductive
9A
Load Current Resistive
25A
ABB LIMITED
AF 75-40-00
www.abb.com/lowvoltage
a.c. / d.c. Operated - Large Voltage Range
Electronic Coil Interface
Rated operational
current
AC-1
A
4 N.O. main poles
70
100
2 N.O. + 2 N.C. main poles
70
125
Voltage
48 ... 130
100 ... 250
(1) The connection polarities indicated close to the coil terminals must be respected: A1 for the positive pole and A2 for the negative pole.
Remark for AF 45 ... AF 75 4-pole contactors built with 2 N.O. + 2 N.C. main poles
These contactors are suitable for controlling 2 separate circuits, i.e. 2 loads with 2 separate supplies, or 1
circuit comprising 2 separate loads with a single supply (+ diagrams below). When the contactor operates
there is no mechanical overlapping between the N.O. poles and the N.C. poles: BREAK before MAKE.
Block Diagrams
Electromagnetic compatibility:
Ed.2) and European standards EN 60947-1, 60947-4-1.
Notice: This product has been designed for environment A. Use of this product in environment B may
cause unwanted electromagnetic disturbances in which case the user may be required to take adequate
mitigation measures.
Definitions:
Environment A: "Mainly relates to low-voltage non public or industrial networks/locations/installations
(+ EN 50082-2 article 4) including highly disturbing sources".
Environment B: "Mainly relates to low-voltage public networks (+ EN 50082-1 article 5) such as residential,
commercial and light industrial locations/installations. Highly disturbing sources such as arc welders are not
covered by this environment".
AF 45 ... AF 75 4-pole Contactors
125
Coil voltages
AF... contactors comply with international standards IEC 60947-1 (2000-10-Ed.3.1), 60947-4-1 (2000-11-
40 °C
Single supply and 2 separate loads
V - 50/60Hz
These contactors are not suitable for a reversing starter or star-delta starter or for controlling a
single load from 2 separate supplies.
email marketing.info@gb.abb.com
Auxiliary contacts
fitted
Voltage
20 ... 60
48 ... 130
100 ... 250
V d.c.
Telephone 02476 368551
110
110
110
110
110
H
Footprint
92
92
92
92
92
W
2 separate supplies and 2 separate loads
120
120
120
120
120
D
Weight
kg
1.420
1.420
1.420
1.420
1.420
Facsimile 02476 368401
Return to main index
Order code
state coil voltage
AF 45-40-00
AF 50-40-00
AF 75-40-00
AF 45-22-00
AF 75-22-00
2/26