CGDP2020B5 CARLO GAVAZZI, CGDP2020B5 Datasheet

Definite Purpose Contactor

CGDP2020B5

Manufacturer Part Number
CGDP2020B5
Description
Definite Purpose Contactor
Manufacturer
CARLO GAVAZZI
Datasheet

Specifications of CGDP2020B5

No. Of Poles
2
Contact Configuration
DPST
Contactor Direction
Non Reversing
Coil Voltage Vac Nom
24V
Relay Terminals
Screw
Contact Voltage Ac Nom
660V
Wire Size (awg)
14-4
Contact Current Max
20A
Operating Voltage
660VAC
Switching Power Ac1
3hp
Switching Current Ac1
30A
Load Current Inductive
20A
Load Current Resistive
30A
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Type Selection
Coil Voltage
B: 24 VAC
F: 120 VAC
K: 208-240 VAC
Y: 277 VAC
1 pole, 1 pole + shunt, 2 pole
Type CGDP
Product Description
Power contactors specifically designed for the OEM when
performance and cost must be optimized. Perfect choice for
HVAC, lighting, pumps, compressors, pools, spas, welders etc.
Specifications are subject to change
Series
CGDP:
Definite Purpose Contactor
Pole Configuration
1 : 1-pole
15: 1-pole + shunt
2 : 2-pole
Coil Frequency
5: 50/60 Hz
05.03.2007)
Accessories
Blank: with arc cover
Amperage Rating
20: 20 A
25: 25 A
30: 30 A
40: 40 A
S: without arc plate
Ordering Key
Series
Pole Configuration
Amperage Rating
Power Terminals
Coil Voltage
Coil Frequency
Accessories
(standard)
• Definite Purpose Contactor
• Switching up to 40A inductive,
• Coils up to 277VAC, 50/60 Hz
• cRUus, CSA, CE, and RoHS
• Faston (standard) or box lug terminals
• Cost effective
50A resistive
CGDP 20 20 LN F 5 S
Blank:
Power Terminals
LN:
M:
N:
L:
Screw terminal,
power and load
side (standard)
Without fast-on
terminals
Lug terminal, power
and load side
Lug terminals
without fast-on
Power side screw,
load side lug
1

Related parts for CGDP2020B5

CGDP2020B5 Summary of contents

Page 1

... Type CGDP Product Description Power contactors specifically designed for the OEM when performance and cost must be optimized. Perfect choice for HVAC, lighting, pumps, compressors, pools, spas, welders etc. Type Selection Series Pole Configuration CGDP 1-pole Definite Purpose Contactor ...

Page 2

... Definite Purpose Contactors 1 pole, 1 pole + shunt, 2 pole Type CGDP Technical Specifications: Catalogue Number 1 Pole 1 Pole + Shunt 2 Pole Rated Insulation (Ui) and Operational Voltage (Ue) UL/IEC Rated Initial Dielectric Strength Rated Thermal Current (lth) Full Load Amps (FLA) Locked Rotor Amps (LRA)A ARI 780/790 ...

Page 3

... Definite Purpose Contactors 1 pole, 1 pole + shunt, 2 pole Type CGDP Coil Characteristics: CGDP2020 to 2040: 24V 50/60Hz Voltage Frequency Pick-up Voltage Drop-out Voltage Inrush VA 30.2 27.5 Sealed VA 6.5 4.8 Sealed 3.6 3.0 Watts Endurance Data: Mechanical: 1 million Electrical: AC3 250K Environmental Data: Temperature Range: Storage and operating: -10º ...

Page 4

... Definite Purpose Contactors 1 pole, 1 pole + shunt, 2 pole Type CGDP Connection Diagram: One pole CGDP10xx Other Information: Accessories: None Compliancy: Agency Approvals: Specifications are subject to change One pole + shunt CGDP15xx 05.03.2007) Two pole CGDP20xx ...

Related keywords