AF12Z-30-01-21 ABB, AF12Z-30-01-21 Datasheet - Page 13

no-image

AF12Z-30-01-21

Manufacturer Part Number
AF12Z-30-01-21
Description
CONTACTOR,3P,60V,5.5KW
Manufacturer
ABB
Datasheet

Specifications of AF12Z-30-01-21

Operating Voltage
60V
Switching Power Ac3
5.5kW
Switching Current Ac1
28A
Switching Current Ac3
12A
No. Of Poles
3
Contacts
1NC
Relay Mounting
DIN Rail
Coil Voltage Vac Nom
60V
Coil Voltage Vdc
RoHS Compliant
Contact Configuration
1NC
Rohs Compliant
Yes
Coil Voltage Vdc Nom
60V
Svhc
No SVHC
Auxiliary Contact Blocks
Accessories for AF09 ... AF38 3-pole Contactors
Technical Data
Types
Contact Utilization Characteristics according to IEC
Standards
Rated insulation voltage U
Rated impulse withstand voltage U
Rated operational voltage U
Conventional thermal current I
Rated frequency limits
Rated operational current I
acc. to IEC 60947-5-1
Making capacity
Breaking capacity
Rated operational current I
acc. to IEC 60947-5-1
Short-circuit protection gG type fuse
Rated short-time withstand current Icw
θ = 40 °C
Minimum switching capacity
with failure rate acc. to IEC 60947-5-4
Heat dissipation per pole at 6 A
Mechanical durability
Max. electrical switching frequency
Contact Utilization Characteristics according to UL / CSA
Standards
Rated insulation voltage U
Max. rated voltage
Pilot duty
Connecting Characteristics
Screw terminals
All terminals
Connecting capacity (min. ... max.)
Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Screwdriver type
Tightening torque
AC thermal rated current
AC maximum volt-ampere making
AC maximum volt-ampere breaking
DC thermal rated current
DC maximum volt-ampere making-breaking
Capacity acc. to UL/CSA
Stripping length
6
L
Rigid solid
Flexible with non insulated ferrule
Flexible with insulated ferrule
Bars or lugs
acc. to IEC 60947-5-1
acc. to IEC 60947-5-1
i
i
e
e
acc. to IEC 60947-5-1
e
Number of operating cycles
Max. switching frequency
/ AC-15
/ DC-13
max.
th
- θ ≤ 40 °C
imp
220-240 V 50/60 Hz
400-440 V 50/60 Hz
24-127 V 50/60 Hz
500 V 50/60 Hz
690 V 50/60 Hz
for AC-15
for DC-13
110 V DC
125 V DC
220 V DC
250 V DC
400 V DC
500 V DC
600 V DC
24 V DC
48 V DC
72 V DC
for 1.0 s
for 0.1 s
1 or 2 x
L <
1 x
2 x
1 x
2 x
1 x
2 x
1-pole CA4, 1-pole CC4, 4-pole CA4, 2-pole CAT4, 2-pole CAL4
IEC 60947-5-1 and EN 60947-5-1
690 V
6 kV
24 ... 690 V
16 A
25 ... 400 Hz
6 A
4 A
3 A
2 A
2 A
10 x I
10 x I
6 A / 144 W
2.8 A / 134 W
1 A / 72 W
0.55 A / 60 W
0.55 A / 69 W
0.27 A / 60 W
0.27 A / 68 W
0.15 A / 60 W
0.13 A / 65 W
0.1 A / 60 W
10 A
100 A
140 A
12 V / 3 mA
10
0.1 W
10 millions operating cycles
3600 cycles/h
1200 cycles/h
900 cycles/h
UL 508, CSA C22.2 N°14
600 V
600 V AC, 600 V DC
A600, Q600
10 A
7200 VA
720 VA
2.5 A
69 VA
(delivered in open position, screws of unused terminals must be tightened)
M3.5
1 ... 2.5 mm²
1 ... 2.5 mm²
0.75 ... 2.5 mm²
0.75 ... 2.5 mm²
0.75 ... 2.5 mm²
0.75 ... 1.5 mm²
8 mm
AWG 18 ... 14
10 mm
IP20
Flat Ø5.5 / Pozidriv 2
1.2 Nm / 11 lb.in
-7
e
e
AC-15 acc. to IEC 60947-5-1
AC-15 acc. to IEC 60947-5-1
Catalogue Page
1SBC 101 136 S0201
ABB | 13