C321KM60B EATON CUTLER HAMMER, C321KM60B Datasheet

no-image

C321KM60B

Manufacturer Part Number
C321KM60B
Description
Mechanical Interlock Kit
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of C321KM60B

Continuous Load Current
75A
October 2008
CA08102001E
Contents
Description
Product Family Overview
Contactors
Starters
NEMA Type 1 Enclosed Control
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35-29
Renewal Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35-32
Technical Data and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35-35
Contactors — Heavy-Duty Special Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . 35-36
Contactors — Direct Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35-39
For more information visit: www.eaton.com
Application Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35-2
Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35-2
20 – 40A, Compact 1- and 2-Pole — C25 . . . . . . . . . . . . . . . . . . . . . . . . . . 35-3
15 – 360A, 2-, 3- and 4-Pole — C25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35-5
15 – 360A, Options and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35-7
15 – 40A, 3-Pole Fuse Block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35-9
15 – 75A, Reversing and 2-Speed — C65 . . . . . . . . . . . . . . . . . . . . . . . . . . 35-10
25 – 60A, Single and Three-Phase — A25, B25 . . . . . . . . . . . . . . . . . . . . . 35-11
Overload Relay and Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35-13
Heater Packs — Class 10 and Class 20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35-14
15 – 45A, Single and Three-Phase — A27, B27 . . . . . . . . . . . . . . . . . . . . . 35-15
Overload Relay Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35-18
15 – 75A, Single and Three-Phase — A29, B29 . . . . . . . . . . . . . . . . . . . . . 35-20
15 – 60A Contactors — C25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35-26
25 – 60A Starters — A25, B25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35-27
15 – 45A Starters — A27, B27 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35-28
Definite Purpose Contactors & Starters
Definite Purpose Contactors & Starters
Page
35-1
35

Related parts for C321KM60B

C321KM60B Summary of contents

Page 1

... Starters — A27, B27 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35-28 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35-29 Renewal Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35-32 Technical Data and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35-35 Contactors — Heavy-Duty Special Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . 35-36 Contactors — Direct Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35-39 Definite Purpose Contactors & Starters For more information visit: www.eaton.com 35-1 Page ...

Page 2

... C = Common Control Wiring S = Separate Control Wiring Enclosure Type N = Open with Metal Mounting Plate R = Open with DIN Rail Mounting Adapter (2- and 3-Pole, 15 – 50A Contactors Only NEMA Type 1 Enclosed Power Terminals A = Binding Head Screw B = Binding Head Screw and Quick Connect Terminals (side by side) ...

Page 3

... Standard Power Terminals — 5/16" Hex Washer Head Screws Quad (4) Quick Connect Terminals on all Line and Load Terminals Box Lugs available as option Contactors are marked with Line and Load Terminal Designations Operating Temperature Range: -13 to 158°F (-25 to 70°C) Terminal Wire Range — ...

Page 4

... When Ordering Specify Catalog Number plus Magnet Coil Suffix Modify Catalog Number for any options required — see factory installed Options Page 35-3 Table 35-5. Compact Contactors Product Selection— Open Type Ampere Ratings Inductive Resistive Locked Rotor Full Load 240 – ...

Page 5

... Box lugs — 15 – 50A: – posidrive screw or 5/32 hex socket screw – Upper Level: 14 – 4 AWG (one conductor) – Lower Level: 14 – 6 AWG (one conductor) Table 35-8. IEC/CE Ratings (IEC 60947-4-1, EN 60947-4-1) for 15A through 50A C25D_Contactors C25D_ AC-1 (Ic) AC-3 (Ie) Inductive 480V 600V ...

Page 6

... Definite Purpose Contactors & Starters 35-6 Contactors 15 – 360A, 2-, 3- and 4-Pole — C25 Product Selection When Ordering Specify Catalog Number plus Magnet Coil Suffix, below Table 35-12. C25 Contactors Product Selection— Open Type Rating, Amperes 35 Inductive Resistive Line Locked Full Load ...

Page 7

... October 2008 Options — Factory Installed To order C25, C65, A25 and B25 Contactors and Starters with the factory installed options listed below, change the basic Catalog Number listed in the Product Selection Table as noted. Table 35-14. Factory Installed Options Description Code Number of ...

Page 8

... Interlock Table 35-20. Mechanical Interlock Kit for 15 through 75A Catalog Price Number U.S. $ C321KM60B Solid-State ON DELAY Timer Adder U.S. $ Side Mounted on C25D, C25E and C25F Frame This timer is designed to be wired in series with the load (typically a coil). When the START button is pushed (power applied to timer), the ON DELAY timing function starts ...

Page 9

... B C Side View Figure 35-2. 3-Pole Fuse Block and Contactor Dimensions CA08102001E Definite Purpose Contactors & Starters Contactors 15 – 40A, 3-Pole Fuse Block To order factory assembled, add Suffix Number from table below to Catalog Number of contactor listed on Page 35-6 and make necessary price addition ...

Page 10

... Auxiliary Contacts on either side — order factory assembled or as kits for field installation. See Page 35-7. Product Selection Table 35-26. Reversing and 2-Speed Contactors Product Selection — Open Type — Unwired, Mechanically Interlocked Only Rating, Amperes Inductive Resistive Line ...

Page 11

... C25 Definite Purpose Contactors and Freedom Series Bi- metallic Ambient Compensated Over- load Relays mounted on a common mounting plate. A25 Starter CA08102001E Definite Purpose Contactors & Starters Starters 25 – 60A, Single and Three-Phase — A25, B25 Features Overload Relay Selectable Manual or Automatic Reset operation Interchangeable Heater Packs adjustable ± ...

Page 12

... Definite Purpose Contactors & Starters 35-12 Starters 25 – 60A, Single and Three-Phase — A25, B25 Product Selection When Ordering Specify Catalog Number plus Magnet Coil Suffix Heater Packs for specific FLA of motor, see Page 35-14 35 Table 35-33. Single- and Three-Phase Starters Product Selection— Open Type Ampere Rating Max ...

Page 13

... To test overload relay for trip indication when in manual reset, pull out the blue RESET button. An orange flag will appear indicating that the device has tripped. Push RESET button in to reset. CA08102001E Definite Purpose Contactors & Starters Starters Overload Relay and Accessories 1.0 Service ...

Page 14

... Definite Purpose Contactors & Starters 35-14 Starters Heater Packs — Class 10 and Class 20 Heater Packs Fast Trip — Class 10 Heater Packs Manual or Automatic Reset Note: Heater packs are shipped carton. Catalog Numbers listed below are for 3 heater packs. Table 35-38. Fast Trip Ratings ...

Page 15

... C25 Definite Purpose Contactors and XT Series Bi-metallic Ambient Compensated Overload Relays. A27 Starter CA08102001E Definite Purpose Contactors & Starters Starters 15 – 45A, Single and Three-Phase — A27, B27 Features Selectable Manual or Automatic Reset operation Class 10 Trip Class Bimetallic, ambient compensated operated ...

Page 16

... Definite Purpose Contactors & Starters 35-16 Starters 15 – 45A, Single and Three-Phase — A27, B27 Product Selection When Ordering Specify Catalog Number plus Magnet Coil Suffix plus Overload Relay Suffix (see example at right) 35 Table 35-43. Three-Phase Starter Product Selection — Open Type ...

Page 17

... Starters with DC coils include an early breaking auxiliary contact, C320KGD1. See Page 35-34 for more detail. Available through 45A. Class H AC Coils available as option. Add 2 before AC Coil Suffix letter. CA08102001E Definite Purpose Contactors & Starters Starters 15 – 45A, Single and Three-Phase — A27, B27 Max. Common Control ...

Page 18

... Definite Purpose Contactors & Starters 35-18 Starters Overload Relay Specifications Overload Relays These tripping characteristics are the mean values of the spread at 20°C ambient temperature in a cold state. 35 Table 35-49. Overload Relay — Technical Data and Specifications Description General Standards Climatic Proofi ...

Page 19

... CA08102001E Definite Purpose Contactors & Starters Starters Overload Relay Specifications XTOB…CC1 6000 III (0.75 – (0.75 – 2. (18 – 12) M3.5 0.8 – 1.3 7 – 11.5 ...

Page 20

... Cutler-Hammer A29 and B29 Definite Purpose Starters from Eaton’s electrical business combine the features and flexibility of the C25 Definite Purpose Contactors and C396 Electronic Over- load Relays. Features Page Standard Version: Selectable Trip Class (5, 10, 20, 30) with Selectable Manual or Auto Reset (45 and ...

Page 21

... Control C = Common Control S = Separate Control Enclosure Type N = Open with Metal Mounting Plate R = Open with DIN Rail Mounting Adapter (2- and 3-Pole, 15 – 50A Contactors Only NEMA Type 1 Enclosed Power Terminals 15 – 40A Contactor A = Binding Head Screws without Quick Connect Terminals B = Binding Head Screws with Quick Connect ...

Page 22

... Definite Purpose Contactors & Starters 35-22 Starters 15 – 75A, Single and Three-Phase — A29, B29 Product Selection When Ordering Specify Catalog Number plus AC Coil Code, Auxiliary Contact Code, OLR Model Designation and Overload Range Code (see Table 35-52) Table 35-52. Catalog Numbering System ...

Page 23

... Incomplete Catalog Number. Replace underscore (_) with Suffix (see Table 35-54). CA08102001E Definite Purpose Contactors & Starters Starters 15 – 75A, Single and Three-Phase — A29, B29 DP Starters with C396 Electronic Overload 15A, 25A and 30A Contactor P50 = 0.1 – 0.5A 002 = 0.4 – ...

Page 24

... Definite Purpose Contactors & Starters 35-24 Starters Overload Relay Specifications Technical Data and Specifications Table 35-56. Overload Relay Specifications General C396_2_ Description Standard Protection Thermal 1.05 x FLA: Does not trip 1.25 x FLA: Overload trip Phase Loss 1 Phase = 0, Trip time = 3s (Hot Status) ...

Page 25

... C396A2A008SELDE 6.4 – 32 15, 25, 30, 40, 50 C396A2A032SELDF 9 – 45 40, 50 C396A2A045SELDF 65 mm Overload Frame Size 15 – 75 60, 75 C396B2A075SELDG Discount Symbol 1CD-5C. CA08102001E Definite Purpose Contactors & Starters Starters Stand-Alone Overload Relay Price U.S. $ For more information visit: www.eaton.com 35-25 Discount Symbol . . . . . . . . . . . . . . . . . . . . . . 1CD-5C 35 ...

Page 26

... Definite Purpose Contactors & Starters 35-26 NEMA Type 1 Enclosed Control 15 – 60A Contactors — C25 35 NEMA 1 Enclosed DP Contactor Table 35-59. 2-, 3- and 4-Pole NEMA Type 1 Enclosed Contactors Product Selection Rating, Amperes Inductive Resistive Line Full Load per Pole Voltage 15 20 115 ...

Page 27

... Cutler-Hammer A25 and B25 Definite Purpose Starters from Eaton’s electrical business combine the features and flexibility of the C25 Definite Purpose Contactors and Freedom Series Bi- metallic Ambient Compensated Over- load Relays mounted on a common mounting plate. Standards and Certifications UL Recognized Components UL File #E-1491, Guide NLDX2 CSA Certifi ...

Page 28

... Definite Purpose Contactors & Starters 35-28 NEMA Type 1 Enclosed Control 15 – 45A Starters — A27, B27 35 NEMA 1 Enclosed DP Starter Table 35-65. Single- and Three-Phase NEMA Type 1 Enclosed Starters Product Selection Ampere Rating Max. Motor hp Inductive Line Locked 1-Phase Full Load Voltage ...

Page 29

... Mtg. for #10-32 Screw 25 and 30 Ampere Open Type Figure 35-10. Approximate Dimensions — Open Type 25, 30, 40, 50 and 60 Ampere NEMA 1 Enclosed Figure 35-11. NEMA 1 Enclosed Dimensions CA08102001E Definite Purpose Contactors & Starters Dimensions Ship. Wt. Lbs. (kg) Mounting Auxiliary Contact Adder 6.55 .20 .54 1 ...

Page 30

... Definite Purpose Contactors & Starters 35-30 Dimensions A27 and B27 Starters Table 35-69. Approximate Dimensions and Shipping Weights Ampere Dimensions in Inches (mm) Size Wide High A B Open Type 15 and 25 2.40 5.50 35 (Metal Plate) (61.0) (139.0) 15 and 25 2.23 5.20 (DIN Rail Mount) (56.5) (133 ...

Page 31

... NEMA 1 Enclosed 15 – and 3 4.10 (104.0) 6.75 (171.0) 25 – 5.62 (142.0) 9.51 (241. and 3 Add 0.30 inch (8 mm) to width for C25 contactors with DC coils. 15–50 Ampere, 2- and 3-Pole (C799B18 Figure 35-14. Enclosures Mtg. Holes/Slots for 8 Screws 15–75 Ampere (Non-reversing) ...

Page 32

... Table 35-71. Renewal Contact Kits for C25 Definite Purpose Contactors Catalog 1-Pole Kit Price Number Part No. U.S. $ C25FNF250 — C25FNF350 — C25FNF260 — C25FNF360 — C25FNF275 — ...

Page 33

... CA08102001E Definite Purpose Contactors & Starters Renewal Parts Sealed (Maximum) Coil Suffix Watts VA Watts 73.6 7.71 2.80 R 70.7 7.58 2.79 T 73.3 7 ...

Page 34

... A1 (Top) Hold (Seal) NCI Early Break Normally Closed Auxiliary Contact Figure 35-16. DC Coil Elementary Diagram — Contactors and Starters Max. Max. Sealed Sealed Amperes Watts 69 .272 3 ...

Page 35

... CA08102001E Definite Purpose Contactors & Starters Technical Data and Specifications Caution — These average ratings could be high or low for a specific motor and therefore heater coil selection on this basis always involves risk. For fully reliable motor protection, select heater coils on the basis of full load current rating as shown on the motor nameplate ...

Page 36

... Line, Load Terminal TK250A Kit Surge Suppressor SS56 Includes two terminals and hardware for # 600 kcmil Cu conductors. Contactors supplied with terminals for ring type connectors only. For more information visit: www.eaton.com Benefits All contacts are silver alloy, providing long life and resistance ...

Page 37

... N/A 1266C29G04 1254C70G07 N/A N/A 1266C29G09 N/A N/A 1254C70G12 Ship. Wt. Lbs. (kg) 16.0 (7.3) 19.0 (8. and 100 Ampere Contactors 28.0 (12.7) 50.0 (22.7) C Figure 35-17. Contactor Dimensions For more information visit: www.eaton.com 35-37 Model A — 250A Model B — 250A 2-, 3-Pole Price 2-, 3-Pole Price U ...

Page 38

... For other coil voltages, refer to replacement coils on Page 35-37 and insert proper letter in place of 9th digit of listed Catalog Number. Example: DPCK3035WW with 380/50 coil DPCK3035HW. If short load terminals are desired, add the letter S in the 10th position of the listed Catalog Number. Example: DPCK3250WS. Table 35-81. Catalog Number DPCK Air Break Contactors — 4- and 5-Pole Open Ampere Rating 600V ...

Page 39

... October 2008 Contents Description Page DC Definite Purpose Contactors Mill Type Contactors . . . . . 35-39 600V Contactors . . . . . . . . 35-41 DPM 1000V Contactor . . . . 35-46 AVD-Contactor . . . . . . . . . . 35-48 D-Contactor . . . . . . . . . . . . 35-50 Reversing/Assignment Contactor . . . . . . . . . . . . . 35-52 Mill Type Contactors Cat. No. C80DG12 Size 2 — 2-Pole Contactor CA08102001E Definite Purpose Contactors & Starters Contactors — ...

Page 40

... Configuration Coil Voltage See Tables 35-84 and 35-85 on Page 35-39 for Options. Product Selection When Ordering Specify The Catalog Number with any required Accessories Table 35-87. DC Mill Type Contactors Product Selection NEMA Open Type Contactors Size Number of Blowout Coil 230V Coil ...

Page 41

... With two interlocks mounted. CA08102001E Definite Purpose Contactors & Starters Contactors — Direct Current 600V Contactors Product Description These DC Contactors are designed to handle rugged DC applications. They provide durable service and easy installation and maintenance. Application Description Applications including Mining, Milling, Cranes and Transportation. ...

Page 42

... Definite Purpose Contactors & Starters 35-42 Contactors — Direct Current 600V Contactors — Dimensions Table 35-92. Rear Connector Kit for ME Contactors Catalog Price Number U.S. $ 2184A10G08 Field installation only. Table 35-94. Mechanical Interlocks, Unmounted Type Contactor 35 Type Size M-25 ME All M-25 ...

Page 43

... Price U.S. $ 115V N/A 230V L482211G01 550V N/A 2 coils connected in series. 2 coils connected in parallel. CA08102001E Definite Purpose Contactors & Starters Contactors — Direct Current 600V Contactors — Renewal Parts MD 510 Coil Part No. 45A5515G11 M & MD 510 Sym Part Price Sym Wiring Number U ...

Page 44

... Definite Purpose Contactors & Starters 35-44 Contactors — Direct Current 600V Contactors — Renewal Parts ME Series Table 35-97. Kits Description 1 NO Pole Qty. Part Number Contact Kit 1 2184A10G14 Arc Box 10/25/50A 1 2184A10G09 Arc Box 100/150A 1 2184A10G10 Shunt Kit 1 2184A10G21 35 Armature Kit ...

Page 45

... Other coil voltages available, see Table 35-91 on Page 35-41. Substitute Suffix Code of desired voltage for last digit in listed Catalog Number. Example: ME010B. For 10 – 150A rear connected contactors, order front connected ME contactor above and rear connection kit, Catalog Number 2184A10G08, (field installed only). See Table 35-92 on Page 35-42. ...

Page 46

... Definite Purpose Contactors & Starters 35-46 Contactors — Direct Current DPM 1000V Contactor DPM 1000V Contactor 35 Cat. No. 2120A07G02 DC Contactor Product Description The DPM 1000V DC Definite Purpose Contactor has been designed to meet severe environmental and vibration conditions found in your worst appli- cations ...

Page 47

... Dimensions in Inches (mm) Ship. Wt. Lbs. (kg) Width Height Depth 4.13 (105) 11.06 12.12 30.5 (13.8) (280.9) (307.8) CA08102001E Definite Purpose Contactors & Starters Contactors — Direct Current DPM 1000V Contactor Weight = 30.5 lbs. (13.8 kg) Clearance to Ground 6.25 (158.8) 12.13 1.38 (308.0) (34.9) 1.00 (25.4) .50 (12 ...

Page 48

... Definite Purpose Contactors & Starters 35-48 Contactors — Direct Current AVD-Contactor AVD-Contactor 35 2000V Contactor Product Description The AVD-Contactor is a single-pole normally open, load break, bi-directional definite purpose DC contactor. The device is rated at 1400 amps continu- ous and is capable of switching up to 2000V DC loads. ...

Page 49

... Note: Please consult our Technical Resource Center for Catalog Numbers of other device configurations and application assistance. CA08102001E Definite Purpose Contactors & Starters Contactors — Direct Current AVD-Contactor 15.00 (381) 1.25 Max Maximum Stud Length to Maintain 2000 Volt (Top Right Stud Only) Table 35-112 ...

Page 50

... Definite Purpose Contactors & Starters 35-50 Contactors — Direct Current D-Contactor D-Contactor 35 750V Contactor Product Description The D-Contactor is a single-pole nor- mally open, load break, bi-directional definite purpose DC contactor. Two devices are available rated at 1800A and 3000A at 750V DC. Application Description The D-Contactor was designed for the ...

Page 51

... DC 2NO/2NC 100V DC 3NO/1NC 115V DC Note: Please consult our Technical Resource Center for Catalog Numbers of other device configurations and application assistance. CA08102001E Definite Purpose Contactors & Starters Contactors — Direct Current D-Contactor 1.75 (44.5) to Remove Arc Shoot 6.52 (165.6) 9.6 (243 ...

Page 52

... DC drives for DC motor revers- ing and drive assignment applications. Features Bi-directional current carrying capability (non-load break) Can replace four single-pole contactors in DC motor reversing applications Can replace two or four single-pole contactors in DC motor assignment applications Any combination eight isolated auxiliary contacts ...

Page 53

... Holes 3.89 (31.8) (98.8) Shipping Weight 45 Lbs. (20.4 kg) Figure 35-22. Reversing Contactor Approximate Dimensions in Inches (mm) and Shipping Weight Product Selection Table 35-125. Reversing/Assignment Contactors (3-Position, Center OFF) Device Type Auxiliary Contact Configuration Reverser 8NO 4NO/4NC Assignment 4NO/4NC Note: Please consult our Technical Resource Center for Catalog Numbers of other device confi ...

Page 54

... Definite Purpose Contactors & Starters 35-54 35 For more information visit: www.eaton.com October 2008 CA08102001E ...