V23130C2421A431 Tyco Electronics, V23130C2421A431 Datasheet

no-image

V23130C2421A431

Manufacturer Part Number
V23130C2421A431
Description
RELAY, BATTERY DISCONNECT, 24V
Manufacturer
Tyco Electronics
Datasheet

Specifications of V23130C2421A431

Coil Voltage Vdc Nom
24V
Contact Current Max
190A
Contact Voltage Dc Nom
24V
Coil Resistance
19.9ohm
Relay Mounting
Panel
External Width
86mm
External Depth
83mm
Contact Configuration
SPST
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
– Limiting continuous
– Electrically settable and
– Suitable for voltage levels
– High peak current carrying
Typical Applications
– Preheating systems
– Battery disconnection to
– Dual battery applications
– Energy-management
– Keeps the power net in
– Seasonal, service and
Please contact Tyco Electronics
for relay application support.
Disclaimer
All technical performance data apply to the relay as such, specific conditions of the individual application are not considered. Please always check the suitability of the
relay for your intended purpose. We do not assume any responsibility or liability for not complying herewith. We recommend to complete our questionnaire and to request
our technical service. Any responsibility for the application of the product remains with the customer only. All specifications are subject to change without notification.
All rights of Tyco Electronics are reserved.
current 190 A at 85°C
resettable ON/OFF bistable
device
up to 42 V
capability up to 1500 A
(e.g. for diesel engines,
catalytic converters)
prevent fire caused by
short circuits during an
accident
provide the start reliability
by a separate starter battery
balance and to control and
secure the health of the
energy storage systems
transport deactivation
High Current Solutions
High Current Devices
Battery Disconnect Switch BDS-A
Design
– ELV/RoHS/WEEE compliant
– Dustproof; protection class IP54
– Weatherproof protection
Weight
Approx. 210 g (7.41 oz.)
Nominal Voltage
12 V or 24 V
All specifications subject to change. Consult Tyco Electronics for latest specifications.
to IEC 529 (EN 60 529)
Terminals
– Quick connect terminals (coil)
– Screw terminals (load)
Conditions
All parametric, environmental and
endurance tests are performed
according to EIA Standard RS-407-A
at standard test conditions unless
otherwise noted:
23°C ambient temperature,
20 - 50% RH, 998.9 ±33.9 hPa.
For general storage and processing
recommendations please refer to our
Application Notes and especially to
Storage in the “Glossary” page 23 or
at http://relays.tycoelectronics.com/
appnotes/
Catalog 1308028-2
Revised 3-2008
130-C_3D2
199

Related parts for V23130C2421A431

V23130C2421A431 Summary of contents

Page 1

... We do not assume any responsibility or liability for not complying herewith. We recommend to complete our questionnaire and to request our technical service. Any responsibility for the application of the product remains with the customer only. All specifications are subject to change without notification. All rights of Tyco Electronics are reserved. All specifications subject to change. Consult Tyco Electronics for latest specifications. Terminals Conditions – ...

Page 2

... High Current Solutions High Current Devices Battery Disconnect Switch BDS-A Dimensional Drawing 200 All specifications subject to change. Consult Tyco Electronics for latest specifications. Catalog 1308028-2 Revised 3-2008 130C_DD_3 ...

Page 3

... Values are influenced by system temperature and load current. For further details please consult our Technical Application Engineers. 2) Equivalent average sound pressure level leq, switch cycled with 1 Hz, microphone distance 10 cm, measuring time 15 s. All specifications subject to change. Consult Tyco Electronics for latest specifications. 23°C 85°C 125° ...

Page 4

... Standard Delivery Packs (orders in multiples of delivery pack) BDS-A: 24 pieces 202 All specifications subject to change. Consult Tyco Electronics for latest specifications. Refer to Storage in the “Glossary” catalog page 23 or http://relays.tycoelectronics.com/appnotes/ Testing as per IEC 68-2-6 (sine sweep) IEC 68-2-27 EN 60529 (IEC 529) ...

Related keywords