K8ABPW2 Omron, K8ABPW2 Datasheet - Page 3

RELAY, VOLTAGE, 3P, 220-480V

K8ABPW2

Manufacturer Part Number
K8ABPW2
Description
RELAY, VOLTAGE, 3P, 220-480V
Manufacturer
Omron
Series
K8ABr
Datasheet

Specifications of K8ABPW2

Contact Configuration
SPDT
Supply Voltage Max
480VAC
Relay Mounting
DIN Rail
Control Voltage Type
AC
Svhc
No SVHC (15-Dec-2010)
Contact Current Ac Max
6A
Contact Voltage Ac Max
250V
■ Specifications
Cat. No. N148-E1-01
Ambient operating temperature
Storage temperature
Ambient operating humidity
Storage humidity
Altitude
Voltage fluctuation range
Input frequency
Output relays
Terminal screw tightening torque
Crimp terminals
Insulation resistance
Degree of protection
Case color
Case material
Weight
Mounting
Dimensions
Installation environment
Application standards
Safety standards
EMC
Resistive load
Inductive load
Minimum load
Maximum contact voltage 250 VAC
Maximum contact current 6 A AC
Maximum switching
capacity
Mechanical life
Electrical life
− 20 to 60°C (with no condensation or icing)
− 40 to 70°C (with no condensation or icing)
25% to 85%
25% to 85%
2,000 m max.
85% to 110% of rated input voltage
50/60 Hz ±5 Hz (AC power supply)
6 A at 250 VAC (cos φ = 1)
6 A at 30 VDC (L/R = 0 ms)
1 A at 250 VAC (cos φ = 0.4)
1 A at 30 VDC (L/R = 7 ms)
10 mA at 5 VDC
1,500 VA
10,000,000 operations
Make: 50,000 times, Break: 30,000 times
1.2 N·m
Two solid wires of 2.5 mm
tightened together
20 M Ω (at 500 V) between charged terminals and exposed uncharged parts
20 M Ω (at 500 V) between any charged terminals (i.e., between input, output, and power
supply terminals)
Terminal section: IP20, Rear case: IP40
Munsell 5Y8/1 (ivory)
ABS resin (self-extinguishing resin) UL94-V0
200 g
Mounted to DIN Track or via M4 screws
22.5 (W) x 90 (H) x 100 (D) mm
Overvoltage Category III, Pollution Degree 2
EN60255-5/-6
EN60664-1
EMI: EN61326 Industrial applications
Electromagnetic interference wave
Terminal interference wave voltage
EMS: EN61326 Industrial applications
Electrostatic discharge EN61000-4-2: 8 kV (in air)
Radiating radio-frequency electromagnetic field EN61000-4-3:
Burst EN61000-4-4:
Surge EN61000-4-5:
Conducted RF EN61000-4-6:
Power frequency magnetic field immunity
EN61000-4-8: 30 A/m
Voltage dip/short interruptions
EN61000-4-11: 0.5 cycle, 0.180° each, polarity 100% (rated voltage)
CISPR11 Group 1, Class A: CISPR16-1/-2
CISPR11 Group 1, Class A: CISPR16-1/-2
10 V/m 1 kHz sine wave amplitude modulation (80 MHz to 1 GHz)
Three-phase Voltage Relay
2
, two crimp terminals of 1.5 mm
1 kV (I/O signal line), 2 kV (power line)
1 kV with line (power line),
2 kV with ground (power line)
3 V (0.15 to 80 MHz)
K8AB-PW
2
with insulation sleeves, can be
3

Related parts for K8ABPW2