G2RL-24DC24 Omron, G2RL-24DC24 Datasheet - Page 3

POWER RELAY, DPDT, 24VDC, 8A, PC BOARD

G2RL-24DC24

Manufacturer Part Number
G2RL-24DC24
Description
POWER RELAY, DPDT, 24VDC, 8A, PC BOARD
Manufacturer
Omron
Datasheet

Specifications of G2RL-24DC24

Relay Type
General Purpose
Coil Voltage Vdc Nom
24V
Contact Current Max
8A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Coil Resistance
1440ohm
Contact Configuration
DPDT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
■ Approved Standards
UL Recognized (File No. E41643) / CSA Certified (File No. LR31928) - - Ambient Temp. = 40°C
Note: Consult Omron for additional UL / CSA ratings
VDE (EN61810-1) (License No. 119650)
Note: To achieve approved life cycles on sealed models, the relay should be vented by removing the “knock off vent nib” on top of relay case after
Electrical Life Data
Note: 1. The results shown reflect values measured using very severe test conditions i.e., Duty: 1 s ON/1 s OFF.
G2RL-1A
G2RL-1
G2RL-1A-E
G2RL-1-E
G2RL-1A-H
G2RL-1-H
G2RL-2A
G2RL-2
G2RL-1(A)
G2RL-1(A)-E
G2RL-1(A)-H
G2RL-2(A)
G2RL-1-E
G2RL-1
G2RL-1-H
G2RL-2
the soldering/washing process.
2. In order to obtain the full rated life cycles on the fully sealed models, the relay should be properly vented by removing the “knock off vent
3. Electrical endurance will vary depending on the test conditions. Contact your OMRON representative if you require more detailed
nib” on top of the relay case after the soldering/washing process.
information for the electrical endurance under your test conditions.
Model
Model
1 pole
1 pole
1 pole
2 poles
SPST-NO
SPDT
SPST-NO
SPDT
SPST-NO
SPDT
DPST-NO
DPDT
Contact form
16 A at 250 VAC (cosφ=1)
16 A at 24 VDC
8 A at 250 VAC (cosφ=0.4)
8 A at 30 VDC (L/R=7 ms)
12 A at 250 VAC (cosφ=1)
12 A at 24 VDC
5 A at 250 VAC (cosφ=0.4)
5 A at 30 VDC (L/R=7 ms)
10 A at 250 VAC (cosφ=1)
10 A at 24 VDC
8 A at 250 VAC (cosφ=1)
8 A at 30 VDC
Contact form
3 to 48 VDC
3 to 48 VDC
5 to 24 VDC
3 to 48 VDC
Coil ratings
5, 12, 18, 22, 24, 48 VDC
5, 12, 18, 22, 24, 48 VDC
5, 9, 12, 24 VDC
5, 12, 18, 22, 24, 48 VDC
30,000 operations min.
30,000 operations min.
200,000 operation min. (normally open side operation)
10,000 operation min. (normally open side operation)
50,000 operations min.
30,000 operations min.
150,000 operation min. (normally open side operation)
20,000 operation min. (normally open side operation)
100,000 operations min.
50,000 operations min.
30,000 operations min.
30,000 operations min.
12 A at 250 VAC (General use)
12 A at 24 VDC (Resistive)
16 A at 250 VAC (General use)
16 A at 24 VDC (Resistive)
10 A at 250 VAC (General use)
10 A at 24 VDC (Resistive)
8 A at 277 VAC (General use)
8 A at 30 VDC (Resistive)
Coil ratings
Contact ratings
12 A at 250 VAC (cosφ=1)
12 A at 24 VDC (L/R=0 ms)
AC15: 3 A at 240 VAC
DC13: 2.5 A at 24 VDC, 50 ms
16 A at 250 VAC (cosφ=1)
16 A at 24 VDC (L/R=0 ms)
AC15:
DC13:
10 A at 250 VAC (cosφ=1)
10 A at 24 VDC (L/R=0 ms)
8 A at 250 VAC (cosφ=1)
8 A at 24 VDC (L/R=0 ms)
AC15:
DC13:
PCB Relay
100,000
50,000
100,000
50,000
50,000
100,000
3 A at 240 VAC (NO)
1.5 A at 240 VAC (NC)
2.5 A at 24 VDC (NO), 50 ms
1.5 A at 240 VAC
2 A at 30 VDC, 50 ms
Number of test operations
Contact ratings
G2RL
205

Related parts for G2RL-24DC24