G2RV-SL500-DC12DC11 Omron, G2RV-SL500-DC12DC11 Datasheet - Page 3

POWER RELAY, SPDT, 12VDC, 6A, PLUG IN

G2RV-SL500-DC12DC11

Manufacturer Part Number
G2RV-SL500-DC12DC11
Description
POWER RELAY, SPDT, 12VDC, 6A, PLUG IN
Manufacturer
Omron
Datasheet

Specifications of G2RV-SL500-DC12DC11

Relay Type
General Purpose
Coil Voltage Vdc Nom
12V
Contact Current Max
6A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Contact Configuration
SPDT
Coil Type
DC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
■ Characteristics
Note: Data shown are of initial values.
Switching Timing
■ Approved Standards
UL 508 (File No. E41643)
IEC/VDE (EN 61810)
Contact resistance
Operate (set) time
Release time
Max. operating frequency
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Life expectancy
Ambient temperature
Ambient humidity
Weight
Overvoltage category
Pollution degree
G2RV-SL7❏❏/5❏❏ DC12
G2RV-SL7❏❏/5❏❏ DC24
G2RV-SL7❏❏/5❏❏ AC/DC24
G2RV-SL7❏❏/5❏❏ AC/DC48
G2RV-SL7❏❏/5❏❏ AC110
G2RV-SL7❏❏/5❏❏ AC230
G2RV-SL Series
1 pole
Contact form
Model
Model number
Item
SPDT
12, 24 VDC
24, 48 VAC/DC
110, 230 VAC
Contact form
Coil ratings
100 mΩ max.
20 ms max.
40 ms max.
Mechanical: 18,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
1,000 MΩ min. (at 500 VDC)
4,000 VAC, 50/60 Hz for 1 min between coil and contacts
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
Destruction: 10 to 55 Hz, 1.0 mm double amplitude
Malfunction: 10 to 55 Hz, 1.0 mm double amplitude
Destruction: 1,000 m/s
Malfunction: 100 m/s
Mechanical: 5,000,000 operations min.
Electrical: 100,000 typical;
NO 70,000 operations min.;
NC 50,000 operations min.
Operating: –40°C to 55°C (with no icing or condensation)
Operating: 5% to 85%
Approx. 35 g
III
2
12 to 48 VDC
24 to 230 VAC
250 VAC 6 A (Res.)
30 VDC 6 A (Res.)
400 VAC 2 A (Res.)
2
Contact ratings
Operating time (typical)
(approx. 10G)
2
Coil ratings
(approx. 100G)
12 ~ 15 ms
12 ~ 15 ms
5 ~ 7 ms
5 ~ 7 ms
5 ~ 7 ms
5 ~ 7 ms
250 VAC 6 A (Resistive Load)
30 VDC 6 A (Resistive Load)
400 VAC 2 A (Resistive Load)
50,000
50,000
6,000
1 pole
Contact ratings
Operations
Slim Relay
Release time (typical
22 ~ 30 ms
22 ~ 30 ms
22 ~ 30 ms
17 ~ 22ms
5 ~ 8 ms
5 ~ 8 ms
G2RV
6,000
Operations
3

Related parts for G2RV-SL500-DC12DC11