W389CX-8 Magnecraft / Schneider Electric, W389CX-8 Datasheet - Page 56

POWER RELAY, DPDT, 24VDC, 25A, FLANGE

W389CX-8

Manufacturer Part Number
W389CX-8
Description
POWER RELAY, DPDT, 24VDC, 25A, FLANGE
Manufacturer
Magnecraft / Schneider Electric
Series
W389r
Datasheet

Specifications of W389CX-8

Relay Type
General Purpose
Coil Voltage Vdc Nom
24V
Contact Current Max
25A
Contact Voltage Ac Nom
300V
Contact Voltage Dc Nom
28V
Coil Resistance
400ohm
Contact Configuration
DPDT
Coil Type
DC
Rohs Compliant
No
Contact Form
DPDT
Coil Voltage
8 V
Contact Rating
25 A
Mounting Style
Flange
Contact Material
Gold Flashed Silver
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
W389CX-8
Manufacturer:
MAGLAYERS
Quantity:
20 000
1...
CLASS
GENERAL
COIL
CONTACTS
DIELECTRIC STRENGTH
TEMPERATURE
LIFE EXPECTANCY
MISCELLANEOUS
GENERAL
HORSEPOWER RATING:
BENEFITS OF RECTIFIED COIL DESIGN:
CURRENT RATING:
1. Chatter Free Operation in Brownout Conditions Down to 85 VAC and Will not Overheat up to 140 VAC.
2. Less Power Consumption and Less Heating.
B E N E F I T S
ELECTRICAL LIFE
@ RATED LOAD:
55
Across Open Contacts:
Pull-in Voltage:
Dropout Voltage:
Coil Insulation:
Nominal Power:
Contact Material:
Contact Rating:
Contact to Coil:
Contact to Frame:
Operating:
Storage:
Electrical:
Mechanical:
Enclosure:
Operating Position:
Weight:
LOAD RATING:
TUNGSTEN
DIMENSIONS SHOWN IN INCHES & (MILLIMETERS)
21
OUTLINE DIMENSIONS
2.84 MAX.
( 7 2 . 2 )
3.90 MAX.
( 9 9 . 2 )
SPECIFICA
SPECIFICA
30 AMPS @ 120/240 VAC, 20 AMPS @ 28 VDC 15 AMPS @ 120 VAC, 15 AMPS @ 28 VDC
1-1/2 HP @ 120 VAC, 2 HP @ 240 VAC
2.4 KW @ 240 VAC
200,000 OPERATIONS
PHONE: (843) 393-5778 FAX: (843) 393-4123 EMAIL: info@magnecraft.com
MAGNECRAFT:
65% of nominal voltage @ 20˚C or less for AC coils
10% of nominal voltage or more
Class “B” system (130˚C per UL standard 1446)
4.0 VA
Silver alloy
30 amps, 120/240 VAC (resistive) 25 amps, 120/240 VAC (CSA)
20 amps, 28 VDC (resistive) 1-1/2Hp, 120 VAC, 2Hp, 240 VAC
20 amps, 120 VAC (tungsten lamp)
10 amps, 240 VAC (tungsten lamp)
500 V rms
1500 V rms
1500 V rms
-40˚C to +84˚C
-40˚C to +105˚C
200,000 operations @ 20 amps tungsten, 120 VAC
5,000,000 operations @ no load
Clear polycarbonate
Vertical, contacts up or horizontal
204.7 grams approx.
.
TIONS
TIONS
W21ACPX-2
0 . 0 6 0
( 1 . 5 )
1.85 MAX.
FLASH TRANSFER POWER RELAY
( 2 5 . 4 )
( 4 6 . 9 )
1 . 0 0
1/4HP @ 120 VAC, NOT UL RATED
1 KW @ 120/240 VAC
100,000 OPERATIONS
MIDTEX:
0.437TYP.
0 . 2 5 0 T Y P.
( 11 . 0 9 )
P O L A R I Z I N G
P I N
( 6 . 3 5 )
TYPE 136
2.47 MAX.
STANDARD
AC RECTIFIED - PLUG-IN, 30 AMP
( 6 2 . 7 )
W21ACPX-2
NUMBER
PART
SWITCHES
TUNGSTEN LAMP
LOADS UP TO
20 AMPS
EXCEEDS NEMA STD. TS
D.O.T FOR:
California
Georgia
Illinois
Oregon
Maryland
North Carolina
2- 1992 APPROVED BY
MOUNTING:
FITS STANDARD
8 PIN JONES PLUG
CONFIGU-
CONTACT
RATION
DPDT
Texas
Minnesota
Colorado
Missouri
New York
UL Recognized
File No. E43641
c
COIL MEASURED
120 VAC, 50/60Hz
DPDT, 30 AMPS
MANUFACTURED UNDER
VOLTAGE
NOMINAL
WIRING DIAGRAM
INPUT
us
(VIEWED FROM PIN END)
RECTIFIED COIL
ISO 9002
7
5
3
1
168986
NOMINAL
8
6
4
2
POWER
4.0 VA
@
25˚C

Related parts for W389CX-8