62.82.8.230.0000 FINDER, 62.82.8.230.0000 Datasheet - Page 5

RELAY, DPCO, 230VAC

62.82.8.230.0000

Manufacturer Part Number
62.82.8.230.0000
Description
RELAY, DPCO, 230VAC
Manufacturer
FINDER
Datasheet

Specifications of 62.82.8.230.0000

Relay Type
Power
Coil Voltage Vac Nom
230V
Contact Current Max
30A
Contact Voltage Ac Nom
250V
Coil Resistance
7.25kohm
Coil Type
AC Coil
Coil Current
10.5mA
Nom Operating Power
2.2VA
Relay
RoHS Compliant
Contact Configuration
DPCO
Rohs Compliant
Yes
Contact specification
F 62 - Electrical life (AC) v contact current
• When switching a resistive load (DC1) having voltage and current values under the curve, an electrical life of ≥ 100·10
• In the case of DC13 loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load.
Technical data
H 62 - Maximum DC1 breaking capacity
Insulation
Insulation according to EN 61810-1 ed. 2
Insulation between coil and contacts (1.2/50 µs)
Dielectric strength between open contacts
Dielectric strength between adjacent contacts
Conducted disturbance immunity
Burst (5...50)ns, 5 kHz, on A1 - A2
Surge (1.2/50 µs) on A1 - A2 (differential mode)
Other data
Bounce time: NO/NC
Vibration resistance (5…55)Hz, max. ± 1 mm: NO/NC
Shock resistance
Power lost to the environment
Recommended distance between relays mounted on PCB
Note: the release time of the load will be increased.
Changeover contacts
10
10
10
0.2
0.1
20
10
6
4
2
1
7
6
5
20
0
1
60
4
2
Resistive load - cosϕ = 1
Inductive load - cosϕ = 0.4
100
Voltage DC (V)
3
contacts in series
8
140
insulation rated voltage
rated impulse withstand voltage
pollution degree
overvoltage category
without contact current
with rated current
12
180
220
16
(A)
H 62 - Maximum DC1 breaking capacity
Normally open contacts
0.2
0.1
V AC 1,500 (changeover contact types)
V AC 2,500 (normally open contact types)
V AC 2,500
20
10
g/g 5/3
6
mm ≥ 5
4
2
1
20
ms 3/6 (changeover)
kV 4
kV 6
W 1.3
W 3.3
V 400
g 15
62 Series - Power relays 16 A
3
III
EN 61000-4-4
EN 61000-4-5
2 pole (CO)
1
60
2
3 pole (CO)
1.3
4.3
100
Voltage DC (V)
3
contacts in series
140
level 4 (4 kV)
level 4 (4 kV)
3/— (normally open)
2 pole (NO) 3 pole (NO)
3
5
3
can be expected.
180
3
6
220
99
62

Related parts for 62.82.8.230.0000