VP2/5A/CAB/12VDC KEYSWITCH, VP2/5A/CAB/12VDC Datasheet

RELAY, PLUG-IN, DPCO, 12VDC

VP2/5A/CAB/12VDC

Manufacturer Part Number
VP2/5A/CAB/12VDC
Description
RELAY, PLUG-IN, DPCO, 12VDC
Manufacturer
KEYSWITCH
Datasheet

Specifications of VP2/5A/CAB/12VDC

Relay Type
General Purpose
Coil Voltage Vdc Nom
12V
Contact Current Max
5A
Contact Voltage Ac Nom
250V
Coil Resistance
185ohm
Coil Type
DC Coil, Bistable
Nom Operating Power
2W
Relay
RoHS Compliant
Contact Configuration
DPCO
Rohs Compliant
Yes
Clifford & S n e l l
SUMMARY OF TYPES
BASIC VP SERIES
Contacts – 2 4, 6 and 8 pole contact arrangements are available,
with a choice of contact materials to suit applications from low to
heavy duty.
Coils – Nominal coil voltages range from 6 to 200V dc, with three
types of coil to give the user a liberal choice of operating voltages.
AC Operation – For ac operation a range is available with built-in
rectifiers. See also shaded pole (long coil) VPAC Series.
Sensitive Operation – Special adjustments can be made which
provides increased sensitivity of operation, denoted by 'SEN' in the
ordering code.
Mounting – Available as a plug-in relay (also suitable for direct
wiring) or for printed circuit mounting with alternative pin layouts.
VPR SERIES
Bistable, polarised relays with either single or double wound coils,
capable of being pulsed at a minimum of ten milliseconds.
VPL SERIES
Similar to the Basic VP Series but having longer coils offering an
extended voltage range.
STANDARD CONTACT ARRANGEMENTS AND CASE SIZE – FIG. I
CONTACT TYPE
NO. OF POLES
BASIC
VP
SERIES
SEN
OPTION
VPR
SERIES
VPL
SERIES
VPAC
SERIES
M=make, B=break, C=changeover, S=standard single contact (0.2 or 1amp), TC=twin contact (0.2 or 1amp)
5A=5amp single contact, HD=heavy duty 5amp (increased pin spacing)
Shaded area gives case size and availability (confirm with sales department)
M
C
M
C
M
C
M
C
M
C
B
B
B
B
B
VP SERIES
2
1
1
1
4
4
4
2
2
2
5
5
S
6
2
2
3
2
2
3
2
2
5
5
5
5
8
3
3
3
3
VP SERIES
2
1
1
4
4
4
2
2
5
5
TC
30
6
2
2
3
2
2
5
5
This is a shaded pole version of the VPL (longer coil) series,
suitable for ac operation on 50hz supplies (other frequencies to
special order).
BRITISH TELECOM APPROVED RELAYS
These relays conform to British Telecom codes BT23 and BT32.
For BT23 the contact material is always code 'G' whilst for BT32,
code ‘F’ is used. Solderability of all relay terminals complies with
BT specification.
SOCKET AND RETAINING CLIP
Relay sockets and retaining clips (ordered separately) are
available to suit the different case sizes. Sockets are available with
printed circuit pins or solder tags.
OMISSION OF EARTH SCREW/PIN
For applications where the earthing facility is not required, the
earth screw or pin can be omitted, obviating the need to drill
printed circuit boards or panels.
EARTH CLIP
Wiring sockets are supplied complete with an earth clip (loose
piece) enabling the relay to be earthed via the fixing screw.
Miniature Cradle Relays
Keyswitch Varley VP Series miniature cradle relays offer contact, coil
and mounting options to meet many applications. They are extremely
reliable, proven through many years' manufacture and use, and are
compatible with all similar products manufactured world-wide.
Our engineers can offer invaluable advice on the choice of relay
best suited to your requirements.
VPAC SERIES
World-wide compatibility
mV/mA to 5A or 250V switching
Bistable magnetic latching types
Mounting options
BT23 and 32 approved types
Life tested to 100,000,000 mechanical operations
Comprehensive technical service
Broad custom capability
8
3
3
2
1
1
4
4
4
2
2
5
5
5A
6
2
2
3
2
2
5
5
8
3
3
Email: cliffordandsnell@aol.com
Tom Cribb Road, Thamesmead
2
2
2
5
5
Fax: +44(0)20 8317 2400
www.cliffordandsnell.com
Tel: +44(0)20 8316 4477
4
3
or (0)20 8317 1717
London SE28 0BH
HD
6
5
5
8

Related parts for VP2/5A/CAB/12VDC

VP2/5A/CAB/12VDC Summary of contents

Page 1

... Comprehensive technical service • Broad custom capability Keyswitch Varley VP Series miniature cradle relays offer contact, coil and mounting options to meet many applications. They are extremely reliable, proven through many years' manufacture and use, and are compatible with all similar products manufactured world-wide. ...

Page 2

... Volts' the sub-headings refer to the various options. i. low level or light duty single contacts twin contacts amp contacts heavy duty contacts. SEN = sensitive adjustment. The characters below these sub-headings refer to the number of poles and the contact action, i. make break changeover. COIL TYPE (Nominal voltage) Max. power at 2˚C amb Resistance (ohm) ±10% (except *±15%) Number of Turns MAXIMUM VOLTS (40˚ ...

Page 3

... Long coils (case Fig. I & 2). Coil power 2W max, 0.7W min. Frequency 50Hz Available contact combinations light duty contacts 2C, 4C twin contacts 2C, 4C 5amp contacts 2C heavy duty contacts (HD) *±15% 120 Polarity (NC closed) To change state – ...

Page 4

Tom Cribb Road, Thamesmead London SE28 0BH Tel: +44(0)20 8316 4477 or (0)20 8317 1717 Fax: +44(0)20 8317 2400 Email: cliffordandsnell@aol.com www.cliffordandsnell.com DOUBLE WOUND COILS AT 20˚C (TERMINALS 1 & 4 AND 2 & 3) Coil Type (nom.volts) 2.5 4 ...

Page 5

... Terminal numbering is identical to plug-in.Wiring relays, but with ‘staggered’ pin layout on DM & PC Socket as shown. A – hole for manual relay operation if required. B – hole required for PB relay with standard 8BA earth/mounting stud. Not required for DM Relay, PC Socket or PB Relay with LES in its code ...

Page 6

... HD CASE SIZE 1 & & COM RELAYS WITH MAKE OR BREAK CONTACTS 6-POLE MAKE OR BREAK CONTACTS (CASE SIZE CONTACT PAIRS ORDERING INFORMATION – FIG 14 Typical Relay Part No: VP Relay series VP VPR VPL VPAC Number of poles in contacts 2,4 Sensitive operation SEN = sensitive operation Mounting style ...

Related keywords