G6J-2P-Y-DC12 Omron, G6J-2P-Y-DC12 Datasheet - Page 3

SIGNAL RELAY, DPDT, 12VDC, 1A, THD

G6J-2P-Y-DC12

Manufacturer Part Number
G6J-2P-Y-DC12
Description
SIGNAL RELAY, DPDT, 12VDC, 1A, THD
Manufacturer
Omron
Series
G6JYr

Specifications of G6J-2P-Y-DC12

Contact Configuration
DPDT
Contact Current Max
1A
Contact Voltage Ac Nom
125V
Contact Voltage Dc Nom
30V
Coil Voltage Vdc Nom
12V
Coil Resistance
976.8ohm
Coil Type
DC
Coil Current
12.3mA
Contact Form
2 Form C
Coil Voltage
12 VDC
Power Consumption
140 mW
Termination Style
Solder Pin
Maximum Switching Current
1 A
Current, Rating
0.3⁄1 AAC⁄ADC
Function
General Purpose
Mounting Type
PCB
Number Of Pins
8
Power, Rating
37.5⁄30 VA⁄W
Relay Type
Electro Mechanical
Standards
UL, CSA, RoHS
Termination
Through Hole
Voltage, Control
12 VDC
Voltage, Rating
125 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
12DC G6J-2PY G6J2PY12DC,

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G6J-2P-Y-DC12
Manufacturer:
OMRON/欧姆龙
Quantity:
20 000
Part Number:
G6J-2P-Y-DC12V
Manufacturer:
OMRON
Quantity:
12 000
G6J-Y
I
Note:
Note:
Contact resistance (See note 1.)
Operating (set) time (See note 2.)
Release (reset) time (See note 2.)
Minimum set/reset signal width
Insulation resistance (See note 3.)
Dielectric
strength
Impulse
withstand
voltage
Vibration resistance
Shock resistance
Life expectancy
Failure rate (P level) (See note 4.)
Ambient temperature
Ambient humidity
Weight
Characteristics
The above values are initial values.
1. The contact resistance was measured with 10 mA at 1 VDC with a fall-of-potential method.
2. Values in parentheses are actual values.
3. The insulation resistance was measured with a 500-VDC Megger Tester applied to the same parts as those for checking the
4. This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 50 Ω . This
dielectric strength.
value may vary depending on the operating frequency, operating conditions, expected reliability level of the relay, etc. Always
double-check relay suitability under actual load conditions.
Item
Coil and contacts 1,500 VAC, 50/60 Hz for 1 min
Contacts of
different polarity
Contacts of
same polarity
Coil and contacts 2,500 VAC, 2 x 10 µ s
Contacts of
different polarity
Contacts of
same polarity
100 m Ω max.
3 ms max. (approx. 1.6 ms)
3 ms max. (approx. 1.0 ms)
---
1,000 M Ω min. (at 500 VDC)
1,000 VAC, 50/60 Hz for 1 min
750 VAC, 50/60 Hz for 1 min
1,500 VAC, 10 x 160 µ s
Destruction: 10-55-10 Hz 2.5-mm single amplitude (5-mm double amplitude)
Malfunction: 10-55-10 Hz 1.65-mm single amplitude (3.3-mm double amplitude)
Destruction: 1,000 m/s
Malfunction: 750 m/s
Mechanical: 50,000,000 operations min. (at 36,000 operations/hour)
Electrical:
10 µ A at 10 mVDC
− 40 to 85°C (with no icing or condensation)
5% to 85%
Approx. 1.0 g
G6J-2P-Y, G6J-2FS-Y, G6J-2FL-Y
Single-side Stable Relays
100,000 operations min. (with a rated load at 1,800 operations/hour)
2
(approx. 75G)
2
(approx. 100G)
3 ms max. (approx. 0.9 ms)
10 ms
G6JU-2P-Y, G6JU-2FS-Y, G6JU-2FL-Y
Single-winding Latching Relays
G6J-Y
83

Related parts for G6J-2P-Y-DC12