G6E-134P-US 5DC Omron, G6E-134P-US 5DC Datasheet - Page 3

RELAY, PCB, SPCO, 5VDC

G6E-134P-US 5DC

Manufacturer Part Number
G6E-134P-US 5DC
Description
RELAY, PCB, SPCO, 5VDC
Manufacturer
Omron
Datasheet

Specifications of G6E-134P-US 5DC

Contact Current Max
3A
Contact Voltage Ac Nom
125V
Contact Voltage Dc Nom
30V
Coil Voltage Vdc Nom
5V
Coil Resistance
125ohm
Coil Power Cont
200mW
Relay
RoHS Compliant
Coil Type
DC Coil, Monostable
Coil Current
40mA
Contact Configuration
SPDT
Rohs Compliant
Yes
Note: P level: λ 60 = 0.1 x 10
*Minimum set and reset signals width is 7 ms min.
UL508 (File No. E41515)/CSA C22.2, No.14 (File No. LR31928)
Load
Rated Load
Contact Material
Rated Carry Current
Max. switching voltage
Max. switching current
Max. switching power
Failure rate (reference value)
Contact resistance
Operate (set*) time
Release (reset*) time
Bounce time
Max. operating frequency
Insulation resistance
Dielectric
withstand voltage
Impulse withstand voltage
Shock resistance
Endurance
Ambient temperature
Ambient humidity
Weight
SPDT
Vibration resistance
Text
PCB Signal Relay – G6E
Characteristics
Approved Standards
Contact Ratings
Contact form
-6
/operation.
1,500 VAC, 50/60 Hz for 1 min between coil and contacts
3 to 48 VDC
50 mΩ max.
5 ms max. (mean value: approx. 2.9 ms; 48 VDC type: approx. 2.4 ms)
5 ms max. (mean value: approx. 1.3 ms)
Operate: 3 ms max. (mean value: 0.37 ms)
Release: 3 ms max. (mean value: 1.12 ms)
Mechanical: 36,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
1,000 MΩ min. (at 500 VDC)
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
1,500 V (10 x 160 µs) (conforms to FCC Part 68)
Destruction: 10 to 55 to 10 Hz, 2.5mm single amplitude (5mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 1.65mm single amplitude (3.3mm double amplitude)
Destruction: 1,000 m/s
Malfunction: 300 m/s
Mechanical: 100,000,000 operations min. (at 36,000 operations/hr)
Electrical: 100,000 operations min. (0.4 A at 125 VAC resistive load;
0.2 A at 125 VAC inductive load)
500,000 operations min. (2 A at 30 VDC resistive load; 1 A at 30 VDC inductive load)
200,000 operations min. (3 A at 30 VDC resistive load)
Operating: -40°C to 70°C (with no icing)
5% to 85%
Approx. 2.7 g
Resistive load (cosø = 1)
0.4 A at 125 VAC; 2 A at 30 VDC
Ag (Au–clad)
3 A
250 VAC, 220 VDC
3 A
50 VA, 60 W
10µ A at 10m VDC
Coil ratings
2
2
0.2 A, 250 VAC (general use)
0.6 A, 125 VAC (general use)
2 A, 30 VDC (resistive)
0.6 A, 125 VDC (resistive, Ag contact only)
Inductive load (cosø = 0.4; L/R = 7 ms)
0.2 A at 125 VAC; 1 A at 30 VDC
3 A
25 VA, 30 W
Contact ratings
187