AGQ20012 PANASONIC EW, AGQ20012 Datasheet

SIGNAL RELAY, DPDT, 12VDC, 1A, THD

AGQ20012

Manufacturer Part Number
AGQ20012
Description
SIGNAL RELAY, DPDT, 12VDC, 1A, THD
Manufacturer
PANASONIC EW
Datasheet

Specifications of AGQ20012

Contact Configuration
DPDT
Contact Current Max
1A
Contact Voltage Ac Nom
125V
Contact Voltage Dc Nom
30V
Coil Voltage Vdc Nom
12V
Coil Type
DC, Monostable
Coil Current
11.7mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
AGQ20012
Quantity:
9 888
ORDERING INFORMATION
Contact arrangement
2: 2 Form C
Operating function
0: Single side stable
1: 1 coil latching
6: High sensitivity single side
Type of operation
0: Standard type (B.B.M.)
Terminal shape
Nil:
A:
S:
Nominal coil voltage (DC)
1H: 1.5V 03: 3V 4H: 4.5V 06: 6V 09: 9V
12: 12V 24: 24V
Packing style
Nil:
X:
Z:
Compliance with RoHS Directive
stable type
Standard PC board terminal
Surface-mount terminal A type
Surface-mount terminal S type
Tube packing
Tape and reel packing (picked from 1/2/3/4 pin side)
Tape and reel packing (picked from 5/6/7/8 pin side)
AGQ 2
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
0
FEATURES
1. Compact flat body saves space
2. High sensitivity single side stable
3. Outstanding surge resistance.
4. The use of twin crossbar contacts
5. Increased packaging density
High sensitivity of nominal
operating power 100mW is
With a small footprint of 10.6 mm (L)
7.2 mm (W)
(W)
very short height of 5.2 mm
(Standard PC board type.)
type (Nominal operating power:
100mW) is available
Surge breakdown voltage between
contacts and coil:
2,500 V 2 10 s (Telcordia)
Surge breakdown voltage between
open contacts:
1,500 V 10 160 s (FCC part 68)
ensures high contact reliability.
AgPd contact is used because of its
good sulfide resistance. Adopting low-
gas molding material. Coil assembly
molding technology which avoids
generating volatile gas from coil.
Due to highly efficient magnetic circuit
design, leakage flux is reduced and
changes in electrical characteristics
from components being mounted
achieved. Ultra small
for space savings, it also has a
package & Flat type
.417 inch (L)
.283 inch
.205
inch.
6. Nominal operating power: 140 mW
7. Outstanding vibration and shock
8. Sealed construction allows
TYPICAL APPLICATIONS
1. Telephone switchboard
2. Telecommunications equipment
3. Security
4. Measurement equipment
5. Consumer electronic and audio
GQ RELAYS (AGQ)
close-together are minimized. This all
means a packaging density higher
than ever before.
resistance.
Functional shock resistance: 750 m/s
Destructive shock resistance:
1,000 m/s
Functional vibration resistance:
10 to 55 Hz (at double amplitude of
3.3 mm
Destructive vibration resistance:
10 to 55 Hz (at double amplitude of
5 mm
automatic washing.
visual equipment
.197
.130
2
inch)
inch)
GQ (AGQ)
TESTING
2

Related parts for AGQ20012

AGQ20012 Summary of contents

Page 1

... Due to highly efficient magnetic circuit design, leakage flux is reduced and changes in electrical characteristics from components being mounted GQ (AGQ) GQ RELAYS (AGQ) close-together are minimized. This all means a packaging density higher than ever before. 6. Nominal operating power: 140 mW 7. Outstanding vibration and shock resistance ...

Page 2

... DC 12V DC 24V DC *Pulse drive (JIS C 5442-1996) Single side stable Part No. AGQ2001H AGQ20003 AGQ2004H AGQ20006 AGQ20009 AGQ20012 AGQ20024 Single side stable Part No. AGQ200 1H AGQ200 03 AGQ200 4H AGQ200 06 AGQ200 09 AGQ200 12 AGQ200 24 Single side stable Part No. AGQ200 1HZ AGQ200 03Z ...

Page 3

High sensitivity single side stable type Nominal coil Set voltage voltage ( 1. 4.5V DC 80%V or less of 10%V or more nominal voltage* nominal voltage (Initial) ...

Page 4

... Coil applied voltage Ambient temperature characteristics Tested sample: AGQ200A4H, 6 pcs Drop-out voltage 10 -40 - -10 Pick-up voltage -20 -30 -40 -50 120 130 9-(2). Influence of adjacent mounting Tested sample: AGQ20012, 6 pcs Pick-up voltage -10 10 OFF OFF 5 Drop-out voltage 0 OFF -5 - .079 .157 .236 .315 .394 .472 ...

Page 5

... In addition, excessive chucking pressure 3.150 .039 dia. to the pinpoint of the relay should be also 330 2 dia. avoided. 12.992 .079 dia. For general cautions for use, please refer to the “Cautions for use of Signal Relays” or “General Application Guidelines”. GQ (AGQ) B portion. ...