Notice: Artisan Controls Corporation assumes no responsibility for customers applications or product design. The information and data contained herein is
the sole and exclusive property of Artisan Controls Corporation. Any duplication, misuse, or conversion of this information without the express written
consent of Artisan Controls Corporation is illegal and will result in damages including court costs and attorney fees being assessed against the party
misusing this property
External Timing Resistor Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mechanical & Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Timing Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
The left hand column lists five values of external resistors: 0, 1 meg, 3 meg,
5 meg, and 10 meg, and across the top are listed the five model dash
numbers, 1 through 5. To illustrate how the chart works assume that timing
range -3 has been selected. Under the -3 column are the times that relate
to the five values of external resistors. For an external resistor equal to 0
ohms, the interval would be 2 seconds. With 1 meg ohm, 100 seconds and
so forth up to 10 meg ohms where the timing interval is 1000 seconds. If a
3 meg ohm potentiometer were connected across the external timing
resistor terminals, you could expect, as a minimum, a range of interval timing
from 2 to 300 seconds.
Tel: 973-598-9400 • Fax: 973-598-9410 • Toll Free: 800-457-4950
Artisan Controls Corporation, 111 Canfield Ave., Bldg B15-18, Randolph, NJ, 07869, USA
Operating
Voltage
Load
Terminals 4 & 5
omitted on fixed
time units
V
Solid State Timers and Controllers
Off
Off
I S I T O U R W E B S I T E A T
The model 4300 series provides a load circuit with operating voltage for a
predetermined amount of time each time the operating voltage is applied. The
operating voltage must be present for the duration that exceeds the preset interval
timing period. The 4300 series is available in both AC and DC models and controls
output load circuits to 1 ampere. Fixed or adjustable timing interval periods are
available. Adjustable models have the interval time preset by adding a resistor
across terminals 4 & 5.
On
On
0.25 Dia. Mtg. Hole
4300
2.0 SQ.
Full Interval Timing
Period, power applied
longer than timing period
100 Ohm Resistor and diode
are installed in DC units for
switching inductive loads
Load
: www.artisancontrols.com
Power
Input
DC units only
External
Polarity for
Resistor
(Ohms)
0.25 Q.D. Terminals
10 Meg
1 Meg
3 Meg
5 Meg
0
0.1
-1
12
20
30
4
1.25 Max
Truncated Interval
period, power
applied less than
timing period
0.82
150
300
-2
Timing Module
30
90
1
DASH NO.
Interval
1,000
-3
100
300
500
2
1,500
2,500
5,000
-4
500
10
2,700
4,500
8,000
-5
900
30