80.21.0.240.0000 FINDER, 80.21.0.240.0000 Datasheet - Page 4

ON PULSE TIMER

80.21.0.240.0000

Manufacturer Part Number
80.21.0.240.0000
Description
ON PULSE TIMER
Manufacturer
FINDER

Specifications of 80.21.0.240.0000

Contact Configuration
SPDT
Nom Input Voltage
240V
Delay Time Range
0.1s To 20h
Adjustment Type
Screwdriver Slot
Relay Mounting
DIN Rail
Svhc
No SVHC (15-Dec-2010)
Contact Current Ac Max
16A
Contact Voltage Ac
RoHS Compliant
Timing Adjustment
Screwdriver Slot
Rohs Compliant
Yes
Features
Mono-function timer range
80.61 - True OFF delay, multi-voltage
80.82 - Star-Delta timer, multi-voltage
80.61 / 80.82
Screw terminal
F
S
4
Contact specification
Contact configuration
Rated current/Maximum peak current
Rated voltage/Maximum switching voltage V AC
Rated load AC1
Rated load AC15 (230 V AC)
Single phase motor rating (230 V AC)
Breaking capacity DC1: 30/110/220 V
Minimum switching load
Standard contact material
Supply specification
Nominal voltage (U
Rated power AC/DC
Operating range
Technical data
Specified time range
Repeatability
Recovery time
Minimum control impulse
Setting accuracy-full range
Electrical life at rated load in AC1
Ambient temperature range
Protection category
Approvals (according to type)
17.5 mm wide
Rotary range selector, and timing trimmer
Four time scales from 0.1s to 20s (type 80.61)
Six time scales from 0.1s to 20min (type 80.82)
High input/output isolation
35 mm rail (EN 50022) mount
OR
EE
80.82
“General technical information” page V
UL H
17.5
ORSEPOWER AND
80.61
17.5
N
)
P
ILOT
D
V AC (50/60 Hz)
60.8
UTY RATINGS
VA (50 Hz)/W
mW (V/mA)
cycles
V DC
kW
AC
DC
VA
VA
ms
ms
°C
%
%
A
A
BI: True Off Delay
Multi-voltage
Mono-function
(0.1...1)s, (0.5...5)s, (1...10)s, (2...20)s
(without signal START)
Wiring diagram
< 0.6/ < 0.6
1 CO (SPDT)
8/0.3/0.12
300 (A1-A2)
(17...265)V
(17...265)V
N/-
300 (5/5)
–10…+50
A2
18 15 16
250/400
24…240
24...240
100·10
80.61
2000
8/15
AgNi
IP 20
≤ 50
400
0.3
± 1
± 5
A1
L/+
3
80 Series - Modular timers 6 - 8 A
SD: Star-Delta
(0.1...2)s, (1...20)s, (0.1...2)min, (1...20)min
Multi-voltage
Mono-function
Transfer time can be regulated (0.05…1)s
(without signal START)
2 NO (DPST-NO)
Wiring diagram
(10.2...265)V
(10.2...265)V
500 (12/10)
< 1.3/ < 0.8
6/0.2/0.12
N/-
–10…+50
A2
17 18 28
250/400
12...240
12...240
80.82
60·10
6/10
1500
AgNi
IP 20
≤ 50
300
A1
± 1
± 5
L/+
3

Related parts for 80.21.0.240.0000