R64-11AD10-4 NTE ELECTRONICS, R64-11AD10-4 Datasheet - Page 2

TIME DELAY RELAY DPDT, 100MIN, 240VAC/DC

R64-11AD10-4

Manufacturer Part Number
R64-11AD10-4
Description
TIME DELAY RELAY DPDT, 100MIN, 240VAC/DC
Manufacturer
NTE ELECTRONICS
Series
R64r
Type
Multifunctional Time Delay Relayr
Datasheet

Specifications of R64-11AD10-4

Contact Configuration
DPDT
Nom Input Voltage
240V
Delay Time Range
0.1s To 100min
Timing Adjustment
Knob
Relay Mounting
Plug In
Relay Terminals
8 Pin Octal
Coil Voltage Vdc Nom
240V
Product
General Purpose / Industrial Relays
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
R64 Series (Continued)
DIP Switch Layout
Timing Function Descriptions
Delay On Operate
8−Pin Type: Output relay is energized at the completion of the time
interval which is initiated by the application of input voltage.
11−Pin Type: Same as above except, closing the control switch after
time out will de−energize the relay and reset the timer. Opening the
switch will initiate another time interval. Closing the control switch
during timing will reset the time to zero and inhibit timing until opened
again.
Interval On (Input Controlled)
8−Pin Type: Output relay is energized by the application of input
voltage. The time interval is initiated at the sme time with the relay
de−energize at the completion of the time interval.
11−Pin Type: Same as above. Closing the control switch will have no
effect on timing or the state of the relay.
Recycler (Initially Off)
8−Pin Type: Output relay will begin cycling at a 50% duty cycle with
the application of input power. The initial state of the relay will be
de−energized.
11−Pin Type: Same as above except, closing the control switch will
de−energize the relay and inhibit timing until it is once again opened,
at whice time it will start from zero time.
Recycler (Initially On)
8−Pin Type: Output relay will begin cycling at a 50% duty cycle with
the application of input power. The initial state of the relay will be
energized.
11−Pin Type: Same as above except, closing the control switch will
energize the relay and inhibit timing until it is once again opened, at
which time it will start from zero time.
68
DIP Switch
Setting
Delay On Operate
Interval On
(Input Controller)
Recycler
(Initially Off)
Recycler
(Initially On)
Timing Function Switch Settings
Function
Note: The solid blocks in the DIP switch diagrams indicate the switch positions.
On
1
For example, all the switches are “off” in the diagram above.
NTE Electronics, Inc.
DIP Switch
Function Setting
Setting
2
Delay On Release
Inverted Delay
On Release
Interval On
(Switch Controlled)
Interval Off
Function
3
D
Voice (973) 748−5089
4
DIP Switch
Delay On Release
11−Pin Only: Output relay is energized by the closing of the control
switch with the input applied or the application of input voltage with the
control switch already closed. The time interval will be initiated by the
opening of the control switch with the relay de−energized at the
completion of the time interval. Closing the control switch after time out
will energize the relay in preparation for another time interval. Closing
the switch during timing will reset the time to zero and inhibit timing until
opened again.
Inverted Delay On Release
8−Pin Type: No Time Delay − Instantly On
11−Pin Type: Output relay will energize with the application of the input
voltage when the control switch is open. Control switch closing will
de−energize the relay. A timing interval will be initiated with the opening
of the control switch, at the completion of which the relay will energize.
With the control switch closed upon application of input voltage, the
relay will wait until the control switch is opened to initiate a time interval
after which the relay will energize. Closing of the control switch during
timing will reset the time to zero and inhibit timing until opened again.
Interval On (Switch Controlled)
11−Pin Only: Output relay is energized by the application of input
voltage with the control switch closed or the closing of the control switch
with the input applied. Immediately upon either, timing is initiated with
the relay de−energized at the completion of the time interval. Closing
the control switch after time out will reset the timer, energize the relay,
and initiate another time interval. Closing the control switch during
timing will have no effect on timing or the state of the relay.
Interval Off
11−Pin Only: Output relay will initially be energized with the application
of the input voltage when the control switch is open. Control switch
closing will de−energize the relay and start a time interval. At the
completion of the time interval, the relay will energize. With the control
switch closed upon application of input voltage, a time interval will be
initiated after which the relay will energize. Closing of the contol switch
during timing will have no effect on timing or the state of the relay.
Setting
5
0.1 − 1.0 Seconds
1.0 − 10 Seconds
10 − 100 Seconds
Time Setting
Timing Range
D
FAX (973) 748−6224
Timing Range Switch Settings
6
7
DIP Switch
Setting
D
http://www.nteinc.com
1.0 − 10 Minutes
10 − 100 Minutes
0.1 − 1.0 Minutes
Timing Range

Related parts for R64-11AD10-4