TR-51628-09 MACROMATIC CONTROLS, TR-51628-09 Datasheet - Page 4

TIME DELAY RELAY, DPDT, 120SEC, 24VAC/DC

TR-51628-09

Manufacturer Part Number
TR-51628-09
Description
TIME DELAY RELAY, DPDT, 120SEC, 24VAC/DC
Manufacturer
MACROMATIC CONTROLS
Datasheet

Specifications of TR-51628-09

Contact Configuration
DPDT
Nom Input Voltage
24V
Delay Time Range
1.2s To 120s
Timing Adjustment
Knob
Relay Mounting
Plug In
Relay Terminals
11 Pin Octal
No. Of Pins
11
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage Tolerance:
AC Operation:
DC Operation:
Load (Burden):
2 VA
Setting Accuracy:
Maximum Setting (Adjustable): +5%, -0%
Minimum Setting (Adjustable):
Fixed Time Delay:
Repeat Accuracy (constant voltage and temperature):
> 2 Seconds Delay
0.1 - 2 Seconds Delay
Reset Time:
On Delay/Interval/Repeat Cycle/Delayed Interval: 0.1 Seconds
Off Delay/Single Shot/Watchdog/
Triggered Delayed Interval: 0.04 Seconds
Start-up Time:
(Time from when power is applied until unit is timing)
120 & 240V units
12, 24 & 48V units
Maintain Function Time:
(Time unit continues to time after power is removed)
0.01 Seconds for all units
Temperature:
12-120V Input Voltage: -28
240V Input Voltage:
Dimensions
Application Data
1/09
+10/-15% of nominal at 50/60 Hz.
+10/-15% of nominal.
> 2 Seconds
0.1 - 2 Seconds
0.05 Seconds
0.08 Seconds
-28
(60)
2.4
+0.1%
+2%
o
o
to 65
to 50
+0%, -50%
o
o
C (-18
C (-18
+1%
+5%
o
o
to 150
to 122
(43)
1.7
o
o
F)
F)
Insulation Voltage:
2,000 volts
Output Contacts:
DPDT 10A @ 240V AC/30V DC,
1/2HP @ 120/240V AC (N.O.), 1/3HP @ 120/240V AC (N.C.)
B300 & R300; AC15 & DC13
Life:
Mechanical: 10,000,000 operations
Full Load: 100,000 operations
Compatibility:
On all units triggered by input voltage or by a control switch,
do not use a solid state switch to initiate the timing sequence-
problems with leakage current could occur. On all units with a
power trigger, do not use a solid state switch with leakage
current exceeding 0.5ma. Contact Macromatic Controls for
additional information.
Triggering Off Delay, Single Shot or Watchdog Units:
Timing sequence must be initiated only after input voltage is
applied to unit. Minimum required trigger switch closure time
is 0.1 seconds.
Approvals:
File #E109466
TIME DELAY RELAYS
Non-Programmable Plug-in
File #LR45565
Application Data & Dimensions
(74)
2.9
(89)
3.5
EN60947-1, EN60947-5-1
EMC Directives
Low Voltage &
Inches (Millimeters)
All Dimensions in
File #E109466
appropriate
socket
with
63