H3DE-H Omron, H3DE-H Datasheet - Page 3

Solid State Timer

H3DE-H

Manufacturer Part Number
H3DE-H
Description
Solid State Timer
Manufacturer
Omron
Datasheet

Specifications of H3DE-H

Contact Configuration
SPCO
Nom Input Voltage
230V
Timing Adjustment
Screwdriver Slot
Relay Mounting
DIN Rail
Length/height, External
79mm
Voltage Ac
250V
External Width
22.5mm
Voltage Rating Vdc
30V
■ Characteristics
Note: For reference:
Accuracy of operating time
Setting error
Influence of voltage
Influence of temperature
Insulation resistance
Dielectric strength
Impulse withstand voltage
Noise immunity
Static immunity
Vibration resistance
Shock resistance
Life expectancy
EMC
Degree of protection
Weight
A maximum current of 0.15 A can be switched at 125 VDC (cos =1).
A maximum current of 0.1 A can be switched if L/R is 7 ms.
In both cases, a life of 100,000 operations can be expected.
The minimum applicable load is 100 mA at 5 VDC (failure level: P).
100 M min. at 500 VDC
Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC (50/60 Hz) for 1
min.
Between control output terminals and operating circuit: 2,000 VAC (50/60 Hz) for 1 min.
Between contacts not located next to each other: 1,000 VAC (50/60 Hz) for 1 min.
3 kV (or 1 kV for 24/48 VAC/VDC models) (between power supply terminals)
4.5 kV (or 1.5 kV for 24/48 VAC/VDC models) (between current-carrying metal parts and exposed non-current-
carrying metal parts)
Square-wave noise generated by noise simulator (pulse width: 100 ns/1 s, 1-ns rise) 1.5 kV (between power
supply terminals)
Malfunction: 4 kV
Destruction: 8 kV
Malfunction: 0.5-mm single amplitude at 10 to 55 Hz
Destruction: 0.75-mm single amplitude at 10 to 55 Hz
Malfunction: 100 m/s
Destruction: 1,000 m/s
Mechanical: 10 million operations min. (under no load at 1,200 operations/h)
Electrical:
(EMI)
Emission Enclosure:
Emission AC Mains:
Harmonic Current:
Voltage Fluctuation and Flickering:
(EMS)
Immunity ESD:
Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
Immunity Burst:
Immunity Surge:
IP30 (IP20 for terminal block)
Approx. 120 g
1% max. of FS ( 1% 10 ms max. at 1.2-s range)
10%
0.5% max. of FS ( 0.5% 10 ms max. at 1.2-s range)
2% max. of FS ( 2%
0.05 s max. of FS
100,000 operations min. (5 A at 250 VAC, resistive load at 1,200 operations/h)
2
2
10 ms max. at 1.2-s range)
Solid-state Power OFF-delay Timer
EN61812-1
EN55011 Group 1 class A
EN55011 Group 1 class A
EN61000-3-2
EN61000-3-3
EN61812-1
EN61000-4-2: 6 kV contact discharge (level 3)
EN61000-4-4: 2 kV power port and output port (level 3)
EN61000-4-5: 2 kV common mode (level 3)
8 kV air discharge (level 3)
1 kV control port with capacitive clamp (level 3)
1 kV differential mode (level 3)
H3DE-H
B-77

Related parts for H3DE-H